Frank Tittel

Dr. Frank Tittel

Electrical and Computer Engineering Department, Rice University MS 366, Houston, TX 77251-1892, USA
orcid

Research Focus & Metrics

Academic Career Length

39Years (1988-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2014 in Sensors
Verified
Journal Article
Open access
PDF file
Pietro PatimiscoPietro Patimisco
Pietro Patimisco
Gaetano ScamarcioGaetano Scamarcio
Gaetano Scamarcio
Frank TittelFrank Tittel
Frank Tittel
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
A detailed review on the development of quartz-enhanced photoacoustic sensors (QEPAS) for the sensitive and selective quantification of molecular trace gas species with resolved spectroscopic features is reported. The basis of the QEPAS technique, the technology available to support this field in terms of key components, such as light sources and quartz-tuning forks and the recent developments in detection methods and performance limitations will be discussed. Furthermore, different experimental QEPAS methods such as: on-beam and off-beam QEPAS, quartz-enhanced evanescent wave photoacoustic detection, modulation-cancellation approach and mid-IR single mode fiber-coupled sensor systems will be reviewed and analysed. A QEPAS sensor operating in the THz range, employing a custom-made quartz-tuning fork and a THz quantum cascade laser will be also described. Finally, we evaluated data reported during the past decade and draw relevant and useful conclusions from this analysis.

8 December 2007 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
AKA. Kosterev
A. Kosterev
GWG. Wysocki
G. Wysocki
YBY. Bakhirkin
Y. Bakhirkin
SSS. So
S. So
RLR. Lewicki
R. Lewicki
RCR.F. Curl
R.F. Curl

14 November 2007
Verified
Book Chapter
Closed access
PDF file
Frank TittelFrank Tittel
Frank Tittel
DRDirk Richter
Dirk Richter
AFAlan Fried
Alan Fried

10 April 2004 in Applied Optics
Verified
Journal Article
Closed access
PDF file
YBYury A. Bakhirkin
Yury A. Bakhirkin
AKAnatoliy A. Kosterev
Anatoliy A. Kosterev
CRChad Roller
Chad Roller
RCRobert F. Curl
Robert F. Curl
Frank TittelFrank Tittel
Frank Tittel
Tunable-laser absorption spectroscopy in the mid-IR spectral region is a sensitive analytical technique for trace-gas quantification. The detection of nitric oxide (NO) in exhaled breath is of particular interest in the diagnosis of lower-airway inflammation associated with a number of lung diseases and illnesses. A gas analyzer based on a continuous-wave mid-IR quantum cascade laser operating at ∼5.2 μm and on off-axis integrated cavity output spectroscopy (ICOS) has been developed to measure NO concentrations in human breath. A compact sample cell, 5.3 cm in length and with a volume of <80 cm3, that is suitable for on-line and off-line measurements during a single breath cycle, has been designed and tested. A noise-equivalent (signal-to-noise ratio of 1) sensitivity of 10 parts in 109 by volume (ppbv) of NO was achieved. The combination of ICOS with wavelength modulation resulted in a 2-ppbv noise-equivalent sensitivity. The total data acquisition and averaging time was 15 s in both cases. The feasibility of detecting NO in expired human breath as a potential noninvasive medical diagnostic tool is discussed.

9 November 2006 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
RLR. Lewicki
R. Lewicki
GWG. Wysocki
G. Wysocki
AKA.A. Kosterev
A.A. Kosterev
Frank TittelFrank Tittel
Frank Tittel

27 September 2017 in Sensors
Verified
Journal Article
Open access
PDF file
MDMing Dong
Ming Dong
Chuantao ZhengChuantao Zheng
Chuantao Zheng
SMShuzhuo Miao
Shuzhuo Miao
YZYu Zhang
Yu Zhang
QDQiaoling Du
Qiaoling Du
Frank TittelFrank Tittel
Frank Tittel
A multi-gas sensor system was developed that uses a single broadband light source and multiple carbon monoxide (CO), carbon dioxide (CO2) and methane (CH4) pyroelectric detectors by use of the time division multiplexing (TDM) technique. A stepper motor-based rotating system and a single-reflection spherical optical mirror were designed and adopted to realize and enhance multi-gas detection. Detailed measurements under static detection mode (without rotation) and dynamic mode (with rotation) were performed to study the performance of the sensor system for the three gas species. Effects of the motor rotating period on sensor performances were also investigated and a rotation speed of 0.4π rad/s was required to obtain a stable sensing performance, corresponding to a detection period of ~10 s to realize one round of detection. Based on an Allan deviation analysis, the 1σ detection limits under static operation are 2.96, 4.54 and 2.84 parts per million in volume (ppmv) for CO, CO2 and CH4, respectively and the 1σ detection limits under dynamic operations are 8.83, 8.69 and 10.29 ppmv for the three gas species, respectively. The reported sensor has potential applications in various fields requiring CO, CO2 and CH4 detection such as in coal mines.