Continuous monitoring by wearable technology is ideal for quantifying mobility outcomes in “real-world” conditions. Concurrent factors such as validity, usability, and acceptability of such technology need to be accounted for when choosing a monitoring device. This study proposes a bespoke methodology focused on defining a decision matrix to allow for effective decision making. A weighting system based on responses (n = 69) from a purpose-built questionnaire circulated within the IMI Mobilise-D consortium and its external collaborators was established, accounting for respondents’ background and level of expertise in using wearables in clinical practice. Four domains (concurrent validity, CV; human factors, HF; wearability and usability, WU; and data capture process, CP), associated evaluation criteria, and scores were established through literature research and group discussions. While the CV was perceived as the most relevant domain (37%), the others were also considered highly relevant (WU: 30%, HF: 17%, CP: 16%). Respondents (~90%) preferred a hidden fixation and identified the lower back as an ideal sensor location for mobility outcomes. Overall, this study provides a novel, holistic, objective, as well as a standardized approach accounting for complementary aspects that should be considered by professionals and researchers when selecting a solution for continuous mobility monitoring.

16 December 2022 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
KSKirsty Scott
Kirsty Scott
TBTecla Bonci
Tecla Bonci
FSFrancesca Salis
Francesca Salis
Lisa AlcockLisa Alcock
Lisa Alcock
EBEllen Buckley
Ellen Buckley
Claudia MazzàClaudia Mazzà
Claudia Mazzà
Background: Measuring mobility in daily life entails dealing with confounding factors arising from multiple sources, including pathological characteristics, patient specific walking strategies, environment/context, and purpose of the task. The primary aim of this study is to propose and validate a protocol for simulating real-world gait accounting for all these factors within a single set of observations, while ensuring minimisation of participant burden and safety. Methods: The protocol included eight motor tasks at varying speed, incline/steps, surface, path shape, cognitive demand, and included postures that may abruptly alter the participants’ strategy of walking. It was deployed in a convenience sample of 108 participants recruited from six cohorts that included older healthy adults (HA) and participants with potentially altered mobility due to Parkinson’s disease (PD), multiple sclerosis (MS), proximal femoral fracture (PFF), chronic obstructive pulmonary disease (COPD) or congestive heart failure (CHF). A novelty introduced in the protocol was the tiered approach to increase difficulty both within the same task (e.g., by allowing use of aids or armrests) and across tasks. Results: The protocol proved to be safe and feasible (all participants could complete it and no adverse events were recorded) and the addition of the more complex tasks allowed a much greater spread in walking speeds to be achieved compared to standard straight walking trials. Furthermore, it allowed a representation of a variety of daily life relevant mobility aspects and can therefore be used for the validation of monitoring devices used in real life. Conclusions: The protocol allowed for measuring gait in a variety of pathological conditions suggests that it can also be used to detect changes in gait due to, for example, the onset or progression of a disease, or due to therapy. Trial registration: ISRCTN—12246987.

9 May 2025 in JMIR Formative Research
Verified
Journal Article
Open access
JLJack Lumsdon
Jack Lumsdon
CWCameron Wilson
Cameron Wilson
Lisa AlcockLisa Alcock
Lisa Alcock
CBClemens Becker
Clemens Becker
FBFrancesco Benvenuti
Francesco Benvenuti
ACAlma Cantu
Alma Cantu
Background: Recent technological advances in wearable devices offer new potential for measuring mobility in real-world contexts. Mobilise-D has validated digital mobility outcomes to provide novel outcomes and end points in clinical research of 4 different long-term health conditions (Parkinson disease, multiple sclerosis, chronic obstructive pulmonary disease, and proximal femoral fracture). These outcomes also provide unique information that is important to patients; however, there is limited literature that explores the optimal methods to achieve this, such as the best way to visualize patients’ data. Objective: This study aimed to identify meaningful outcomes for each condition and how to best visualize them from the perspective of end users. Methods: Using a Delphi-type protocol with patients as subject matter experts, we gathered iterative feedback on the cocreation of visualizations through 3 rounds of questionnaires. An open-ended questionnaire was used in round 1 to understand what aspects of mobility were most influenced by their health condition. These responses were mapped onto relevant digital mobility outcomes and walking experiences and then prioritized for visualization. Using patient responses, we worked alongside researchers, clinicians, and a patient advisory group to develop visualizations that depicted a week of mobility data. During rounds 2 and 3, participants rated usefulness and ease of understanding on a 5-point Likert scale and provided unstructured feedback in comment boxes for each visualization. Visualizations were refined using the feedback from round 2 before receiving further feedback in round 3. Results: Participation varied across rounds 1 to 3 (n=48, n=79, and n=78, respectively). Round 1 identified important outcomes and contexts for each health condition, such as walking speed and stride length for people with Parkinson disease or multiple sclerosis and number of steps for people with chronic obstructive pulmonary disease or proximal femoral fracture. The consensus was not reached for any visualization reviewed in round 2 or 3. Feedback was generally positive, and some participants reported that they were able to understand the visualization and interpret what the visualization represented. Conclusions: Through the feedback provided and existing data visualization principles, we developed recommendations for future visualizations of mobility- and health-related data. Visualizations should be readable by ensuring that large and clear fonts are used and should be friendly for people with vision impairments, such as color blindness. Patients have a strong understanding of their own condition and its variability; hence, adding additional factors into visualizations is recommended to better reflect the nuances of a condition. Ensuring that outcomes and visualizations are meaningful requires close collaboration with patients throughout the development process.

15 October 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
Dimitrios MegaritisDimitrios Megaritis
Dimitrios Megaritis
Lisa AlcockLisa Alcock
Lisa Alcock
KSKirsty Scott
Kirsty Scott
HHHugo Hiden
Hugo Hiden
ANDREA CereattiANDREA Cereatti
ANDREA Cereatti
Silvia Del DinSilvia Del Din
Silvia Del Din
Digital Mobility outcomes can serve as objective biomarkers of health, but their validation in populations with multiple long-term conditions (MLTCs) based on wrist-worn devices remains unexplored. We refined, improved, and introduced novel algorithms, specifically tailored and adapted for (i) gait sequence detection, (ii) initial contact identification, and (iii) stride length estimation from a single wrist-worn device. Validation was performed using data from 28 participants with co-occurring MLTCs performing a 2.5 h real-world monitoring session. Reference data from an established multi-sensor system were used to assess algorithm performance across diverse gait patterns of co-occurring MLTCs. Twenty-eight participants (mean age 70.4 years, 43% females) had a median of three co-occurring MLTCs. Among six gait sequence detection methods, improved versions of the Kheirkhahan algorithm performed best (accuracy = 0.92, specificity = 0.96). For initial contact detection (nine methods tested), Shin’s algorithm achieved the highest performance index (0.85) followed by McCamley (0.84). Stride length estimation was most accurate using novel approaches based on the Weinberg method (performance index > 0.70). The proposed fine-tuned algorithms, the newly developed adaptive variants, and the foot-length augmented versions demonstrated robust performance, surpassing many existing methods and addressing the complexity of gait patterns in MLTCs. These findings enable scalable, real-time mobility monitoring in complex clinical populations using accessible wearable technology.

9 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
KSKirsty Scott
Kirsty Scott
TBTecla Bonci
Tecla Bonci
Lisa AlcockLisa Alcock
Lisa Alcock
EBEllen Buckley
Ellen Buckley
Clint HansenClint Hansen
Clint Hansen
OCon behalf of the Mobilise-D Consortium
on behalf of the Mobilise-D Consortium
Optoelectronic stereophotogrammetric (SP) systems are widely used in human movement research for clinical diagnostics, interventional applications, and as a reference system for validating alternative technologies. Regardless of the application, SP systems exhibit different random and systematic errors depending on camera specifications, system setup and laboratory environment, which hinders comparing SP data between sessions and across different systems. While many methods have been proposed to quantify and report the errors of SP systems, they are rarely utilized due to their complexity and need for additional equipment. In response, an easy-to-use quality control (QC) check has been designed that can be completed immediately prior to a data collection. This QC check requires minimal training for the operator and no additional equipment. In addition, a custom graphical user interface ensures automatic processing of the errors in an easy-to-read format for immediate interpretation. On initial deployment in a multicentric study, the check (i) proved to be feasible to perform in a short timeframe with minimal burden to the operator, and (ii) quantified the level of random and systematic errors between sessions and systems, ensuring comparability of data in a variety of protocol setups, including repeated measures, longitudinal studies and multicentric studies.

2 September 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Dimitrios MegaritisDimitrios Megaritis
Dimitrios Megaritis
Lisa AlcockLisa Alcock
Lisa Alcock
KSKirsty Scott
Kirsty Scott
HHHugo Hiden
Hugo Hiden
ANDREA CereattiANDREA Cereatti
ANDREA Cereatti
Silvia Del DinSilvia Del Din
Silvia Del Din
Digital Mobility outcomes can serve as objective biomarkers of health, but their validation in populations with multiple long-term conditions (MLTC) based on wrist-worn devices remains unexplored. We refined, improved, and introduced novel algorithms, specifically tailored and adapted for i)gait sequence detection, ii)initial contact identification, and iii)stride length estimation from a single wrist-worn device. Validation was performed using data from 28 participants with co-occurring MLTC performing a 2.5-hour real-world monitoring session. Reference data from an established multi-sensor system were used to assess algorithm performance across diverse gait patterns of co-occurring MLTC. Twenty-eight participants (mean age 70.4 years, 43% females) had a median of three co-occurring MLTC. Among six gait sequence detection methods, improved versions of the Kheirkhahan algorithm performed best (accuracy=0.92, specificity=0.96). For initial contact detection (nine methods tested), Shin’s algorithm achieved the highest performance index (0.85) followed by McCamley (0.84). Stride length estimation was most accurate using novel approaches based on the Weinberg method (performance index>0.70). The proposed fine-tuned algorithms, the newly developed adaptive variants, and the foot-length augmented versions, demonstrated robust performance, surpassing many existing methods and addressing the complexity of gait patterns in MLTC. These findings enable scalable, real-time mobility monitoring in complex clinical populations using accessible wearable technology.