Andreas  Strehlow

Andreas Strehlow


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
Valeria PalombaValeria Palomba
Valeria Palomba
ABAntonino Bonanno
Antonino Bonanno
GBGiovanni Brunaccini
Giovanni Brunaccini
DADavide Aloisio
Davide Aloisio
FSFrancesco Sergi
Francesco Sergi
Andrea FrazzicaAndrea Frazzica
Andrea Frazzica
The need for innovative heating and cooling systems to decarbonize the building sector is widely recognized. It is especially important to increase the share of renewables at building level by maximizing self-consumption and reducing the primary energy demand. Accordingly, in the present paper, the results on a wide experimental campaign on a hybrid system are discussed. The system included a sorption module working as the topping cycle in a cascade configuration with a DC-driven vapor compression heat pump. A three-fluids heat exchanger with a phase change material (PCM), i.e., RT4 with nominal melting temperature of 4 °C, was installed on the evaporator side of the heat pump, for simultaneous operation as thermal storage and heat pumping purposes. The heat pump was connected to a DC-bus that included PV connection and electricity storage (batteries). Results showed that the energy efficiency of the heat pump in cascade operation was double compared to compression-only configuration and that, when simultaneously charging and discharging the latent storage in cascade configuration, no penalization in terms of efficiency compared to the compression-only configuration was measured. The self-sufficiency of the system was evaluated for three reference weeks in summer conditions of Athens climate and it was found that up to 100% of the electricity needed to drive the system could be self-produced for a modest cooling demand and up to 67% for the warmer conditions with high cooling demand.

6 November 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JEJohann Emhofer
Johann Emhofer
KMKlemens Marx
Klemens Marx
TBTilman Barz
Tilman Barz
FHFelix Hochwallner
Felix Hochwallner
Luisa F. CabezaLuisa F. Cabeza
Luisa F. Cabeza
Werner PinkWerner Pink
Werner Pink
Integration of a three-media refrigerant/phase change material (PCM)/water heat exchanger (RPW-HEX) in the hot superheated section of a heat pump (HP) system is a promising approach to save energy for domestic hot water (DHW) generation in multi-family houses. The RPW-HEX works as a desuperheater and as a latent thermal energy storage in the system. The latent thermal energy storage is charged during heating and cooling operation and discharged for DHW production. For this purpose, the water side of the RPW-HEX is connected to decentralized DHW storage devices. DHW consumption, building standards and climate, energy prices, material costs, and production costs are the constraints for the selection of the optimal storage size and RPW-HEX design. This contribution presents the techno-economic analysis of the RPW-HEX integrated into an R32 air source HP. With the aid of experimentally validated dynamic computer models, the optimal sizing of the RPW-HEX storage is discussed to maximize energy savings and to minimize the investment costs. The results are discussed in the context of a return of investment analysis, practical implementation aspects and energetic potential of the novel technology.

9 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
Gabriel ZsembinszkiGabriel Zsembinszki
Gabriel Zsembinszki
Boniface Dominick MselleBoniface Dominick Mselle
Boniface Dominick Mselle
DFDavid Fernandez
David Fernandez
Emiliano BorriEmiliano Borri
Emiliano Borri
ASAndreas Strehlow
Andreas Strehlow
Luisa F. CabezaLuisa F. Cabeza
Luisa F. Cabeza
A clear gap was identified in the literature regarding the in-depth evaluation of scaling up thermal energy storage components. To cover such a gap, a new methodological approach was developed and applied to a novel latent thermal energy storage module. The purpose of this paper is to identify some key aspects to be considered when scaling up the module from lab-scale to full-scale using different performance indicators calculated in both charge and discharge. Different normalization methods were applied to allow an appropriate comparison of the results at both scales. As a result of the scaling up, the theoretical energy storage capacity increases by 52% and 145%, the average charging power increases by 21% and 94%, while the average discharging power decreases by 16% but increases by 36% when mass and volume normalization methods are used, respectively. When normalization by the surface area of heat transfer is used, all of the above performance indicators decrease, especially the average discharging power, which decreases by 49%. Moreover, energy performance in charge and discharge decreases by 17% and 15%, respectively. However, efficiencies related to charging, discharging, and round-trip processes are practically not affected by the scaling up.

10 February 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Boniface Dominick MselleBoniface Dominick Mselle
Boniface Dominick Mselle
Gabriel ZsembinszkiGabriel Zsembinszki
Gabriel Zsembinszki
DFDavid Fernandez
David Fernandez
Emiliano BorriEmiliano Borri
Emiliano Borri
ASAndreas Strehlow
Andreas Strehlow
Luisa F. CabezaLuisa F. Cabeza
Luisa F. Cabeza
This study was carried out within the HYBUILD project, as part of the task aimed at developing novel evaporators for compact and direct integration of phase-change materials (PCM) into air-conditioning systems for efficient utilization of solar energy. To achieve this, novel evaporators were designed to contain PCM between refrigerant and heat transfer fluid (HTF) channels, allowing a three-media heat exchange mechanism. This paper experimentally assesses the influence of the configuration/arrangement of the channels on the performance of the evaporators, using three different lab-scale prototypes. Key performance indicators (KPI) relevant for thermal energy storage (TES) and heat exchangers (HEX) were used to study the influence of the design on the performance of the different designs of the novel evaporators. The results show that the change in the PCM, refrigerant, and HTF channel configuration affects the performance of the novel evaporators independently. The coefficient of performance (COP) of the refrigeration system and the energy storage density of the modules are the least affected KPIs (less than 16%), whereas the state of charge (SOC) at thermal equilibrium is the most affected KPI (about 44%). A discussion on how these effects provide unique strength for specific applications is included.