Masahiro Todoh

Masahiro Todoh

orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in Osteoarthritis and Cartilage
Verified
Journal Article
Closed access
SES. Elmorsy
S. Elmorsy
TFT. Funakoshi
T. Funakoshi
FSF. Sasazawa
F. Sasazawa
MTMasahiro Todoh
Masahiro Todoh
STShigeru Tadano
Shigeru Tadano
NINorimasa Iwasaki
Norimasa Iwasaki

Verified
Journal Article
Open access
PDF file
Dawit Bogale AlemayehuDawit Bogale Alemayehu
Dawit Bogale Alemayehu
MTMasahiro Todoh
Masahiro Todoh
Bio-inspired gyroid triply periodic minimum surface (TPMS) lattice structures have been the focus of research in automotive engineering because they can absorb a lot of energy and have wider plateau ranges. The main challenge is determining the optimal energy absorption capacity and accurately capturing plastic plateau areas using finite element analysis (FEA). Using nTop’s Boolean subtraction method, this study combined walled TPMS gyroid structures with a normal TPMS gyroid lattice. This made a composite TPMS gyroid lattice (CTG) with relative densities ranging from 14% to 54%. Using ideaMaker 4.2.3 (3DRaise Pro 2) software and the fused deposition modeling (FDM) Raise3D Pro 2 3D printer to print polylactic acid (PLA) bioplastics in 1.75 mm filament made it possible to slice computer-aided design (CAD) models and fabricate 36 lattice samples precisely using a layer-by-layer technique. Shimadzu 100 kN testing equipment was utilized for the mechanical compression experiments. The finite element approach validates the results of mechanical compression testing. Further, a composite CTG was examined using a field emission scanning electron microscope (FE-SEM) before and after compression testing. The composite TPMS gyroid lattice showed potential as shock absorbers for vehicles with relative densities of 33%, 38%, and 54%. The Gibson–Ashby model showed that the composite TPMS gyroid lattice deformed mainly by bending, and the size effect was seen when the relative densities were less than 15%. The lattice’s relative density had a significant impact on its ability to absorb energy. The research also explored the use of these innovative foam-like composite TPMS gyroid lattices in high-speed crash box scenarios to potentially enhance vehicle safety and performance. The structures have tremendous potential to improve vehicle safety by acting as advanced shock absorbers, which are particularly effective at higher relative densities.

11 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
YGYutong Gu
Yutong Gu
HOHiromasa Oku
Hiromasa Oku
MTMasahiro Todoh
Masahiro Todoh
Sign language is designed as a natural communication method to convey messages among the deaf community. In the study of sign language recognition through wearable sensors, the data sources are limited, and the data acquisition process is complex. This research aims to collect an American sign language dataset with a wearable inertial motion capture system and realize the recognition and end-to-end translation of sign language sentences with deep learning models. In this work, a dataset consisting of 300 commonly used sentences is gathered from 3 volunteers. In the design of the recognition network, the model mainly consists of three layers: convolutional neural network, bi-directional long short-term memory, and connectionist temporal classification. The model achieves accuracy rates of 99.07% in word-level evaluation and 97.34% in sentence-level evaluation. In the design of the translation network, the encoder-decoder structured model is mainly based on long short-term memory with global attention. The word error rate of end-to-end translation is 16.63%. The proposed method has the potential to recognize more sign language sentences with reliable inertial data from the device.

Verified
Journal Article
Open access
PDF file
Dawit Bogale AlemayehuDawit Bogale Alemayehu
Dawit Bogale Alemayehu
MTMasahiro Todoh
Masahiro Todoh
Song-Jeng HuangSong-Jeng Huang
Song-Jeng Huang
Background: Dental implantology has evolved significantly since the introduction of additive manufacturing, which allows for the reproduction of natural bone’s porous architecture to improve bone tissue compatibility and address stress distribution issues important to long-term implant success. Conventional solid dental implants frequently cause stress shielding, which compromises osseointegration and reduces durability. Aim: The current research proposes to examine the biomechanical efficacy of fully and hybrid gyroid triply periodic minimum surface (TPMS) latticed implants across different cell sizes to optimize stress distribution and improve implant durability. Methods: This study evaluates six fully and hybrid gyroid (TPMS) latticed implants, including fully latticed designs with three cell sizes—FLI_111 (1 mm × 1 mm × 1 mm), FLI_222 (2 mm × 2 mm × 2 mm), and FLI_333 (3 mm × 3 mm × 3 mm)—and hybrid gyroid TPMS latticed implants with solid necks in corresponding sizes—HI_111, HI_222, and HI_333. To enhance initial stability, a square-threaded design was added into the bottom part of both fully and hybrid lattice implants. The designs also incorporate anti-rotational connections to enhance fixation, and they undergo a clinical viability comparison with contemporary implants. To improve lattice designs, finite element analysis (FEA) was utilized through nTopology (nTOP 4.17.3) to balance stiffness and flexibility. To examine mechanical performance under realistic conditions, a dynamic mastication loading simulation was conducted for 1.5 s across three cycles. Results: The findings reveal that hybrid implants, particularly HI_222, exhibited improved mechanical characteristics by reducing micromotions at the bone–implant interface, improving osteointegration, and attaining better stress distribution. Conclusions: By addressing stress shielding and boosting implant performance, this work paves the way for personalized implant designs, developing dental technology, and improving clinical results.

3 November 2015 in Tissue Engineering Part C: Methods
Verified
Journal Article
Closed access
RBRikiya Baba
Rikiya Baba
TOTomohiro Onodera
Tomohiro Onodera
DMDaisuke Momma
Daisuke Momma
MMMasatake Matsuoka
Masatake Matsuoka
KHKazutoshi Hontani
Kazutoshi Hontani
NINorimasa Iwasaki
Norimasa Iwasaki
Cartilage injuries are a common health problem resulting in the loss of daily activities. Bone marrow stimulation technique, one of the surgical techniques for the cartilage injuries, is characterized by technical simplicity and less invasiveness. However, it has been shown to result in fibrous or fibrocartilaginous repair with inferior long-term results. This study focused on using ultrapurified alginate gel (UPAL gel) as an adjuvant scaffold in combination with a bone marrow stimulation technique. The objective of this study was to assess the efficacy of a bone marrow stimulation technique augmented by UPAL gel in a rabbit osteochondral defect model. To achieve this goal, three experimental groups were prepared as follows: defects without intervention, defects treated with a bone marrow stimulation technique, and defects treated with a bone marrow stimulation technique augmented by UPAL gel. The macroscopic and histological findings of the defects augmented by UPAL gel improved significantly more than those of the others at 16 weeks postoperatively. The combination technique elicited hyaline-like cartilage repair, unlike bone marrow stimulation technique alone. This combination procedure has the potential of improving clinical outcomes after use of a bone marrow stimulation technique for articular cartilage injuries.

21 August 2020 in Metals
Verified
Journal Article
Open access
PDF file
AZAqmar Zakaria
Aqmar Zakaria
HSHamdi Shukor
Hamdi Shukor
MTMasahiro Todoh
Masahiro Todoh
KJKamaruzaman Jusoff
Kamaruzaman Jusoff
One way to improve the biofunctionality of titanium alloys is by implementing plasma electrolytic oxidation (PEO) to incorporate bioactive elements such as fluoridated hydroxyapatite, into surface coatings of orthopaedic and dental implants. Hydroxyapatite (HAp) is known as a bioactive coating while fluorapatite (FAp) has an antibacterial effect that would enhance the bio-functionality and reduce the failure rate of orthopaedic and dental implants. The purpose of this study was to develop fluoridated hydroxyapatite as a bio-functional coating on Ti6Al4V with electrolyte containing trisodium orthophosphate, potassium hydroxide, and calcium fluoride. The coating surface and cross-section morphologies were evaluated, and the species in the electrolyte solution were found, and irregular micropores shapes were observed by field emission scanning electron microscopy (FESEM) and energy dispersive spectrometer (EDS). The phase composition of the coating surface containing TiO2 (anatase and rutile), tricalcium orthophosphate, HAp, and FAp was characterized by X-ray diffractometer (XRD). The adhesive strength of the coating was analysed by a micro-scratch test. Simulated body fluid (SBF) immersion test was performed to investigate the bioactivity of the coating. In this study, we demonstrated that the PEO technique has a good potential to develop bio-functional surface modifications that can affect the chemical composition and roughness of the coating surface. The FAp coating may provide insights for subsequent bioactive coatings while improving the antibacterial properties for orthopaedic and dental implants. Future work shall investigate the optimal amount of fluoride in the coating layer that obtains excellent results without causing adverse effects on adjacent tissue.