Pantelis Karaiskos

Prof. Dr. Pantelis Karaiskos


Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
GPGeorgia Prentou
Georgia Prentou
EPEleftherios P Pappas
Eleftherios P Pappas
ALAndreas Logothetis
Andreas Logothetis
EKEfi Koutsouveli
Efi Koutsouveli
EPEvaggelos Pantelis
Evaggelos Pantelis
PKPantelis Karaiskos
Pantelis Karaiskos
Purpose: In the absence of a 6D couch and/or assuming considerable intrafractional patient motion, rotational errors could affect target coverage and OAR‐sparing especially in multiple metastases VMAT‐SRS cranial cases, which often involve the concurrent irradiation of off‐axis targets. This work aims to study the dosimetric impact of rotational errors in such applications, under a comparative perspective between the single‐ and two‐isocenter treatment techniques.Methods: Ten patients (36 metastases) were included in this study. Challenging cases were only considered, with several targets lying in close proximity to OARs. Two multiarc VMAT plans per patient were prepared, involving one and two isocenters, serving as the reference plans. Different degrees of angular offsets at various orientations were introduced, simulating rotational errors. Resulting dose distributions were evaluated and compared using commonly employed dose‐volume and plan quality indices.Results: For single‐isocenter plans and 1⁰ rotations, plan quality indices, such as coverage, conformity index and D95%, deteriorated significantly (>5%) for distant targets from the isocenter (at> 4–6 cm). Contrarily, for two‐isocenter plans, target distances to nearest isocenter were always shorter (≤4 cm), and, consequently, 1⁰ errors were well‐tolerated. In the most extreme case considered (2⁰ around all axes) conformity index deteriorated by on‐average 7.2%/cm of distance to isocenter, if one isocenter is used, and 2.6%/cm, for plans involving two isocenters. The effect is, however, strongly associated with target volume. Regarding OARs, for single‐isocenter plans, significant increase (up to 63%) in Dmax and D0.02cc values was observed for any angle of rotation. Plans that could be considered clinically unacceptable were obtained even for the smallest angle considered, although rarer for the two‐isocenter planning approach.Conclusion: Limiting the lesion‐to‐isocenter distance to ≤4 cm by introducing additional isocenter(s) appears to partly mitigate severe target underdosage, especially for smaller target sizes. If OAR‐sparing is also a concern, more stringent rotational error tolerances apply.

1 December 2014 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
PKPantelis Karaiskos
Pantelis Karaiskos
AMArgyris Moutsatsos
Argyris Moutsatsos
EPEleftherios P. Pappas
Eleftherios P. Pappas
EGEvangelos Georgiou
Evangelos Georgiou
ARArkadios Roussakis
Arkadios Roussakis
ISIOANNIS SEIMENIS
IOANNIS SEIMENIS

19 January 2011 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
CCChristos Chatzigiannis
Christos Chatzigiannis
GLGeorgia Lymperopoulou
Georgia Lymperopoulou
PSPanagiotis Sandilos
Panagiotis Sandilos
CDConstantinos Dardoufas
Constantinos Dardoufas
EYEmmanouil Yakoumakis
Emmanouil Yakoumakis
PKPantelis Karaiskos
Pantelis Karaiskos
External beam radiation therapy (RT) is often offered to breast cancer patients after surgical mastectomy followed by breast reconstruction with silicone implants. In some cases, the RT is administered while the patient is still implanted with a temporary tissue expander including a high‐density metallic port, which is expected to affect the planned dose distribution.This work uses Monte Carlo (MC) simulation in order to evaluate the aforementioned effect when the McGhan Style 133 Tissue Expander with the Magna‐Site injection port is used. Simulations have been performed on a patient model built using the actual CT images of the patient for two irradiation schemes, involving two tangential photon beams of 6 MV and 18 MV respectively. MC results show that the presence of the Magna‐Site within the two irradiation fields leads to an overall reduction of absorbed dose for points lying in the shadow of the metallic port (relative to each of the opposing beams). The relative reduction compared to dose results without the expander in place ranges from 7% to 13% for the 6 MV beam and is around 6% for the 18 MV photon beam. However, in the close vicinity of the metallic port, increased absorbed doses are observed, due to the increase of secondary electrons emerging from the metallic part of the insert.PACS numbers: 87.53.Bn, 87.55.K‐, 29.20.‐c, 87.56.bd, 75.50.‐y

20 September 2016 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
EPEleftherios P. Pappas
Eleftherios P. Pappas
ISI Seimenis
I Seimenis
AMArgyris Moutsatsos
Argyris Moutsatsos
EGE Georgiou
E Georgiou
PNP Nomikos
P Nomikos
PKPantelis Karaiskos
Pantelis Karaiskos
This work provides characterization of system-related geometric distortions present in MRIs used in Gamma Knife (GK) stereotactic radiosurgery (SRS) treatment planning. A custom-made phantom, compatible with the Leksell stereotactic frame model G and encompassing 947 control points (CPs), was utilized. MR images were obtained with and without the frame, thus allowing discrimination of frame-induced distortions. In the absence of the frame and following compensation for field inhomogeneities, measured average CP disposition owing to gradient nonlinearities was 0.53 mm. In presence of the frame, contrarily, detected distortion was greatly increased (up to about 5 mm) in the vicinity of the frame base due to eddy currents induced in the closed loop of its aluminum material. Frame-related distortion was obliterated at approximately 90 mm from the frame base. Although the region with the maximum observed distortion may not lie within the GK treatable volume, the presence of the frame results in distortion of the order of 1.5 mm at a 7 cm distance from the center of the Leksell space. Additionally, severe distortions observed outside the treatable volume could possibly impinge on the delivery accuracy mainly by adversely affecting the registration process (e.g. the position of the lower part of the N-shaped fiducials used to define the stereotactic space may be miss-registered). Images acquired with a modified version of the frame developed by replacing its front side with an acrylic bar, thus interrupting the closed aluminum loop and reducing the induced eddy currents, were shown to benefit from relatively reduced distortion. System-related distortion was also identified in patient MR images. Using corresponding CT angiography images as a reference, an offset of 1.1 mm was detected for two vessels lying in close proximity to the frame base, while excellent spatial agreement was observed for a vessel far apart from the frame base.

26 April 2022 in Cancers
Verified
Journal Article
Open access
PDF file
EVElena Vlastou
Elena Vlastou
EPEvaggelos Pantelis
Evaggelos Pantelis
Efstathios P. EfstathopoulosEfstathios P. Efstathopoulos
Efstathios P. Efstathopoulos
PKPantelis Karaiskos
Pantelis Karaiskos
Vassilis KoulouliasVassilis Kouloulias
Vassilis Kouloulias
Kalliopi-Pola PlatoniKalliopi-Pola Platoni
Kalliopi-Pola Platoni
The recent progress in Nanotechnology has introduced Gold Nanoparticles (AuNPs) as promising radiosensitizing agents in radiation oncology. This work aims to estimate dose enhancement due to the presence of AuNPs inside an irradiated water region through Monte Carlo calculations. The GATE platform was used to simulate 6 MV photon histories generated from a TrueBeam® linear accelerator with and without a Flattening Filter (FF) and model AuNPs clusters. The AuNPs size, concentration and distribution pattern were examined. To investigate different clinical irradiation conditions, the effect of field size, presence of FF and placement of AuNPs in water were evaluated. The range of Dose Enhancement Factors (DEF = DoseAu/DoseWater) calculated in this study is 0.99 ± 0.01–1.26 ± 0.02 depending on photon beam quality, distance from AuNPs surface, AuNPs size and concentration and pattern of distribution. The highest DEF is reported for irradiation using un-flattened photon beams and at close distances from AuNPs. The obtained findings suggest that dose deposition could be increased in regions that represent whole cells or subcellular targets (mitochondria, cell nucleus, etc.). Nevertheless, further and consistent research is needed in order to make a step toward AuNP-aided radiotherapy in clinical practice.

5 September 2017 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
EZE Zoros
E Zoros
AMArgyris Moutsatsos
Argyris Moutsatsos
EPEleftherios P. Pappas
Eleftherios P. Pappas
EGE Georgiou
E Georgiou
GKG Kollias
G Kollias
EPEvaggelos Pantelis
Evaggelos Pantelis
Detector-, field size- and machine-specific correction factors are required for precise dosimetry measurements in small and non-standard photon fields. In this work, Monte Carlo (MC) simulation techniques were used to calculate the k Q m s r , Q 0 f m s r , f r e f and k Q c l i n , Q m s r f c l i n , f m s r correction factors for a series of ionization chambers, a synthetic microDiamond and diode dosimeters, used for reference and/or output factor (OF) measurements in the Gamma Knife Perfexion photon fields. Calculations were performed for the solid water (SW) and ABS plastic phantoms, as well as for a water phantom of the same geometry. MC calculations for the k Q c l i n , Q m s r f c l i n , f m s r correction factors in SW were compared against corresponding experimental results for a subset of ionization chambers and diode detectors. Reference experimental OF data were obtained through the weighted average of corresponding measurements using TLDs, EBT-2 films and alanine pellets. k Q m s r , Q 0 f m s r , f r e f values close to unity (within 1%) were calculated for most of ionization chambers in water. Greater corrections of up to 6.0% were observed for chambers with relatively large air-cavity dimensions and steel central electrode. A phantom correction of 1.006 and 1.024 (breaking down to 1.014 from the ABS sphere and 1.010 from the accompanying ABS phantom adapter) were calculated for the SW and ABS phantoms, respectively, adding up to k Q m s r , Q 0 f m s r , f r e f corrections in water. Both measurements and MC calculations for the diode and microDiamond detectors resulted in lower than unit k Q c l i n , Q m s r f c l i n , f m s r ...