Background—: Left ventricular assist device–supported patients are usually anticoagulated with a combination of aspirin and vitamin K antagonists. Long-term vitamin K antagonist therapy can be complicated by unstable international normalized ratio values and patient-related compliance problems. Therefore, direct thrombin inhibitors may represent an alternative to vitamin K antagonists. Methods and Results—: Thirty HeartWare ventricular assist device patients with stable renal function were planned for this prospective, randomized, open-label, single-center study. Patients were randomized to receive either phenprocoumon or dabigatran in addition to aspirin for long-term anticoagulation. Treatment duration was scheduled for 1 year and stopped after observation of a primary end point. Dabigatran dose was 110 and 75 mg BID in patients with normal or impaired renal function (glomerular filtration rate >80 mL/min or between 80 and 30 mL/min, respectively). The study was stopped prematurely for safety reasons after 16 patients (61±8 years, 1 female) were randomized. Thromboembolic events occurred in 4 subjects receiving dabigatran (50%) and in 1 receiving phenprocoumon (13%; P =0.28). No major bleeding was recorded, and no patient died during the study. Median time to treatment termination was significantly shorter in dabigatran patients (8.5 versus 12.0 months; P =0.015). Conclusions—: Thromboembolic events on dabigatran led to early termination of a randomized controlled trial of dabigatran versus phenprocoumon in left ventricular assist device patients. Clinical Trial Registration—: https://www.clinicaltrials.gov . Unique identifier: NCT02872649.
12 March 2014 in European Journal of Cardio-Thoracic Surgery
Avoiding full sternotomy and cardiopulmonary bypass (CPB) could significantly reduce the invasiveness of left ventricular assist device (LVAD) implantation. Therefore, we developed minimally invasive implant strategies for the Heartware® VAD (HVAD) and the Thoratec® HeartMate II (HMII) covering isolated LVAD implantation as well as concomitant valve procedures (aortic/tricuspid). We present the surgical techniques and the initial clinical experience. From February 2012 to March 2013, 27 patients (mean age 58 ± 8 years; male 85%; Ischemic Cardiomyopathy 63%; redo surgery 22%; Interagency Registry for Mechanically Assisted Circulatory Support Level I: 29%, II: 22%, III: 33%, IV–VII: 16%) underwent minimally invasive LVAD implantation at our department. Apical cannulation was performed via a left lateral minithoracotomy in HVAD patients (n = 20) or a left subcostal incision in HMII patients (n = 7). The outflow graft anastomosis was performed to the ascending aorta via a right minithoracotomy in the second intercostal space (n = 22) or the right subclavian artery (n = 2). If additional valve procedures (aortic/tricuspid) were necessary (n = 3), a hemisternotomy was performed to access the valve and perform the outflow graft anastomosis. Circulatory support for LVAD implantation was CPB (33%), extracorporeal membrane oxygenation (48%) or off-pump (19%). The minimally invasive approach was feasible in all patients with no need for conversions. Thirty-day and in-hospital mortality were 7.4 and 14.8%, respectively. In-hospital stay was 30.0 ± 22.5 days. One patient (4%) died during follow-up from pump thrombus formation. Three patients (11%) underwent surgical revision for bleeding. Minimally invasive LVAD implantation is feasible and safe. The very encouraging results obtained in this initial series justify a broad application of this technique.
18 March 2014 in European Journal of Cardio-Thoracic Surgery
Interagency Registry for Mechanical Assisted Circulatory Support (INTERMACS) Level I patients have the highest early mortality after ventricular assist device (VAD) implantation. This is determined by the exposure of patients in shock with acutely damaged end-organs and high catecholamine support to a significant surgical trauma. We report our experience with a bridge-to-bridge concept consisting of initial veno-arterial extracorporeal life support (ECLS) and deferral of VAD implantation to recovery of end-organ function in INTERMACS Level I patients. We reviewed the concept of initial ECLS implantation and deferral of VAD implantation to end-organ recovery in 22 consecutive patients (mean age 54 ± 14 years; 72.2% males; 50% ischemic cardiomyopathy; 100% INTERMACS Level I; 18.2% Heartmate II, 68.2% Heartware HVAD, 4.5% Heartware BiVAD, 9.1% DeBakey LVAD) receiving a VAD for refractory cardiogenic shock between June 2004 and February 2013. Study endpoints were end-organ recovery during ECLS and survival. ECLS significantly improved renal (creatinine 1.86 ± 0.91 vs 1.32 ± 0.52 mg/dl, P = 0.02), hepatic (aspartate aminotransferase 1426 ± 2176 vs 277 ± 259 U/l, P = 0.04; alanine aminotransferase 982 ± 1466 vs 357 ± 447 U/l, P = 0.04) and pulmonary functions (fraction of inspired oxygen 52 ± 18 vs 26 ± 23%, P < 0.01; positive end-expiratory pressure 7 ± 3 vs 5 ± 4 mbar, P = 0.02) over a period of 8 ± 7 days. Catecholamines could be reduced during ECLS (levosimendan 0.056 ± 0.085 vs 0.010 ± 0.032 μg/kg/min, P = 0.06; dobutamine 4.362 ± 5.268 vs 0.056 ± 0.097 μg/kg/min, P = 0.06; noradrenaline 0.408 ± 0.355 vs 0.056 ± 0.097 μg/kg/min, P < 0.01). Thirty-day and in-hospital mortality after VAD implantation were 4.5 and 9.1%, respectively, and 1-year survival was 86.4%. Preoperative patient optimization using ECLS improves outcomes of INTERMACS Level I patients receiving a permanent VAD.
1 January 2014 in The Journal of Heart and Lung Transplantation
The Impella 5.5 (Abiomed, USA) is a catheter-based micro-axial flow pump that has emerged as a vital tool in managing patients with cardiogenic shock (CS). Delivering up to 5.5 L/min of flow, it enables full left ventricular (LV) support with beneficial hemodynamic and metabolic effects. Its unique advantages include high-flow, antegrade circulatory support with the potential for prolonged usage, making it suitable for bridging to recovery or heart replacement therapies. This manuscript provides a comprehensive, structured guide for the clinical management of patients supported with the Impella 5.5. It outlines best practices for patient selection, surgical implantation techniques-most commonly via the axillary artery-perioperative management, anticoagulation strategies, and postoperative monitoring. Special emphasis is placed on complication management, including bleeding, hemolysis, right ventricular dysfunction, stroke, aortic valve injury, and vascular complications. Technologies like SmartAssist and Impella Connect are highlighted for their utility in real-time device monitoring and remote management. The manuscript also discusses a three-phase framework for recovery: hemodynamic stabilization, initiation of guideline-directed medical therapy (GDMT), and structured weaning protocols. Considerations for transitioning patients to heart transplantation or durable LVADs, as well as explant techniques, are detailed. The importance of multidisciplinary coordination-including a mechanical circulatory support (MCS) coordinator-is emphasized to ensure optimal patient outcomes. By synthesizing available evidence and institutional experience, this guide aims to standardize Impella 5.5 management, reduce complications, and improve outcomes in critically ill patients with advanced heart failure or CS.
Driveline infections (DLI) are common adverse events in left ventricular assist devices (LVADs), leading to severe complications and readmissions. The study aims to characterize risk factors for DLI readmission 2 years postimplant. This single‐center study included 183 LVAD patients (43 HeartMate II [HMII], 29 HeartMate 3 [HM3], 111 HVAD) following hospital discharge between 2013 and 2017. Demographics, clinical parameters, and outcomes were retrospectively analyzed and 12.6% of patients were readmitted for DLI, 14.8% experienced DLI but were treated in the outpatient setting, and 72.7% had no DLI. Mean C‐reactive protein (CRP), leukocytes and fibrinogen were higher in patients with DLI readmission (P < .02) than in outpatient DLI and patients without DLI, as early as 60 days before readmission. Freedom from DLI readmission was comparable for HMII and HVAD (98% vs. 87%; HR, 4.52; 95% CI, 0.58‐35.02; P = .15) but significantly lower for HM3 (72%; HR, 10.82; 95% CI, 1.26‐92.68; P = .03). DLI (HR, 1.001; 95% CI, 0.999‐1.002; P = .16) or device type had no effect on mortality. DLI readmission remains a serious problem following LVAD implantation, where CRP, leukocytes, and fibrinogen might serve as risk factors already 60 days before. HM3 patients had a higher risk for DLI readmissions compared to HVAD or HMII, possibly because of device‐specific driveline differences.