Piotr Kowalski

Dr. Piotr Kowalski

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
PKPiotr Kowalski
Piotr Kowalski
Pawel SzalanskiPawel Szalanski
Pawel Szalanski
Wojciech CepińskiWojciech Cepiński
Wojciech Cepiński
The paper presents an analysis of the application of an air-to-water electric compressor heat pump (AWHP) for the recovery of waste heat from the exhaust air in a typical multifamily residential building and the use of this heat for space heating, as well as the impact of this solution on the building energy performance (the PPR index). Simulations were performed in TRNSYS for five locations in Poland (Koszalin, Wrocław, Lublin, Białystok, Suwałki), for various heating system parameters (80/60 °C, 75/65 °C, 70/50 °C, 55/45 °C, 35/28 °C), for various temperature limitations of heat pump operation. It was shown that the analyzed system has great potential from an energy and environmental point of view. It can provide significant benefits in terms of the energy performance of the building, depending on the system parameters. The results show that the most energy-efficient system is the one with the lowest heating system temperatures. Moreover, implementing a temperature limitation on the heat pump operation improves its efficiency, but the higher the design parameters of the heating installation and the lower the limitation, the lower the heat pump contribution, and the higher the SCOP and the PPR. The energy effect is also influenced by location, but its scale depends on the parameters of the heating system and the temperature limitation of the heat pump’s operation. It is more significant for lower heating system parameters. This system enables the possibility of further reducing the demand for nonrenewable primary energy by powering the heat pump with photovoltaic cells.

24 May 2017
Verified
Conference Paper
Open access
PDF file
PKPiotr Kowalski
Piotr Kowalski
Pawel SzalanskiPawel Szalanski
Pawel Szalanski
E3S Web of Conferences, open access proceedings in environment, energy and earth sciences

24 September 2019 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
PKPiotr Kowalski
Piotr Kowalski
Pawel SzalanskiPawel Szalanski
Pawel Szalanski
The article discusses the problem of determining for air heat pumps the seasonal efficiency of energy production necessary to determine the energy performance of a building. On the example of selected Polish cities (Suwalki, Bialystok, Warsaw, Wroclaw, Zielona Gora, Resko, Szczecinek, Koszalin) the influence of climatic conditions on the SCOP of an exemplary air-to-air heat pump and on the result of building energy performance calculations was analysed. SCOPs for each location were determined according to the method of EN 14825. The difference between SCOP for average (A) and colder (C) climates according to EN 14825 was 35.6%. It has been shown that the climate of Polish cities may be similar to both the average climate (A) and the colder climate (C), or they significantly differ from both climates. The most significant difference in SCOP between the analysed cities was obtained for Suwalki and Szczecinek. It was 31.9% and 31.4% for the assumed heating season length as for climate (A) and (C) respectively. For the exemplary building in Suwalki, taking SCOP for the average climate (A) and not based on climatic data of Suwalki gives an error of 39.3% in the calculation of primary energy for heating. For the same locations, the differences in SCOP and EP resulting from the assumption of the heating season length as for the average climate (A) or as for the colder climate (C) were respectively from 2.4% to 3.3% and from -3.4% to -2.2%. In diversified Polish climate, assuming the same SCOP values of air heat pumps regardless of location does not allow for their full comparison with devices whose efficiency does not depend on climatic conditions. The authors suggest that when calculating the energy performance of the building, the SCOP should be always determined on the basis of the local climate and the length of the heating season.

3 July 2018 in E3S Web of Conferences
Verified
Conference Paper
Open access
PKPiotr Kowalski
Piotr Kowalski
Pawel SzalanskiPawel Szalanski
Pawel Szalanski
The article presents results of air permeability measurements carried out for envelopes of two entire typical single-family residential buildings and separately for envelopes of garages and residential zones of these buildings. The effect of taking into account separate air permeability measurements of building zones on the calculation results of infiltration heat losses and on the energy need for heating is analysed. The calculation results obtained in this way are then compared to calculation results obtained in the case of air permeability measurements of the entire building envelope.

7 August 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
Pawel SzalanskiPawel Szalanski
Pawel Szalanski
PKPiotr Kowalski
Piotr Kowalski
Wojciech CepińskiWojciech Cepiński
Wojciech Cepiński
PKPiotr Kęskiewicz
Piotr Kęskiewicz
This article analyzes the possibility of reducing the energy consumption from building heating as a result of lowering the indoor air temperature, which is recommended as a response to the energy crisis. Various values of the set-point temperature (16–22 °C), as well as different scenarios for their changes, were assumed for analysis. Changes in clothing that were determined to maintain the same level of thermal comfort after a temperature change were determined. The associated reduction in CO2 emissions emitted into the atmosphere was determined. The effect of reducing CO2 emissions was studied depending on the type of heating source. Simulation calculations were carried out for an exemplary multifamily building. The effect of different building insulations required in Poland over the years 1964–2022 was considered. Analyses were performed for the climatic conditions of cities located in different climatic zones of Poland: Koszalin, Wroclaw, Warsaw, Bialystok, Suwalki. Depending on the scenario, the insulation standard of the building, and the variant of location, the energy reduction achieved ranges from 6.6%/K to 13.2%/K. Taking into account the type of heating source, the reduction in CO2 emissions is from 0.7 to 7.5 kgCO2/(K·m2). The reduction in temperature by 1 or 2 K can be compensated for by wearing an additional sleeveless vest (0.12 clo) or sweater (0.28 clo).

6 December 2025 in Energies
Verified
Journal Article
Open access
PDF file
Pawel SzalanskiPawel Szalanski
Pawel Szalanski
PKPiotr Kowalski
Piotr Kowalski
This work deals with the performance gap between prognostic models of the energy needed for heating and actual energy consumption based on measurements. An in-depth case study is presented for a real single-family building, taking into account physical calculation models (monthly and simple hourly method according to the Polish methodology based on standard EN ISO 13790) and relevant input data. The hypothesis is confirmed in that it is possible to achieve high convergence between actual energy consumption and the calculated energy need when taking into account the high-quality input data obtained using relatively simple measurement methods. The results indicate the impact of key input data on the computational energy needed for heating. For the case study considered, the greatest influence is caused by the introduction of actual internal heat gains. Entering only some of the actual data may yield a result that is farther from the actual value than a result based only on standard data. This article provides knowledge that leads to the development of a “new consumption method” using physical models in combination with available high-quality input data, which helps change regulations and increase the significance of energy performance certificates in Poland.