SILVIA SAULEDA

Dr. SILVIA SAULEDA

Banc de Sang i Teixits, Barcelona, Catalonia, Spain
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2014 in Transfusion
Verified
Journal Article
Closed access
PDF file
SSSILVIA SAULEDA
SILVIA SAULEDA
EOEdgar Ong
Edgar Ong
MBMarta Bes
Marta Bes
AJAlanna Janssen
Alanna Janssen
RCRobin Cory
Robin Cory
JLJeffrey M. Linnen
Jeffrey M. Linnen

13 October 2021 in Viruses
Verified
Journal Article
Open access
PDF file
MKMary Kuhns
Mary Kuhns
VHVera Holzmayer
Vera Holzmayer
MAMark Anderson
Mark Anderson
AManne l mcnamara
anne l mcnamara
SSSILVIA SAULEDA
SILVIA SAULEDA
GCGavin A. Cloherty
Gavin A. Cloherty
Background: Gaps remain in the detection of nucleic acid test (NAT) yield and occult hepatitis B virus (HBV) infection (OBI) by current HBV surface antigen (HBsAg) assays. The lack of detection may be due to HBsAg levels below current assay detection limits, mutations affecting HBsAg assays or HBsAg levels, or the masking of HBsAg by antibody to HBsAg (anti-HBs). In this study, we evaluate the incremental detection of NAT yield and OBI from five diverse geographic areas by an improved sensitivity HBsAg assay and characterize the samples relative to the viral load, anti-HBs status, and PreS1–S2–S mutations. Included is a comparison population with HBV DNA levels comparable to OBI, but with readily detectable HBsAg (High Surface–Low DNA, HSLD). Methods: A total of 347 samples collected from the USA, South Africa, Spain, Cameroon, Vietnam, and Cote D’Ivoire representing NAT yield (HBsAg(−), antibody to HBV core antigen (anti-HBc)(−), HBV DNA(+), N = 131), OBI (HBsAg(−), anti-HBc(+), HBV DNA(+), N = 188), and HSLD (HBsAg(+), anti-HBc(+), HBV DNA(+), N = 28) were tested with ARCHITECT HBsAg NEXT (HBsAgNx) (sensitivity 0.005 IU/mL). The sequencing of the PreS1–S2–S genes from a subset of 177 samples was performed to determine the genotype and assess amino acid variability, particularly in anti-HBs(+) samples. Results: HBsAgNx detected 44/131 (33.6%) NAT yield and 42/188 (22.3%) OBI samples. Mean HBV DNA levels for NAT yield and OBI samples were lower in HBsAgNx(−) (50.3 and 25.9 IU/mL) than in HBsAgNx(+) samples (384.1 and 139.5 IU/mL). Anti-HBs ≥ 10 mIU/mL was present in 28.6% HBsAgNx(+) and 45.2% HBsAgNx(−) OBI, and in 3.6% HSLD samples. The genotypes were A1, A2, B, C, D, E, F, and H. There was no significant difference between HBsAgNx(−) and HBsAgNx(+) in the proportion of samples harboring substitutions or in the mean number of substitutions per sample in PreS1, PreS2, or S for the NAT yield or OBI (p range: 0.1231 to >0.9999). A total of 21/27 (77.8%) of HBsAgNx(+) OBI carried S escape mutations, insertions, or stop codons. HSLD had more PreS1 and fewer S substitutions compared to both HBsAgNx(−) and HBsAgNx(+) OBI. Mutations/deletions associated with impaired HBsAg secretion were observed in the OBI group. Conclusions: HBsAgNx provides the improved detection of NAT yield and OBI samples. Samples that remain undetected by HBsAgNx have exceptionally low HBsAg levels below the assay detection limit, likely due to low viremia or the suppression of HBsAg expression by host and viral factors.

Verified
Journal Article
Open access
PDF file
MLMeritxell Llorens-Revull
Meritxell Llorens-Revull
BMBrenda Martínez-González
Brenda Martínez-González
JQJosep Quer
Josep Quer
JEJuan Ignacio Esteban
Juan Ignacio Esteban
GNGonzalo Núñez-Moreno
Gonzalo Núñez-Moreno
Maria I. CostafredaMaria I. Costafreda
Maria I. Costafreda
MicroRNAs (miRNAs) encapsulated in extracellular vesicles (EVs) are potential diagnostic and prognostic biomarkers. However, discrepancies in miRNA patterns and their validation are still frequent due to differences in sample origin, EV isolation, and miRNA sequencing methods. The aim of the present study is to find a reliable EV isolation method for miRNA sequencing, adequate for clinical application. To this aim, two comparative studies were performed in parallel with the same human plasma sample: (i) isolation and characterization of EVs obtained using three procedures: size exclusion chromatography (SEC), iodixanol gradient (GRAD), and its combination (SEC+GRAD) and (ii) evaluation of the yield of miRNA sequences obtained using NextSeq 500 (Illumina) and three miRNA library preparation protocols: NEBNext, NEXTFlex, and SMARTer smRNA-seq. The conclusion of comparison (i) is that recovery of the largest amount of EVs and reproducibility were attained with SEC, but GRAD and SEC+GRAD yielded purer EV preparations. The conclusion of (ii) is that the NEBNext library showed the highest reproducibility in the number of miRNAs recovered and the highest diversity of miRNAs. These results render the combination of GRAD EV isolation and NEBNext library preparation for miRNA retrieval as adequate for clinical applications using plasma samples.

4 October 2018 in Transfusion
Verified
Journal Article
Closed access
PDF file
MRMar Riveiro-Barciela
Mar Riveiro-Barciela
MBMarta Bes
Marta Bes
JQJosep Quer
Josep Quer
DFDavid Valcárcel Ferreiras
David Valcárcel Ferreiras
SPSofia Piriz
Sofia Piriz
SSSILVIA SAULEDA
SILVIA SAULEDA

5 July 2017 in Transfusion
Verified
Journal Article
Closed access
PDF file
MBMarta Bes
Marta Bes
MPMaria Piron
Maria Piron
NCNatàlia Casamitjana
Natàlia Casamitjana
Josep GregoriJosep Gregori
Josep Gregori
JEJuan Ignacio Esteban
Juan Ignacio Esteban
SSSILVIA SAULEDA
SILVIA SAULEDA

1 April 2023 in Hepatology Communications
Verified
Journal Article
Open access
MRMary A Rodgers
Mary A Rodgers
PSPir Shah
Pir Shah
MAMark Anderson
Mark Anderson
AVAna S. Vallari
Ana S. Vallari
JGJeffrey Gersch
Jeffrey Gersch
DLDaryl T-Y Lau
Daryl T-Y Lau
Background: The loss of HBV HBsAg or functional cure is a desirable goal of hepatitis B management. The relative abundances of HBsAg isoforms may offer additional diagnostic and predicting values. To evaluate the clinical utility of HBsAg isoforms, we developed novel prototype assays on the ARCHITECT automated serology platform that specifically detects total-HBsAg (T-HBsAg), large (L-HBsAg), and middle (M-HBsAg) products of the S gene to determine the isoform composition of human specimens from acute and chronic HBV infection and during long-term nucleos(t)ide analog therapy. Results: In the early phase of acute HBV infection, L-HBsAg and M-HBsAg emerged within days and were in parallel to T-HBsAg during the entire course of infection. M-HBsAg levels were consistently higher than L-HBsAg levels. Patients with HBeAg(+) chronic hepatitis B had higher T-HBsAg, M-HBsAg, and L-HBsAg levels compared with HBeAg(−) patients. Correlations of M-HBsAg and L-HBsAg to T-HBsAg were similar in both. In contrast, there was no strong correlation between L-HBsAg or M-HBsAg with HBV DNA levels. During long-term nucleos(t)ide analog treatment, changes in HBsAg isoform abundance were proportional to T-HBsAg regardless of treatment responses for both HBeAg(+) and HBeAg(−) chronic hepatitis B. A larger sample size may be necessary to detect a significant difference. Conclusion: HBsAg isoform compositions parallel T-HBsAg levels in both acute and chronic hepatitis B infection. L-HBsAg and M-HBsAg individual biomarkers do not appear to provide an additional diagnostic benefit for staging chronic disease or monitoring response to treatment with current therapies.