David James Rowe

Dr. David James Rowe


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2024 in APL Photonics
Verified
Journal Article
Open access
PDF file
CMColin J. Mitchell
Colin J. Mitchell
THTianhui Hu
Tianhui Hu
SSShiyu Sun
Shiyu Sun
CSCallum J. Stirling
Callum J. Stirling
MNMilos Nedeljkovic
Milos Nedeljkovic
DRDavid James Rowe
David James Rowe
Silicon photonics is one of the most dynamic fields within photonics, and it has seen huge progress in the last 20 years, addressing applications in data centers, autonomous cars, and sensing. It is mostly focused on the telecommunications wavelength range (1.3 and 1.55 µm), where silicon becomes transparent. In this range, there are excellent light sources and photodetectors, as well as optical fibers operating with extremely low losses and dispersion. It is a technology that hugely benefits from the availability of complementary metal–oxide–semiconductor (CMOS) fabrication infrastructure and techniques used for microelectronics. Silicon and germanium, as another CMOS compatible group IV material, are transparent beyond the wavelength of 2 µm. The mid-IR wavelength range (2–20 µm) is of particular importance as it contains strong absorption signatures of many molecules. Therefore, Si- and Ge-based platforms open up the possibility of small and cost-effective sensing in the fingerprint region for medical and environmental monitoring. In this paper, we discuss the current mid-IR silicon photonics landscape, future directions, and potential applications of the field.

4 August 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
DRDavid James Rowe
David James Rowe
DSDavid Smith
David Smith
JWJames Wilkinson
James Wilkinson
Mid-infrared (MIR) spectroscopy is a powerful tool for characterising the vibrations of molecular bonds and is therefore ideal for label-free detection of chemical species. Recent research into thin-film deposition and etching techniques for mid-infrared materials shows potential for realising miniaturised bedside biosensors for clinical diagnostics exploiting MIR spectroscopy, to replace laboratory based-techniques. However, lack of refractive index information for commonly encountered biological media and analytes hampers optimisation of biosensor performance for maximum sensitivity, especially for devices exploiting evanescent spectroscopy. Here we present refractive index data for human whole blood and several aqueous solutions of general interest to the clinical community: anticoagulants, analgesics and buffers. The refractive indices are generally dominated by the water content of each sample and the whole blood spectra exhibit additional strong features due to protein content. Furthermore, we present a generalised method for extracting complex refractive indices of aqueous solutions in the mid-infrared region using conventional attenuated total reflection Fourier transform spectroscopy (ATR-FTIR) without the need for collimated or polarised incident light, as is required for existing methods.

19 November 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Callum LittlejohnsCallum Littlejohns
Callum Littlejohns
DRDavid James Rowe
David James Rowe
HDHan Du
Han Du
KLKe Li
Ke Li
WZWeiwei Zhang
Weiwei Zhang
GRGraham Reed
Graham Reed
The field of silicon photonics has experienced widespread adoption in the datacoms industry over the past decade, with a plethora of other applications emerging more recently such as light detection and ranging (LIDAR), sensing, quantum photonics, programmable photonics and artificial intelligence. As a result of this, many commercial complementary metal oxide semiconductor (CMOS) foundries have developed open access silicon photonics process lines, enabling the mass production of silicon photonics systems. On the other side of the spectrum, several research labs, typically within universities, have opened up their facilities for small scale prototyping, commonly exploiting e-beam lithography for wafer patterning. Within this ecosystem, there remains a challenge for early stage researchers to progress their novel and innovate designs from the research lab to the commercial foundries because of the lack of compatibility of the processing technologies (e-beam lithography is not an industry tool). The CORNERSTONE rapid-prototyping capability bridges this gap between research and industry by providing a rapid prototyping fabrication line based on deep-UV lithography to enable seamless scaling up of production volumes, whilst also retaining the ability for device level innovation, crucial for researchers, by offering flexibility in its process flows. This review article presents a summary of the current CORNERSTONE capabilities and an outlook for the future.

13 June 2018 in Optics Letters
Verified
Journal Article
Closed access
PDF file
VMVinita Mittal
Vinita Mittal
MNMilos Nedeljkovic
Milos Nedeljkovic
DRDavid James Rowe
David James Rowe
Ganapathy Senthil MuruganGanapathy Senthil Murugan
Ganapathy Senthil Murugan
JWJames Wilkinson
James Wilkinson
We demonstrate the integration of paper fluidics with mid-infrared (MIR) chalcogenide waveguides to introduce liquid samples to the waveguide evanescent field for analysis. Spectroscopy of model analytes (water and isopropyl alcohol) having well-defined mid-IR absorptions, on a ZnSe rib waveguide fabricated on silicon, is demonstrated in the wavelength range of 2.6–3.7 µm, showing their O-H and C-H stretching absorptions. The results are compared with a theoretical waveguide model, achieving good agreement. It is concluded that the presence of paper in the evanescent field does not interfere with the waveguide measurements, opening up opportunities to combine low-cost paper-based fluidics and integrated photonic technologies.

23 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
WAWaseem Ahmed
Waseem Ahmed
Aneesh Vincent VeluthandathAneesh Vincent Veluthandath
Aneesh Vincent Veluthandath
DRDavid James Rowe
David James Rowe
JMJens Madsen
Jens Madsen
HCHoward W. Clark
Howard W. Clark
Ganapathy Senthil MuruganGanapathy Senthil Murugan
Ganapathy Senthil Murugan
The authors of this study developed the use of attenuated total reflectance Fourier transform infrared spectroscopy (ATR–FTIR) combined with machine learning as a point-of-care (POC) diagnostic platform, considering neonatal respiratory distress syndrome (nRDS), for which no POC currently exists, as an example. nRDS can be diagnosed by a ratio of less than 2.2 of two nRDS biomarkers, lecithin and sphingomyelin (L/S ratio), and in this study, ATR–FTIR spectra were recorded from L/S ratios of between 1.0 and 3.4, which were generated using purified reagents. The calibration of principal component (PCR) and partial least squares (PLSR) regression models was performed using 155 raw baselined and second derivative spectra prior to predicting the concentration of a further 104 spectra. A three-factor PLSR model of second derivative spectra best predicted L/S ratios across the full range (R2: 0.967; MSE: 0.014). The L/S ratios from 1.0 to 3.4 were predicted with a prediction interval of +0.29, −0.37 when using a second derivative spectra PLSR model and had a mean prediction interval of +0.26, −0.34 around the L/S 2.2 region. These results support the validity of combining ATR–FTIR with machine learning to develop a point-of-care device for detecting and quantifying any biomarker with an interpretable mid-infrared spectrum.

12 July 2021 in Plastic and Reconstructive Surgery - Global Open
Verified
Journal Article
Open access
CCChristopher Cheng
Christopher Cheng
GKGrzegorz J. Kwiecien
Grzegorz J. Kwiecien
DRDavid James Rowe
David James Rowe
JGJames R. Gatherwright
James R. Gatherwright
KCKyle J. Chepla
Kyle J. Chepla
Summary: Injectable drug use in the upper extremity often leads to chronic wounds complicated by osteomyelitis. Conventional reconstructive options are often not feasible and/or are contraindicated in this patient population. We have started using a synthetic, biodegradable temporizing matrix (BTM) for the treatment of these patients. We hypothesize that BTM is a safe, low-risk, and low-morbidity alternative reconstructive option. We report outcomes after staged debridement and BTM application followed by split-thickness skin grafting for two patients with large, chronic bilateral forearm wounds with concomitant osteomyelitis confirmed by MRI and biopsy. No acute surgical complications were encountered and at a mean follow-up of 13 months, both patients had maintained stable soft-tissue coverage. Reconstruction using BTM is a novel treatment option that can simplify the reconstruction, reduce donor-site morbidity, and optimize success for patients with chronic wounds resulting from injectable drug use. Initial outcomes are promising; however, further comparative studies are needed to better evaluate long-term outcomes of this technique.