Andreas Götz

Mr. Andreas Götz

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JHJennifer Huling
Jennifer Huling
AGAndreas Götz
Andreas Götz
NGNiels Grabow
Niels Grabow
SISabine ILLNER
Sabine ILLNER
This paper details the development and testing of the GIFT macro, which is a freely available program for ImageJ for the automated measurement of fiber diameters in SEM images of electrospun materials. The GIFT macro applies a validated method which distinguishes fiber diameters based on distance frequencies within an image. In this work, we introduce an applied version of the GIFT method which has been designed to be user-friendly while still allowing complete control over the various parameters involved in the image processing steps. The macro quickly processes large data sets and creates results that are reproducible and accurate. The program outputs both raw data and fiber diameter averages, so that the user can quickly assess the results and has the opportunity for further analysis if desired. The GIFT macro was compared directly to other software designed for fiber diameter measurements and was found to have comparable or lower average error, especially when measuring very small fibers, and reduced processing times per image. The macro, detailed instructions for use, and sample images are freely available online (https://github.com/IBMTRostock/GIFT). We believe that the GIFT macro is a valuable new tool for researchers looking to quickly, easily and reliably assess fiber diameters in electrospun materials.

30 August 2024 in Children
Verified
Journal Article
Open access
PDF file
BPBroder Poschkamp
Broder Poschkamp
SDSerge Dinkulu
Serge Dinkulu
TSThomas Stahnke
Thomas Stahnke
CBClara Marie Böckermann
Clara Marie Böckermann
EMEdith Mukwanseke
Edith Mukwanseke
NKNgoy-Janvier Kilangalanga
Ngoy-Janvier Kilangalanga
Background: Childhood blindness remains a neglected issue in eye care within low-income countries, with congenital and juvenile cataracts being the most common treatable causes. This study aims to investigate the factors influencing the management of congenital and juvenile bilateral cataracts, provide data on general outcomes and postoperative findings, and discuss treatment in a low-income country context. Methods: In this prospective study, data from clinical care were continuously entered into a database, and one follow-up examination of a cohort of 91 patients with congenital and juvenile bilateral cataracts in Kinshasa, Democratic Republic of the Congo, was conducted. Multiple factors that affect the first clinical presentation, the clinical management, and outcome were investigated. Results: Most patients (88.5%) who received medical treatment were identified by cataract finders. A patient’s presentation time was independent of the parent’s education, social status, income, and sex of the child. The median age at first presentation was 5.8 years (ranging from 0 days to 17.3 years). The best visual acuity outcomes were achieved by patients who underwent surgery during early childhood. According to WHO grades and on an eye level basis, 51.1% (93 out of 182 eyes) showed improvement, while 34.6% (63 eyes) had unchanged results post-surgery. Among the cases without improvement, 76.2% were blind prior to surgery. Postoperative findings were observed in 56% of the patients, with secondary cataracts being the most common, affecting 26.37% of the operated eyes. Conclusions: Optimal management of childhood cataracts involves early identification, efficient hospital infrastructure, high-quality medical care, and long-term follow up. In sub-Saharan Africa, this approach must be adapted to the context of available resources, which differs significantly from those in high- and middle-income countries.

7 February 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
GSGuido Schröder
Guido Schröder
EAEstelle Akl
Estelle Akl
JHJustus Frederick Hillebrand
Justus Frederick Hillebrand
AGAndreas Götz
Andreas Götz
TMThomas Mittlmeier
Thomas Mittlmeier
AGAenne Glass
Aenne Glass
Introduction: Comparative studies on Hounsfield units (HU) and bone volume fraction (BVF%) for the demonstration of cancellous bone density in the entire spine and in the various intravertebral regions are rare. The aim of the present study was to determine HU in various segments and sectional planes (sagittal, axial, coronary) of the spine and their description in the context of bone density measurement on micro-CT, as well as the significance of the values for bone loss and fracture risk. Materials/Methods: The spines of 11 body donors were analyzed by means of high-resolution spiral CT and micro-CT. Vertebral deformities were identified on sagittal reformations and classified. Cancellous bone density in the individual vertebrae from C3 to L5, expressed in HU, was measured on CT images (in all 242 vertebral bodies). For this purpose, a manually positioned ROI was established in mid-vertebral cancellous bone in the axial, sagittal, and coronary planes. Using a Jamshidi® needle, we obtained 726 specimens from prepared vertebrae extracted from three quadrants (QI: right-sided edge, QII: central, QIII: left-sided edge) and analyzed these on a micro-CT device (SKYSCAN 1172, RJL Micro & Analytic GmbH, Germany). The study design with multiple measurements was reflected by a General Linear Model Repeated Measures. The model was adjusted to the bone density values of both procedures (HU, BVF%) in the viewed sectional planes and quadrants for 22 vertebrae, with the predictors gender and fracture status, controlled for age and body mass index (BMI). Analysis of variance provided estimations of density values and comparisons of several subgroups. Results: All spines were osteoporotic. Both procedures revealed a significant reduction in cancellous bone density from C3 to L5 (p ≤ 0.018). Gender (p = 0.002) and fracture status (p = 0.001) have an impact on bone density: men have higher bone density values than women; cases with fewer fractures also have higher bone density values. CT revealed both effects (p = 0.002 for each) with greater clarity. HU on CT measurements in the axial plane showed higher density values than in the sagittal or coronary planes. CT measurement profiles along the spine as well as along the individual profiles of the 11 body donors were independent of the measured quadrants, but the micro-CT measurements were not. Discussion: The craniocaudal reduction in bone density was demonstrated in different degrees of clarity by the two procedures. Likewise, the procedure-related visualization of differences in cancellous bone density between genders, fracture groups, sectional planes, and quadrants indicates the need for a better understanding of the advantages of each procedure for patient-oriented approaches to the diagnosis of osteoporosis. Future research should be focused on the determination of standard values and their clinical application for the prevention and treatment of osteoporosis.

26 February 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
GSGuido Schröder
Guido Schröder
TMThomas Mittlmeier
Thomas Mittlmeier
PGPatrick Gahr
Patrick Gahr
SUSahra Ulusoy
Sahra Ulusoy
LHLaura Hiepe
Laura Hiepe
HSHans-Christof Schober
Hans-Christof Schober
Background: Trabeculae in vertebral bodies are unequally distributed within the cervical spine (CS), the thoracic spine (TS), and lumbar spine (LS). Such structures are also unequally distributed within the individual vertebrae. Exact knowledge of the microstructure of these entities could impact our understanding and treatment of fractures caused by osteoporosis and possibly improve surgical approaches. Appropriate investigations could help clarify the pathomechanisms of different forms of osteoporotic vertebral fractures, as well as different changes in morphological findings like the trabecular bone score (TBS). In the present study, we applied punctures to the craniocaudal and ventrocaudal directions and obtained cylinders of cancellous bone from the central portions and marginal regions of cervical vertebrae 5 and 6, thoracic vertebrae 8 and 12, and lumbar vertebrae 1 and 3. We systematically analyzed these samples to determine the bone volume fraction, trabecular thickness, separation, connectivity density, degree of anisotropy, and structure model index. Methods: Using an 8-gauge Jamshidi needle, we obtained samples from three quadrants (Q I: right margin; Q II: central; Q III: left margin) in the frontal and transverse plane and prepared these samples with a moist cloth in a 1.5 mL Eppendorf reaction vessel. The investigations were performed on a micro-CT device (SKYSCAN 1172, RJL Micro & Analytic Company, Karlsdorf-Neuthard, Germany). All collected data were analyzed using the statistical software package SPSS (version 24.0, IBM Corp., Armonk, NY, USA). Student’s t test, the Wilcoxon–Mann–Whitney test, the Chi-squared test, and univariate analysis were used for between-group comparisons. The selection of the test depended on the number of investigated groups and the result of the Shapiro–Wilk test of normal distribution. In the case of statistically significant results, a post hoc LSD test was performed. Results: In total, we obtained 360 bone samples from 20 body donors. The craniocaudal puncture yielded data of similar magnitudes for all investigated parameters in all three quadrants, with the highest values observed in the CS. Comparisons of the ventrodorsal and craniocaudal microstructure revealed a significantly lower trabecular density and a significantly higher degree of anisotropy in the craniocaudal direction. Conclusions: The results presented different distributions and behaviors of trabecular density, with lower density in the mid-vertebral region over the entire breadth of the vertebrae. Reduced trabecular density caused a higher degree of anisotropy and was, therefore, associated with a lower capacity to sustain biomechanical loads. Fractures in fish vertebrae were easily explained by this phenomenon. The different changes in these structures could be responsible, in part, for the changes in the TBS determined using dual-energy X-ray absorptiometry. These results confirm the clinical relevance of the TBS.

29 November 2024 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
AGAndreas Götz
Andreas Götz
SISabine Illner
Sabine Illner
NFNicklas Fiedler
Nicklas Fiedler
JSJulia Schubert
Julia Schubert
JOJan Oldenburg
Jan Oldenburg
KLKerstin Lebahn
Kerstin Lebahn
Background: Chronic venous insufficiency (CVI) is a common disease with a high prevalence. Incompetent venous valves are considered as one of the main causes. Besides compression therapy, various surgical therapies are practiced, whereby the reconstruction of valves is of central importance. There is an unmet clinical need, no valve prosthesis is commercially available to date. This work introduces two versions of a patented prosthetic bicuspid valve design made of electrospun thermoplastic silicone polycarbonate polyurethane (TSPCU) nanofiber leaflets attached in a nitinol stent, and their performance in static and pulsatile operation. Results: The valves mainly fulfill the requirements widely accepted in literature. Valves of both versions were functional in the physiological pressure range up to 50 mmHg with design specific differences. Conclusions: The here introduced design versions act as a platform technology and can be tailored for an intended implantation site. Evaluation of the original and modified valve concept demonstrated efficacy, with limitations at higher loads for original design. At the current state, the modification is preferable for fabrication, as one processing step is eliminated. Moreover, specific design recommendations could be drawn for valves of similar basic structure. Future work will focus on long-term performance and biocompatibility prior to the initiation of preclinical in vivo studies.

9 February 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
AGAndreas Götz
Andreas Götz
VSVolkmar Senz
Volkmar Senz
WSWolfram Schmidt
Wolfram Schmidt
DKDaniela Koper
Daniela Koper
NGNiels Grabow
Niels Grabow
SISabine ILLNER
Sabine ILLNER