Boniface Dominick Mselle

Dr. Boniface Dominick Mselle

Universitat de Lleida
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DFDavid Fernandez
David Fernandez
Emiliano BorriEmiliano Borri
Emiliano Borri
ACAlicia Crespo
Alicia Crespo
Boniface Dominick MselleBoniface Dominick Mselle
Boniface Dominick Mselle
AGAlvaro de Gracia
Alvaro de Gracia
Luisa F. CabezaLuisa F. Cabeza
Luisa F. Cabeza
The use of latent heat thermal energy storage is an effective way to increase the efficiency of energy systems due to its high energy density compared with sensible heat storage systems. The design of the storage material encapsulation is one of the key parameters that critically affect the heat transfer in charging/discharging of the storage system. To fill the gap found in the literature, this paper experimentally investigates the effect of the macro-encapsulation design on the performance of a lab-scale thermal energy storage tank. Two rectangular slabs with the same length and width but different thickness (35 mm and 17 mm) filled with commercial phase change material were used. The results show that using thinner slabs achieved a higher power, leading to a reduction in the charging and discharging time of 14% and 30%, respectively, compared with the thicker slabs. Moreover, the variation of the heat transfer fluid flow rate has a deeper impact on the temperature distribution and the energy charged/released when thicker slabs were used. The macro-encapsulation design did not have a significant impact on the discharging efficiency of the tank, which was around 85% for the operating thresholds considered in this study.

5 July 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Boniface Dominick MselleBoniface Dominick Mselle
Boniface Dominick Mselle
DFDavid Fernandez
David Fernandez
Gabriel ZsembinszkiGabriel Zsembinszki
Gabriel Zsembinszki
Emiliano BorriEmiliano Borri
Emiliano Borri
Luisa F. CabezaLuisa F. Cabeza
Luisa F. Cabeza
This paper experimentally investigates the direct integration of 3.15 kg of phase change materials (PCM) into a standard vapour compression system of variable cooling capacity, through an innovative lab-scale refrigerant-PCM-water heat exchanger (RPW-HEX), replacing the conventional evaporator. Its performance was studied in three operating modes: charging, discharging, and direct heat transfer between the three fluids. In the charging mode, a maximum energy of 300 kJ can be stored in the PCM for the cooling capacity at 30% of the maximum value. By doubling the cooling power, the duration of charging is reduced by 50%, while the energy stored is only reduced by 13%. In the discharging mode, the process duration is reduced from 25 min to 9 min by increasing the heat transfer fluid (HTF) flow rate from 50 L·h−1 to 150 L·h−1. In the direct heat transfer mode, the energy stored in the PCM depends on both the cooling power and the HTF flow rate, and can vary from 220 kJ for a cooling power at 30% and HTF flow rate of 50 L·h−1 to 4 kJ for a compressor power at 15% and a HTF flow rate of 150 L·h−1. The novel heat exchanger is a feasible solution to implement latent energy storage in vapour compression systems resulting to a compact and less complex system.

20 June 2024 in Energies
Verified
Journal Article
Open access
PDF file
LZLaureana Luciani Zabaleta
Laureana Luciani Zabaleta
JCJuliana Cruz
Juliana Cruz
VBVíctor Ballestín
Víctor Ballestín
Boniface Dominick MselleBoniface Dominick Mselle
Boniface Dominick Mselle
The European Union, in pursuit of the goal of reducing emissions by at least 55% by 2030 and achieving climate neutrality by 2050, is deploying different actions, with industry decarbonization as a key strategy. However, increasing electricity demand requires an intensification of energy generation from clean technologies, and the energy system’s expansion is hindered by renewable generation’s climatic dependencies and the imperative for substantial electrical infrastructure investments. Although the transmission grid is expected to grow, flexibility mechanisms and innovative technologies need to be applied to avoid an overwhelming growth. In this context, this paper presents a thorough assessment, conducted within the FLEXINDUSTRIES project, of the flexibility potential across seven energy-intensive industries (automotive industry, biofuel production, polymer manufacturing, steel manufacturing, paper mills, pharmaceutical industry, and cement production). The methodology followed during the analysis entails reviewing the state-of-the-art existing flexibility mechanisms, industries’ energy markets engagement, and technical/operational readiness. The results highlight the feasibility of the proposed actions for enabling energy market flexibility through demand-response programs, quantifying energy opportunities, and pinpointing regulatory and technical barriers.

6 November 2024 in Energies
Verified
Journal Article
Open access
PDF file
JLJosé Manuel Longares
José Manuel Longares
Boniface Dominick MselleBoniface Dominick Mselle
Boniface Dominick Mselle
JGJose Ignacio Gutierrez Galindo
Jose Ignacio Gutierrez Galindo
VBVíctor Ballestín
Víctor Ballestín
This study addresses an identified literature gap regarding indoor environmental quality in residential buildings, where the primary focus has traditionally been on energy performance rather than comfort optimization. Leveraging the low-cost and easy-to-implement LoRaWAN protocol, this research collects and analyses real-time data on comfort parameters, including temperature, CO2 levels, humidity, lighting, atmospheric pressure, and total volatile organic compounds (TVOC) across various buildings within the INCUBE EU project. The results highlight the dynamic nature of the parameters and emphasize the importance of continuous monitoring to enhance comfort and energy efficiency in smart residential buildings. The findings advocate for integrating technologies like LoRaWAN to optimize indoor environmental quality, ultimately improving residential comfort and occupant well-being.

23 January 2025 in Buildings
Verified
Journal Article
Open access
PDF file
JAJuan Aranda
Juan Aranda
Boniface Dominick MselleBoniface Dominick Mselle
Boniface Dominick Mselle
JCJuliana Cruz
Juliana Cruz
YRYassine Rqiq
Yassine Rqiq
JLJosé Manuel Longares
José Manuel Longares
The residential building sector is critical to the success of Europe’s 2030 and 2050 decarbonization targets. To achieve that success, this paper demonstrates how advanced Pay-for-Performance (P4P) energy services for energy service companies (ESCOs) can address challenges by leveraging low-cost data collection systems in buildings to offer a combination of revenues stemming from informed decision-making, energy management optimization, and active participation in demand response schemes. Our methodology includes (i) preliminary assessments to identify each building’s occupancy patterns, equipment, and smart readiness, (ii) the installation of sensors and data gateways, (iii) the deployment of data-driven energy efficiency and demand response measures, and (iv) the evaluation of non-energy services such as comfort and air quality monitoring. We conducted empirical tests in three distinct building typologies: a multi-apartment residential building in Spain, detached dwellings in Croatia, and a hotel bungalow in Greece, to measure self-consumption savings, occupant-driven energy use behaviour changes, and the potential for explicit demand response. The results indicate overall payback periods of less than 10 years, although effectiveness varies depending on occupant engagement, building suitability, and the local energy market context. These findings reinforce the technical and economic feasibility of enhanced ESCO smart services and provide practical insights for scaling up data-driven solutions to advance Europe’s energy and climate objectives.

9 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
Gabriel ZsembinszkiGabriel Zsembinszki
Gabriel Zsembinszki
Boniface Dominick MselleBoniface Dominick Mselle
Boniface Dominick Mselle
DFDavid Fernandez
David Fernandez
Emiliano BorriEmiliano Borri
Emiliano Borri
ASAndreas Strehlow
Andreas Strehlow
Luisa F. CabezaLuisa F. Cabeza
Luisa F. Cabeza
A clear gap was identified in the literature regarding the in-depth evaluation of scaling up thermal energy storage components. To cover such a gap, a new methodological approach was developed and applied to a novel latent thermal energy storage module. The purpose of this paper is to identify some key aspects to be considered when scaling up the module from lab-scale to full-scale using different performance indicators calculated in both charge and discharge. Different normalization methods were applied to allow an appropriate comparison of the results at both scales. As a result of the scaling up, the theoretical energy storage capacity increases by 52% and 145%, the average charging power increases by 21% and 94%, while the average discharging power decreases by 16% but increases by 36% when mass and volume normalization methods are used, respectively. When normalization by the surface area of heat transfer is used, all of the above performance indicators decrease, especially the average discharging power, which decreases by 49%. Moreover, energy performance in charge and discharge decreases by 17% and 15%, respectively. However, efficiencies related to charging, discharging, and round-trip processes are practically not affected by the scaling up.