NEWTON GERALDO BRETAS

Dr. NEWTON GERALDO BRETAS

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2019 in Energies
Verified
Journal Article
Open access
PDF file
PGPedro Julian Garcia-Guarin
Pedro Julian Garcia-Guarin
DRDiego Rodriguez
Diego Rodriguez
DADavid L. Alvarez
David L. Alvarez
SRSergio Rivera
Sergio Rivera
CCCamilo A Cortes
Camilo A Cortes
NBNEWTON GERALDO BRETAS
NEWTON GERALDO BRETAS
Increased use of renewable energies in smart microgrids (SMGs) present new technical challenges to system operation. SMGs must be self-sufficient and operate independently; however, when more elements are integrated into SMGs, as distributed energy resources (DER), traditional explicit mathematical formulations will demand too much data from the network and become intractable. In contrast, tools based on optimization with metaheuristics can provide near optimal solutions in acceptable times. Considering this, this paper presents the variable neighborhood search differential evolutionary particle swarm optimization (VNS-DEEPSO) algorithm to solve multi-objective stochastic control models, as SMGs system operation. The goal is to control DER while maximizing profit. In this work, DER considered the bidirectional communication between energy storage systems (ESS) and electric vehicles (EVs). They can charge/discharge power and buy/sell energy in the electricity markets. Also, they have elements such as traditional generators (e.g., reciprocating engines) and loads, with demand response/control capability. Sources of uncertainty are associated with weather conditions, planned EV trips, load forecasting and the market prices. The VNS-DEEPSO algorithm was the winner of the IEEE Congress on Evolutionary Computation/The Genetic and Evolutionary Computation Conference (IEEE-CEC/GECCO 2019) smart grid competition (with encrypted code) and also won the IEEE World Congress on Computational Intelligence (IEEE-WCCI) 2018 smart grid competition (these competitions were developed by the group GECAD, based at the Polytechnic Institute of Porto, in collaboration with Delft University and Adelaide University). In the IEEE-CEC/GECCO 2019, the relative error improved between 32% and 152% in comparison with other algorithms.

24 January 2018 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
NBNEWTON GERALDO BRETAS
NEWTON GERALDO BRETAS
Arturo BretasArturo Bretas
Arturo Bretas
In this paper is presented an extension of the Gauss approach for the solution of an overdetermined set of algebraic non linear equations. Further, it is shown that the measurement error, in the Gauss approach, is in the measurement direction and that error has a unique decomposition: (i) the first component, which is orthogonal to the Jacobian range space, the residual; and (ii) the other which is on the Jacobian range space. The latter is hidden in the Jacobian space when one minimizes the residual. The extension of the Gauss approach is then in the sense to minimize the norm of the error. In engineering, the measurements may have gross errors, and then detection, identification and correction of those errors are necessary. The Largest Normalized Error Test will be developed for that purpose. Considering the cyber-attack possibility, modeled as a malicious data attack, the error correction step is paramount. Applications on power networks will be used to show the hidden error component when using the Gauss minimization, and also to illustrate all the steps of the presented procedure as well as comparison to the current Gauss approach.

5 July 2017 in IET Cyber-Physical Systems: Theory & Applications
Verified
Journal Article
Open access
PDF file
MAMuharrem Ayar
Muharrem Ayar
RTRodrigo D. Trevizan
Rodrigo D. Trevizan
SOSerhat Obuz
Serhat Obuz
Arturo BretasArturo Bretas
Arturo Bretas
HLHaniph A. Latchman
Haniph A. Latchman
NBNEWTON GERALDO BRETAS
NEWTON GERALDO BRETAS
Transient stability of power systems has become even more critical due to increasing complexity created by large penetration of renewable energy sources and massive deployment of information and communication technology. Fortunately, the two‐way real‐time data exchange capacity of smart grids allows designing advanced digital control schemes to better address the power system stability. In this study, a non‐linear model‐free‐based robust controller in conjunction with a state estimation architecture is designed to enhance transient stability margins. The designed controller addresses uncertainties arising from communication and control input delay, sensor errors, varying plant parameters, and unmodelled dynamics effects. A novel time‐delay compensation technique is presented in the control development to mitigate the effect of delay and the robustness of the proposed controller is proven by conducting a Lyapunov stability analysis with respect to additive disturbance and time delay. Furthermore, the proposed control framework is validated on the IEEE 39 bus test system through MATLAB simulation. The results show that the proposed framework is capable of stabilising the power system after a fault, also showing robustness to noise, latency in communication, delay in control input, and malicious data injection.

18 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
Arturo BretasArturo Bretas
Arturo Bretas
NBNEWTON GERALDO BRETAS
NEWTON GERALDO BRETAS
JMJulio Augusto Druzina Massignan
Julio Augusto Druzina Massignan
JJJoão Bosco Augusto London Junior
João Bosco Augusto London Junior
State-of-the art physics-model based dynamic state estimation generally relies on the assumption that the system’s transition matrix is always correct, the one that relates the states in two different time instants, which might not hold always on real-life applications. Further, while making such assumptions, state-of-the-art dynamic state estimation models become unable to discriminate among different types of anomalies, as measurement gross errors and sudden load changes, and thus automatically leads the state estimator framework to inaccuracy. Towards the solution of this important challenge, in this work, a hybrid adaptive dynamic state estimator framework is presented. Based on the Kalman Filter formulation, measurement innovation analytical-based tests are presented and integrated into the state estimator framework. Gross measurement errors and sudden load changes are automatically detected, identified, and corrected, providing continuous updating of the state estimator. Towards such, the asymmetry index applied to the measurement innovation is introduced, as an anomaly discrimination method, which assesses the physics-model-based dynamic state estimation process in different piece-wise stationary levels. Comparative tests with the state-of-the-art are presented, considering the IEEE 14, IEEE 30, and IEEE 118 test systems. Easy-to-implement-model, without hard-to-design parameters, build-on the classical Kalman Filter solution, highlights potential aspects towards real-life applications.

2 October 2021 in Electricity
Verified
Journal Article
Open access
PDF file
RTRodrigo D. Trevizan
Rodrigo D. Trevizan
CRCody Ruben
Cody Ruben
ARAquiles Rossoni
Aquiles Rossoni
SDSurya C. Dhulipala
Surya C. Dhulipala
Arturo BretasArturo Bretas
Arturo Bretas
NBNEWTON GERALDO BRETAS
NEWTON GERALDO BRETAS
Simultaneous real-time monitoring of measurement and parameter gross errors poses a great challenge to distribution system state estimation due to usually low measurement redundancy. This paper presents a gross error analysis framework, employing μPMUs to decouple the error analysis of measurements and parameters. When a recent measurement scan from SCADA RTUs and smart meters is available, gross error analysis of measurements is performed as a post-processing step of non-linear DSSE (NLSE). In between scans of SCADA and AMI measurements, a linear state estimator (LSE) using μPMU measurements and linearized SCADA and AMI measurements is used to detect parameter data changes caused by the operation of Volt/Var controls. For every execution of the LSE, the variance of the unsynchronized measurements is updated according to the uncertainty introduced by load dynamics, which are modeled as an Ornstein–Uhlenbeck random process. The update of variance of unsynchronized measurements can avoid the wrong detection of errors and can model the trustworthiness of outdated or obsolete data. When new SCADA and AMI measurements arrive, the LSE provides added redundancy to the NLSE through synthetic measurements. The presented framework was tested on a 13-bus test system. Test results highlight that the LSE and NLSE processes successfully work together to analyze bad data for both measurements and parameters.

7 October 2020 in IEEE Transactions on Automatic Control
Verified
Journal Article
Closed access
LALuis Fernando Costa Alberto
Luis Fernando Costa Alberto
DSDaniel S. Siqueira
Daniel S. Siqueira
NBNEWTON GERALDO BRETAS
NEWTON GERALDO BRETAS
HCHsiao-Dong Chiang
Hsiao-Dong Chiang
Nonlinear dynamical systems exhibiting complex structure in their limit sets, such as chaotic and closed orbits, do not admit energy functions. The theory of generalized energy functions, which may assume positive derivative in some bounded sets, appears as an alternative to study the asymptotic behavior of solutions of these systems. In this paper, a generalized energy function and a complete characterization of the stability boundary and stability region are developed for a class of third-order dynamical systems. This class of systems appears in electrical power system models and has a class of quasi-gradient systems and second-order systems as particular cases. These systems may admit complex structure in their limit sets and do not admit an energy function that is general for the class. Numerical examples illustrate how generalized energy functions provide estimates of stability regions.