Konstantinos Masouras

Dr. Konstantinos Masouras

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2021 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Closed access
PDF file
PNPanagiotis Ntovas
Panagiotis Ntovas
KMKonstantinos Masouras
Konstantinos Masouras
PLPanagiotis Lagouvardos
Panagiotis Lagouvardos

13 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
MDMaria Dimitriadi
Maria Dimitriadi
Aikaterini PetropoulouAikaterini Petropoulou
Aikaterini Petropoulou
KMKonstantinos Masouras
Konstantinos Masouras
MZMaria Zafiropoulou
Maria Zafiropoulou
Spiros ZinelisSpiros Zinelis
Spiros Zinelis
GEORGE ELIADESGEORGE ELIADES
GEORGE ELIADES
To improve the self-curing capacity and interfacial strength with dentine of dual-cured composite materials, touch-cure activators have been introduced. The aim of the study was to evaluate the effect of these activators on the hardness and conversion of dual-cured resin composite core build-up restoratives. The materials tested were Clearfil DC Core Plus (CF) and Gradia Core (GC) with the corresponding adhesives Clearfil S3 Bond Plus (for CF) and G-Premio Bond/G-Premio DCA activator (for GC). Disk-shaped specimens (n = 6/group) were prepared for the following groups: dual-cured, self-cured and self-cured in contact with the adhesive activators at the bottom surface. After a 3-week storage period (dark/dry/37 °C) the Martens hardness (HM) and degree of conversion (DC%) were determined for the previously mentioned groups and the top surfaces of groups in contact with the adhesives. A statistical analysis was performed by a one-way ANOVA and Holm–Sidak test per material and a Pearson’s correlation analysis (HM vs. DC%) at an α = 0.05. The self-cured specimens resulted in significantly lower HM and DC% values from the dual-cured group, as expected. However, in the presence of the adhesives with touch-cure activators, the conversion of the self-cured groups showed insignificant differences in HM and DC% from the dual-cured in both composite materials. The improvements on the bottom composite surfaces in contact with the adhesives did not extend to the entire specimen length. Nevertheless, improved interfacial curing may improve interfacial durability.

19 June 2024 in Medicina
Verified
Journal Article
Open access
PDF file
EPEftychia Pappa
Eftychia Pappa
GGGrigoria Gkavela
Grigoria Gkavela
ISIoanna Sampri
Ioanna Sampri
KMKonstantinos Masouras
Konstantinos Masouras
Christos RahiotisChristos Rahiotis
Christos Rahiotis
AKAfrodite Kakaboura
Afrodite Kakaboura
Background and objective: The aim of this randomized split-mouth study-controlled clinical trial was to compare the 2-year clinical performance of resin composite restorations placed at non-caries cervical lesions (NCCL) with one-step self-etch, total-etch, and selective enamel etch and self-etch adhesive techniques. Materials and methods: Thirty-two patients received three resin composite restorations each at NCCLs (Tetric EvoCeram/Ivoclar/Vivadent), bonded with a total-etch adhesive agent (ExciTE F/Ivoclar/Vivadent) and a self-etch (AdheSE One F/Ivoclar/Vivadent) without and with selective enamel etching. All restorations were evaluated by two examiners at baseline, 6-, 12-, 18-, and 24-months with FDI clinical criteria (post-operation regarding retention, caries occurrence, marginal adaptation, and marginal staining). A logistic regression analysis, a Cohen’s kappa statistic, a multifactorial analysis, and X2 were performed with generalized estimating equations. Results: After 2 years, the retention rate was 86.8% for total etch, 92.26% for self-etch, and 93.63% for selective enamel etching and self-etch. No caries was detected on the restorations. Concerning marginal adaptation, the clinically perfect restorations were 26.9% for the total-etch technique, 16% for self-etch, and 25.9% for selective enamel etch and self-etch. The logistic regression model revealed that only time reduced the probability of perfect marginal adaptation. Conclusions: All three adhesive strategies provided restorations with no significant differences in the retention rate or marginal adaptation, whereas the total etch yielded better performance for marginal staining. All restorations were assessed as clinically acceptable after 2 years.

24 April 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
EPEftychia Pappa
Eftychia Pappa
GGGrigoria Gkavela
Grigoria Gkavela
ISIoanna Sampri
Ioanna Sampri
KMKonstantinos Masouras
Konstantinos Masouras
Christos RahiotisChristos Rahiotis
Christos Rahiotis
AKAfrodite Kakaboura
Afrodite Kakaboura
The aim of this randomized controlled clinical trial was to compare the 2-year clinical performance of resin composite restorations placed at non-caries cervical lesions (NCCL) with one-step self-etch, total-etch, and selective enamel etch & self-etch adhesive techniques. Thirty-two patients received three resin composite restorations each at NCCLs (Tetric EvoCeram/Ivoclar/Vivadent), bonded with a total-etch adhesive agent (ExciTE F/Ivoclar/Vivadent) and a self-etch (AdheSE One F/Ivoclar/Vivadent) without and with selective enamel etching. All restorations were evaluated by two examiners at baseline, 6-, 12-, 18- and 24-months post-operation regarding retention, caries occurrence, marginal adaptation, and marginal staining. A logistic regression analysis with generalized estimating equations was used. After 2 years, the retention rate was 86,8% for total-etch, 92.26% for self-etch, and 93.63% for selective enamel etching & self-etch. No caries were detected during all the restorations. Concerning marginal adaptation, the clinically perfect restorations were 26.9% for the total-etch technique, 16% for self-etch, and 25,9% for selective enamel etch & self-etch. All three adhesive strategies provided restorations with no significant differences in the retention rate and the marginal adaptation, whereas the total etch yielded better performance for marginal staining. All the restorations were assessed as clinically acceptable after 2 years.

29 December 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
STSocratis Thomaidis
Socratis Thomaidis
KMKonstantinos Masouras
Konstantinos Masouras
EPEfstratios Papazoglou
Efstratios Papazoglou
Objective: This systematic review aimed to analyze if polywave light curing units can polymerize Bulk Fill resin composites better than monowave. Materials and methods: Inclusion criteria were in vitro studies that evaluated the polymerization of Bulk Fill resin composites by monowave and/or polywave light curing units. Selection of studies, data extraction, and risk-of-bias analysis were performed. Data from selected studies were qualitatively analyzed. A systematic search was performed in May 2025 using PubMed/Medline, EBSCO/Medline, Scopus, and ISI Web of Science databases and grey literature in English, and 788 studies were found. Results: A total of 65 studies were included in the qualitative analysis. Seventeen of them were investigating both monowave and polywave light-curing units for the polymerization of Bulk Fill resin composites. The evidence was graded as medium quality due to the medium risk of bias for most studies. Polywave LED LCUs improved the microhardness ratio, or DC, of Bulk Fill resin composite compared to monowave in 3 of the included studies, while 3 studies revealed that monowave LED LCUs demonstrated a favorable microhardness ratio, or DC, compared to polywave, and the rest of the 11 studies presented material-dependent results. Due to the heterogeneity of the studies included, a meta-analysis was not performed. Conclusion: The existing studies, with their limitations, revealed that polywave light curing units do not seem to have an advantage over monowave in the polymerization of Bulk Fill resin composites.

8 May 2023 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
CPChristina Papadopoulou
Christina Papadopoulou
MAMaria Anagnostou
Maria Anagnostou
KMKonstantinos Masouras
Konstantinos Masouras
VMVasileios Margaritis
Vasileios Margaritis
CPCharikleia Paximada
Charikleia Paximada
(1) Background: Single-step polishers are used extensively for resin-composite polishing. The purpose of this study was to evaluate the effect of sterilization on their performance. (2) Methods: Optrapol Next Generation/Ivoclar-Vivadent, Jazz Supreme/SS White, Optishine Brush/Kerr and Jiffy Polishing Brush/Ultradent were used for polishing a nanohybrid resin composite (IPS Empress Direct/Ivoclar-Vivadent). Polishers (n = 40) were microscopically inspected before use. After polishing, surface roughness (Sa, Sz, Sdr, Sci) and gloss were determined. Polishers were subsequently sterilized and microscopically re-examined. The process was repeated four times on new samples (n = 200). Data were analyzed using the Friedman test and Wilcoxon post hoc test, at α = 0.05. (3) Results: Optrapol’s performance improved after the first sterilization for Sa and gloss, whereas it declined after the fourth sterilization for Sa. Jazz’s, improved after the second sterilization for Sa and gloss and after the third sterilization for Sdr. An improvement trend was observed for Optishine after the first sterilization, but not statistically significant. Sa, Sz, and gloss declined after the fourth sterilization. Jiffy’s performance was inconsistent, with a trend of performance loss after the fourth sterilization. (4) Conclusions: Performance of all polishing systems improved after the initial sterilization, but deteriorated after the fourth sterilization cycle. However, their performance can be considered clinically acceptable for a longer period of use.