The importance of lakes and reservoirs leads to the high need for monitoring lake water quality both at local and global scales. The aim of the study was to test suitability of Sentinel-2 Multispectral Imager’s (MSI) data for mapping different lake water quality parameters. In situ data of chlorophyll a (Chl a), water color, colored dissolved organic matter (CDOM) and dissolved organic carbon (DOC) from nine small and two large lakes were compared with band ratio algorithms derived from Sentinel-2 Level-1C and atmospherically corrected (Sen2cor) Level-2A images. The height of the 705 nm peak was used for estimating Chl a. The suitability of the commonly used green to red band ratio was tested for estimating the CDOM, DOC and water color. Concurrent reflectance measurements were not available. Therefore, we were not able to validate the performance of Sen2cor atmospheric correction available in the Sentinel-2 Toolbox. The shape and magnitude of water reflectance were consistent with our field measurements from previous years. However, the atmospheric correction reduced the correlation between the band ratio algorithms and water quality parameters indicating the need in better atmospheric correction. We were able to show that there is good correlation between band ratio algorithms calculated from Sentinel-2 MSI data and lake water parameters like Chl a (R2 = 0.83), CDOM (R2 = 0.72) and DOC (R2 = 0.92) concentrations as well as water color (R2 = 0.52). The in situ dataset was limited in number, but covered a reasonably wide range of optical water properties. These preliminary results allow us to assume that Sentinel-2 will be a valuable tool for lake monitoring and research, especially taking into account that the data will be available routinely for many years, the imagery will be frequent, and free of charge.
Many lakes in boreal and arctic regions have high concentrations of CDOM (coloured dissolved organic matter). Remote sensing of such lakes is complicated due to very low water leaving signals. There are extreme (black) lakes where the water reflectance values are negligible in almost entire visible part of spectrum (400–700 nm) due to the absorption by CDOM. In these lakes, the only water-leaving signal detectable by remote sensing sensors occurs as two peaks—near 710 nm and 810 nm. The first peak has been widely used in remote sensing of eutrophic waters for more than two decades. We show on the example of field radiometry data collected in Estonian and Swedish lakes that the height of the 810 nm peak can also be used in retrieving water constituents from remote sensing data. This is important especially in black lakes where the height of the 710 nm peak is still affected by CDOM. We have shown that the 810 nm peak can be used also in remote sensing of a wide variety of lakes. The 810 nm peak is caused by combined effect of slight decrease in absorption by water molecules and backscattering from particulate material in the water. Phytoplankton was the dominant particulate material in most of the studied lakes. Therefore, the height of the 810 peak was in good correlation with all proxies of phytoplankton biomass—chlorophyll-a (R2 = 0.77), total suspended matter (R2 = 0.70), and suspended particulate organic matter (R2 = 0.68). There was no correlation between the peak height and the suspended particulate inorganic matter. Satellite sensors with sufficient spatial and radiometric resolution for mapping lake water quality (Landsat 8 OLI and Sentinel-2 MSI) were launched recently. In order to test whether these satellites can capture the 810 nm peak we simulated the spectral performance of these two satellites from field radiometry data. Actual satellite imagery from a black lake was also used to study whether these sensors can detect the peak despite their band configuration. Sentinel 2 MSI has a nearly perfectly positioned band at 705 nm to characterize the 700–720 nm peak. We found that the MSI 783 nm band can be used to detect the 810 nm peak despite the location of this band is not in perfect to capture the peak.
The launch of Ocean and Land Colour Instrument (OLCI) on board Sentinel-3A in 2016 is the beginning of a new era in long time, continuous, high frequency water quality monitoring of coastal waters. Therefore, there is a strong need to validate the OLCI products to be sure that the technical capabilities provided will be used in the best possible way in water quality monitoring and research. The Baltic Sea is an optically complex waterbody where many ocean colour products, performing well in other waterbodies, fail. We tested the performance of standard Case-2 Regional/Coast Colour (C2RCC) processing chain in retrieving water reflectance, inherent optical properties (IOPs), and water quality parameters such as chlorophyll a, total suspended matter (TSM) and coloured dissolved organic matter (CDOM) in the Baltic Sea. The reflectance spectra produced by the C2RCC are realistic in both shape and magnitude. However, the IOPs, and consequently the water quality parameters estimated by the C2RCC, did not have correlation with in situ data. On the other hand, some tested empirical remote sensing algorithms performed well in retrieving chlorophyll a, TSM, CDOM and Secchi depth from the reflectance produced by the C2RCC. This suggests that the atmospheric correction part of the processor performs relatively well while IOP retrieval part of the neural network needs extensive training with actual IOP data before it can produce reasonable estimates for the Baltic Sea.
28 June 2016 in International Journal of Remote Sensing
Landsat 8 is the first Earth observation satellite with sufficient radiometric and spatial resolution to allow global mapping of lake CDOM and DOC (coloured dissolved organic matter and dissolved organic carbon, respectively) content. Landsat 8 is a multispectral sensor however, the number of potentially usable band ratios, or more sophisticated indices, is limited. In order to test the suitability of the ratio most commonly used in lake carbon content mapping, the green–red band ratio, we carried out fieldwork in Estonian and Brazilian lakes. Several atmospheric correction methods were also tested in order to use image data where the image-to-image variability due to illumination conditions would be minimal. None of the four atmospheric correction methods tested, produced reflectance spectra that matched well with in situ measured reflectance. Nevertheless, the green–red band ratio calculated from the reflectance data was in correlation with measured CDOM values. In situ data show that there is a strong correlation between CDOM and DOC concentrations in Estonian and Brazilian lakes. Thus, mapping the global CDOM and DOC content from Landsat 8 is plausible but more data from different parts of the world are needed before decisions can be made about the accuracy of such global estimation.
An intercomparison of radiance and irradiance ocean color radiometers (The Second Laboratory Comparison Exercise—LCE-2) was organized within the frame of the European Space Agency funded project Fiducial Reference Measurements for Satellite Ocean Color (FRM4SOC) May 8–13, 2017 at Tartu Observatory, Estonia. LCE-2 consisted of three sub-tasks: 1) SI-traceable radiometric calibration of all the participating radiance and irradiance radiometers at the Tartu Observatory just before the comparisons; 2) Indoor intercomparison using stable radiance and irradiance sources in controlled environment; and 3) Outdoor intercomparison of natural radiation sources over terrestrial water surface. The aim of the experiment was to provide one link in the chain of traceability from field measurements of water reflectance to the uniform SI-traceable calibration, and after calibration to verify whether different instruments measuring the same object provide results consistent within the expected uncertainty limits. This paper describes the activities and results of the first two phases of LCE-2: the SI-traceable radiometric calibration and indoor intercomparison, the results of outdoor experiment are presented in a related paper of the same journal issue. The indoor experiment of the LCE-2 has proven that uniform calibration just before the use of radiometers is highly effective. Distinct radiometers from different manufacturers operated by different scientists can yield quite close radiance and irradiance results (standard deviation s < 1%) under defined conditions. This holds when measuring stable lamp-based targets under stationary laboratory conditions with all the radiometers uniformly calibrated against the same standards just prior to the experiment. In addition, some unification of measurement and data processing must be settled. Uncertainty of radiance and irradiance measurement under these conditions largely consists of the sensor’s calibration uncertainty and of the spread of results obtained by individual sensors measuring the same object.
An intercomparison of radiance and irradiance ocean color radiometers (the second laboratory comparison exercise—LCE-2) was organized within the frame of the European Space Agency funded project Fiducial Reference Measurements for Satellite Ocean Color (FRM4SOC) May 8–13, 2017 at Tartu Observatory, Estonia. LCE-2 consisted of three sub-tasks: (1) SI-traceable radiometric calibration of all the participating radiance and irradiance radiometers at the Tartu Observatory just before the comparisons; (2) indoor, laboratory intercomparison using stable radiance and irradiance sources in a controlled environment; (3) outdoor, field intercomparison of natural radiation sources over a natural water surface. The aim of the experiment was to provide a link in the chain of traceability from field measurements of water reflectance to the uniform SI-traceable calibration, and after calibration to verify whether different instruments measuring the same object provide results consistent within the expected uncertainty limits. This paper describes the third phase of LCE-2: The results of the field experiment. The calibration of radiometers and laboratory comparison experiment are presented in a related paper of the same journal issue. Compared to the laboratory comparison, the field intercomparison has demonstrated substantially larger variability between freshly calibrated sensors, because the targets and environmental conditions during radiometric calibration were different, both spectrally and spatially. Major differences were found for radiance sensors measuring a sunlit water target at viewing zenith angle of 139° because of the different fields of view. Major differences were found for irradiance sensors because of imperfect cosine response of diffusers. Variability between individual radiometers did depend significantly also on the type of the sensor and on the specific measurement target. Uniform SI traceable radiometric calibration ensuring fairly good consistency for indoor, laboratory measurements is insufficient for outdoor, field measurements, mainly due to the different angular variability of illumination. More stringent specifications and individual testing of radiometers for all relevant systematic effects (temperature, nonlinearity, spectral stray light, etc.) are needed to reduce biases between instruments and better quantify measurement uncertainties.