1 January 2016 in Plastic and Reconstructive Surgery
Background: Insufficient soft-tissue coverage following total knee arthroplasty jeopardizes prosthesis retention and may lead to significant complications. The aim of this study was to evaluate the natural history of total knee arthroplasty following flap reconstruction of soft-tissue defects. Methods: A retrospective review of patients treated with flaps after failed total knee arthroplasty between 1998 and 2013 was conducted. Patients with preexisting soft-tissue defects who required reactive flap reconstruction were included in group 1. Patients with no preexisting soft-tissue defects, but with extensive débridement during revision total knee arthroplasty requiring immediate proactive flap coverage, were included in group 2. Results: Fifty-eight patients in group 1 were treated with 86 flaps, and 15 patients in group 2 were treated with 17 flaps. Mean length of follow-up was 67.0 and 54.7 months, respectively (p = 0.21). Flap-related complications and number of subsequent flap revisions were comparable in both groups. Patients in group 1 had a higher rate of implant reinfection (58 percent versus 27 percent; p < 0.05), amputations (25 percent versus 0 percent; p < 0.05), and subsequent prosthesis revisions (2.2 versus 0.9; p < 0.05). Functional joint was preserved in 54 percent and 80 percent of cases, respectively. Mean gain in range of motion and quality of life were significantly better in group 2 (p < 0.05). Conclusions: Early proactive soft-tissue coverage of total-knee arthroplasty is critical to long-term success. In cases where reactive treatment is required, significantly worse outcomes and a high rate of complications should be expected. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, III.
12 July 2021 in Plastic and Reconstructive Surgery - Global Open
Summary: Injectable drug use in the upper extremity often leads to chronic wounds complicated by osteomyelitis. Conventional reconstructive options are often not feasible and/or are contraindicated in this patient population. We have started using a synthetic, biodegradable temporizing matrix (BTM) for the treatment of these patients. We hypothesize that BTM is a safe, low-risk, and low-morbidity alternative reconstructive option. We report outcomes after staged debridement and BTM application followed by split-thickness skin grafting for two patients with large, chronic bilateral forearm wounds with concomitant osteomyelitis confirmed by MRI and biopsy. No acute surgical complications were encountered and at a mean follow-up of 13 months, both patients had maintained stable soft-tissue coverage. Reconstruction using BTM is a novel treatment option that can simplify the reconstruction, reduce donor-site morbidity, and optimize success for patients with chronic wounds resulting from injectable drug use. Initial outcomes are promising; however, further comparative studies are needed to better evaluate long-term outcomes of this technique.
15 October 2017 in Journal of Reconstructive Microsurgery
Background The purpose of this study was to: (1) evaluate the mechanism of lymph drainage through a vascularized lymph node (VLN) flap, and (2) investigate if the number of VLNs impacts lymph transit time through the flap. Methods Twenty-seven axillary VLN flaps were elevated in 14 Sprague-Dawley rats and divided into three groups (n = 9 each) based on the number of lymph nodes present: group 1 (0-VLNs), group 2 (2-VLNs), and group 3 (4-VLNs). Indocyanine green (n = 8/group) and Alexa680-albumin (n = 1/group) were injected into the edge of flaps and the latency period between injection and fluorescence in the axillary vein was recorded. Stereomicroscopic fluorescent lymphography was performed to directly visualize lymphatic transit through VLNs. Results Fluorescence was detected in the axillary vein after 229s [47–476], 79s [15–289], and 56s [16–110] in group 1, 2, and 3, respectively (p < 0.01). There was a negative correlation between the number of VLNs in the flap and the latency period (r = -0.59; p < 0.05). Median flap weights were comparable in group 1, 2, and 3 (258 mg [196–349], 294 mg [212–407], 315 mg [204–386], respectively; p = 0.54). Stereoscopic lymphography allowed direct visualization of lymphatic fluid transit through VLNs. Conclusion Lymphatic fluid in VLN flaps drains into the venous system mainly by passing through the afferent lymphatics and lymph nodes. A secondary mechanism appears to be the diffusion of fluid into the venous system via intratissue lymphaticovenous connections created during flap elevation. Increasing the number of lymph nodes in the flap is associated with a more rapid transit of fluid.
1 November 2013 in Plastic and Reconstructive Surgery
11 January 2022 in Microsurgery
2 December 2022 in Journal of Hand Surgery Global Online
Flexor carpi radialis tendinitis is a condition that almost exclusively affects the distal aspect of the tendon where it lies in a tight fibro-osseous tunnel. Tendinitis of the proximal aspect of the tendon at its myotendinous junction is extremely rare. Herein, we present a single case of calcific tendinitis of the flexor carpi radialis tendon at its myotendinous junction in a throwing athlete. Diagnostic challenges and treatments are discussed.