Pawel Szalanski

Dr. Pawel Szalanski

Faculty of Environmental Engineering, Wrocław University of Science and Technology, Wrocław, Dolnośląskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
Edyta DudkiewiczEdyta Dudkiewicz
Edyta Dudkiewicz
Natalia Fidorów-KaprawyNatalia Fidorów-Kaprawy
Natalia Fidorów-Kaprawy
Pawel SzalanskiPawel Szalanski
Pawel Szalanski
This paper demonstrates the need and potential for using waste heat recovery (WHR) systems from infrared gas radiant heaters, which are typical heat sources in large halls, due to the increasing energy-saving requirements for buildings in the EU and the powerful and wide-spread development of the e-commerce market. The types of gas radiant heaters are discussed and the classification of WHR systems from these devices is performed. The article also presents for the first time our innovative solution, not yet available on the market, for the recovery of heat from the exhaust gases of ceramic infrared heaters. The energy analysis for an industrial hall shows that this solution allows for environmental benefits at different levels, depending on the gas infrared heater efficiency, by reducing the amount of fuel and emissions for domestic hot water (DHW) preparation (36.8%, 15.4% and 5.4%, respectively, in the case of low-, standard- and high-efficiency infrared heaters). These reductions, considering both DHW preparation and hall heating, are 16.1%, 7.6% and 3.0%, respectively. The key conclusion is that the innovative solution can spectacularly improve the environmental effect and achieve the highest level of fuel savings in existing buildings that are heated with radiant heaters with the lowest radiant efficiency.

29 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
PKPiotr Kowalski
Piotr Kowalski
Pawel SzalanskiPawel Szalanski
Pawel Szalanski
Wojciech CepińskiWojciech Cepiński
Wojciech Cepiński
The paper presents an analysis of the application of an air-to-water electric compressor heat pump (AWHP) for the recovery of waste heat from the exhaust air in a typical multifamily residential building and the use of this heat for space heating, as well as the impact of this solution on the building energy performance (the PPR index). Simulations were performed in TRNSYS for five locations in Poland (Koszalin, Wrocław, Lublin, Białystok, Suwałki), for various heating system parameters (80/60 °C, 75/65 °C, 70/50 °C, 55/45 °C, 35/28 °C), for various temperature limitations of heat pump operation. It was shown that the analyzed system has great potential from an energy and environmental point of view. It can provide significant benefits in terms of the energy performance of the building, depending on the system parameters. The results show that the most energy-efficient system is the one with the lowest heating system temperatures. Moreover, implementing a temperature limitation on the heat pump operation improves its efficiency, but the higher the design parameters of the heating installation and the lower the limitation, the lower the heat pump contribution, and the higher the SCOP and the PPR. The energy effect is also influenced by location, but its scale depends on the parameters of the heating system and the temperature limitation of the heat pump’s operation. It is more significant for lower heating system parameters. This system enables the possibility of further reducing the demand for nonrenewable primary energy by powering the heat pump with photovoltaic cells.

24 September 2019 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
Edyta DudkiewiczEdyta Dudkiewicz
Edyta Dudkiewicz
Pawel SzalanskiPawel Szalanski
Pawel Szalanski
Heating of large-cubage buildings accounts for significant share of energy consumption. The radiant heating system using gas heaters is a common solution for large-cubage halls and is considered to be energy efficient. There is a possibility of additional heat energy recovery from the flue gases of gas radiant heaters because new solutions were introduced to the market. Furthermore heat recovery consists the most promising solution and develop during the recent years rapidly. On the other hand, few works have been dedicated to heat recovery from exhaust gas but none of them consider exhaust gas from radiant heaters. Exhaust gas temperature depends on the type and efficiency of the gas heater. The selection of both the type of radiant heaters and the heat recovery system requires many factors to be taken into account. This study consider possibilities for application of different heat exchangers in exhaust gases system of gas radiant heaters. The authors propose to classify exhaust gas heat recovery systems in dependence on intermediary medium: water/air, gas heaters type: ceramic/tube and number (single/group) and their mounting location.

24 May 2017
Verified
Conference Paper
Open access
PDF file
PKPiotr Kowalski
Piotr Kowalski
Pawel SzalanskiPawel Szalanski
Pawel Szalanski
E3S Web of Conferences, open access proceedings in environment, energy and earth sciences

24 September 2019 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
PKPiotr Kowalski
Piotr Kowalski
Pawel SzalanskiPawel Szalanski
Pawel Szalanski
The article discusses the problem of determining for air heat pumps the seasonal efficiency of energy production necessary to determine the energy performance of a building. On the example of selected Polish cities (Suwalki, Bialystok, Warsaw, Wroclaw, Zielona Gora, Resko, Szczecinek, Koszalin) the influence of climatic conditions on the SCOP of an exemplary air-to-air heat pump and on the result of building energy performance calculations was analysed. SCOPs for each location were determined according to the method of EN 14825. The difference between SCOP for average (A) and colder (C) climates according to EN 14825 was 35.6%. It has been shown that the climate of Polish cities may be similar to both the average climate (A) and the colder climate (C), or they significantly differ from both climates. The most significant difference in SCOP between the analysed cities was obtained for Suwalki and Szczecinek. It was 31.9% and 31.4% for the assumed heating season length as for climate (A) and (C) respectively. For the exemplary building in Suwalki, taking SCOP for the average climate (A) and not based on climatic data of Suwalki gives an error of 39.3% in the calculation of primary energy for heating. For the same locations, the differences in SCOP and EP resulting from the assumption of the heating season length as for the average climate (A) or as for the colder climate (C) were respectively from 2.4% to 3.3% and from -3.4% to -2.2%. In diversified Polish climate, assuming the same SCOP values of air heat pumps regardless of location does not allow for their full comparison with devices whose efficiency does not depend on climatic conditions. The authors suggest that when calculating the energy performance of the building, the SCOP should be always determined on the basis of the local climate and the length of the heating season.

10 June 2019
Verified
Conference Paper
Open access
PDF file
Wojciech CepińskiWojciech Cepiński
Wojciech Cepiński
Pawel SzalanskiPawel Szalanski
Pawel Szalanski
The article presents the possibility of using exhaust air from ventilation system to increase the efficiency (SCOP, COP, SEER and EER) of commonly used air conditioners with the function of a heat pump. These types of devices are very popular both in residential and in public buildings. The topic discussed in the article is very important, because the widespread increase of the energy efficiency of these devices significantly influences national electricity consumption. The possibility of increasing their efficiency by directing the exhaust air from the ventilation system to the heat exchanger of the air conditioner outdoor unit has been analysed. It has been shown that the use of the simple design solution described in the article allows for a significant increase of the efficiency of these devices (seasonal efficiency even up to 35% at 100% share of exhaust air), reducing the energy consumption and increasing their capacity and operation range. By increasing the share of exhaust air it is possible to ensure year-round operation of the device and even 100% coverage of heat demand.