Mahmoud F. Mubarak

Mahmoud F. Mubarak


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2023 in Environmental Science and Pollution Research
Verified
Journal Article
Open access
PDF file
MMMahmoud F. Mubarak
Mahmoud F. Mubarak
HSHanaa Selim
Hanaa Selim
HHHamada B. Hawash
Hamada B. Hawash
MHMohamed Hemdan
Mohamed Hemdan
In this study, we developed a novel nanocomposite-based membrane using maghemite copper oxide (MC) to enhance the separation efficiency of poly(vinyl chloride) (PVC) membranes for oil-in-water emulsions. The MC nanocomposite was synthesized using a co-precipitation method and incorporated into a PVC matrix by casting. The resulting nanocomposite-based membrane demonstrated a high degree of crystallinity and well-dispersed nanostructure, as confirmed by TEM, SEM, XRD, and FT-IR analyses. The performance of the membrane was evaluated in terms of water flux, solute rejection, and anti-fouling properties. The pinnacle of performance was unequivocally reached with a solution dosage of 50 mL, a solution concentration of 100 mg L−1, and a pump pressure of 2 bar, ensuring that every facet of the membrane’s potential was fully harnessed. The new fabricated membrane exhibited superior efficiency for oil–water separation, with a rejection rate of 98% and an ultra-high flux of 0.102 L/m2 h compared to pure PVC membranes with about 90% rejection rate and an ultra-high flux of 0.085 L/m2 h. Furthermore, meticulous contact angle measurements revealed that the PMC nanocomposite membrane exhibited markedly lower contact angles (65° with water, 50° with ethanol, and 25° with hexane) compared to PVC membranes. This substantial reduction, transitioning from 85 to 65° with water, 65 to 50° with ethanol, and 45 to 25° with hexane for pure PVC membranes, underscores the profound enhancement in hydrophilicity attributed to the heightened nanoparticle content. Importantly, the rejection efficiency remained stable over five cycles, indicating excellent anti-fouling and cycling stability. The results highlight the potential of the maghemite copper oxide nanocomposite-based PVC membrane as a promising material for effective oil-in-water emulsion separation. This development opens up new possibilities for more flexible, durable, and anti-fouling membranes, making them ideal candidates for potential applications in separation technology. The presented findings provide valuable information for the advancement of membrane technology and its utilization in various industries, addressing the pressing challenge of oil-induced water pollution and promoting environmental sustainability. Graphical Abstract


7 June 2022 in RSC Advances
Verified
Journal Article
Open access
PDF file
ASAbeer El Shahawy
Abeer El Shahawy
MMMahmoud F. Mubarak
Mahmoud F. Mubarak
MSMerna El Shafie
Merna El Shafie
HAHesham Abdulla
Hesham Abdulla
Heavy metal ions in water refer to significant risks to the biological system due to their high toxicity. Therefore, the decontamination of water polluted by heavy metal ions attracts significant interest of researchers. Adsorption by nanomaterials has been a widely used technique for removing heavy metal ions from water. Chitosan was extracted from shrimp shellfish and mixed with laboratory-prepared AgNPs/GO in the ratio of 3 : 1. A series of tests evaluates the best condition of pH, amount of adsorbent, retention time, stirring speed, temp, and initial concentration. The research was conducted under various conditions. Langmuir, Freundlich, Tempkin, and Dubinin–Radushkevich isotherms were also tested. Also, the column adsorption experiment was carried out on industrial wastewater at different flow rates and column bed heights. The optimal values of the contact time, pH, and adsorbent dose of Cr(VI) were found to be 80 min, 4, and 0.1 g 100 mL−1, respectively, at room temperature (30 °C), agitation at 150 rpm, and initial concentration of 50 ppm. On the other hand, the optimal value of contact time, pH, and adsorbent dose of Fe(III) were found to be 30 min, 6, and 0.02 g 100 mL−1, respectively, at room temp (30 °C) with a stirring speed of 250 rpm and an initial concentration of 40 ppm. For Cr(VI) and Fe(III), equilibrium studies show that the data fit the Freundlich isotherm well (correlation coefficient, R2 = 0.98) (III). A link between the pseudo-second order active model and data fitting the pseudo-first order active models were made. Within the intraparticle diffusion model, there are four stages that the mechanism must go through before it is at equilibrium. The adsorbent was tested in an industrial adsorbent column. This test proves that the nanocomposite's adsorption capacity can be restored by washing it with 0.1 M HCl, as shown by the periodicity test. After four cycles, the amount of Cr(VI) adsorbed on AgNPs/GO/chitosan was just 20%, which is insufficient for further adsorption experiments. Cr(VI) removal rates (%R) decreased slightly.

11 October 2022 in RSC Advances
Verified
Journal Article
Open access
PDF file
ASAbeer El Shahawy
Abeer El Shahawy
MMMahmoud F. Mubarak
Mahmoud F. Mubarak
MSMerna El Shafie
Merna El Shafie
HAHesham Abdulla
Hesham Abdulla
Water contaminated with heavy metal ions is extremely poisonous and threatens living organisms. Therefore, scientists place a premium on removing heavy metal ions from water that has already been contaminated. Removing metal ions from water typically involves the use of nanomaterials. Chitosan was made by extracting it from shrimp shells and combining it with a 3 : 1 ratio of synthetically produced AgNPs/GO. Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) with transmission electron microscopy (TEM), and X-ray diffraction were used to investigate an AgNPs/GO/chitosan nanocomposite (XRD). A number of studies must be run to determine the optimal pH, adsorbent quantity, retention period, stirring speed, temperature, and initial concentration. The studies were conducted in a variety of ways. The isotherms of Langmuir, Freundlich, and Dubinin–Radushkevich were utilized. The industrial wastewater was used in the column adsorption experiment, and the flow rates and column bed heights were varied. An optimum contact time, pH, and adsorbent dosage for Mn(II) were determined. At 30 minutes, pH 6, and 0.05 grams of Mn(II) adsorbent per 100 ml, with agitation at 250 rpm, room temperature of 30 °C, and an initial concentration of 40 ppm, the best conditions were discovered. A positive correlation coefficient finding (R2 = 0.925) indicates a good fit for Mn, according to equilibrium studies (II). The pseudo-second-order active model was connected to data that suited the pseudo-first and pseudo-second-order models. In the intra-particle diffusion model, the mechanism must proceed through four phases before equilibrium is reached. In an industrial adsorbent column, the adsorbent was put to the test. The periodicity test demonstrates that the nanocomposite's adsorption capability can be recovered by washing it with 0.1 M HCl. Mn(II) adsorbed on AgNPs/GO/Chitosan after four cycles was only 20%, insufficient for additional adsorption tests. The repeated cycles that led to the partial loss of the adsorbate may have reduced the adsorbent material's efficacy.

4 November 2021 in Membranes
Verified
Journal Article
Open access
PDF file
SASaedah Rwede AL-Mhyawi
Saedah Rwede AL-Mhyawi
MMMahmoud F. Mubarak
Mahmoud F. Mubarak
Rasha HosnyRasha Hosny
Rasha Hosny
MAManal Amine
Manal Amine
OAOmnia H. Abdelraheem
Omnia H. Abdelraheem
ASAbeer El Shahawy
Abeer El Shahawy
This research studied the enhancing effect on the nanofiltration composite (TFCNF) membrane of two non-ionic surfactants on a thin-film composite nanofiltration membrane (TFCNF) for calcite scale (CaCO3) inhibition in oilfield application to develop a multifunctional filtration system: nanofiltration, antiscalant, and scale inhibitors. The effectiveness of dodecyl phenol ethoxylate (DPE) and oleic acid ethoxylate (OAE) as novel scale inhibitors were studied using the dynamic method. Scaling tests on the membrane were performed to measure the scaling of the inhibited membrane with and without scale inhibitors for salt rejection, permeability, and flux decline. The results revealed that the TFCNF membrane flux decline was improved in the presence of scale inhibitors from 22% to about 15%. The rejection of the membrane scales increases from 72% for blank membranes, reaching 97.2% and 88% for both DPE and OAE, respectively. These confirmed that scale inhibitor DPE had superior anti-scaling properties against calcite deposits on TFCNF membranes. Inhibited scaled TFCNF membrane was characterized using environmental scanning electron (ESEM), FTIR, and XRD techniques. The results of the prepared TFCNF membrane extensively scaled by the calcite deposits were correlated to its morphology.

10 April 2023 in Egyptian Journal of Chemistry
Verified
Journal Article
Closed access
RHRasha hosny
Rasha hosny
AMAtef Mohamed Gad Mohamed
Atef Mohamed Gad Mohamed
OAOh Abdelraheem
Oh Abdelraheem
MHModather F. Hussein
Modather F. Hussein
MMMahmoud F. Mubarak
Mahmoud F. Mubarak
HAHanan A. Ahmed
Hanan A. Ahmed
This paper studies the removal of ethyl naphthalene as one of the polyaromatic hydrocarbon pollutants (PAHs) from the produced water. Magnetic super hydrophobic monolithic core-shell polystyrene (MSHMCSh@PS) was prepared using a simple and low-cost (facile in situ bulk radical polymerization) method, in the presence of 2-azobisisobutyronitrile as an initiator for ethyl naphthalene adsorption. The characterization of the MSHMCSh@PS was performed using FT-IR, TGA, SEM, TEM, and VSM. The possibility of PAHs adsorption from produced water was performed using the continuous adsorption study in a fixed-bed column. The effects of flow rate, concentration, and bed height were investigated. The results showed that the relationship between adsorption capacity with both inlet concentration and bed depth is a direct one, while the relationship between adsorption capacity and flow rate is an inverse relationship. The best column parameters were found at 2.5 ml/min flowing rate, 9 cm bed height, and 50 mg/L concentration. The experimental column results and the relationship between operating boundaries were analyzed according to Yoon-Nelson and Thomas models. The results indicated that the breakthrough curve follows the Yoon-Nelson model. The practical application results showed that the PAHs were adsorbed from the produced water using the prepared absorbent MSHMCSh@PS, which was distinguished by its superior ability.