A multi-gas sensor system was developed that uses a single broadband light source and multiple carbon monoxide (CO), carbon dioxide (CO2) and methane (CH4) pyroelectric detectors by use of the time division multiplexing (TDM) technique. A stepper motor-based rotating system and a single-reflection spherical optical mirror were designed and adopted to realize and enhance multi-gas detection. Detailed measurements under static detection mode (without rotation) and dynamic mode (with rotation) were performed to study the performance of the sensor system for the three gas species. Effects of the motor rotating period on sensor performances were also investigated and a rotation speed of 0.4π rad/s was required to obtain a stable sensing performance, corresponding to a detection period of ~10 s to realize one round of detection. Based on an Allan deviation analysis, the 1σ detection limits under static operation are 2.96, 4.54 and 2.84 parts per million in volume (ppmv) for CO, CO2 and CH4, respectively and the 1σ detection limits under dynamic operations are 8.83, 8.69 and 10.29 ppmv for the three gas species, respectively. The reported sensor has potential applications in various fields requiring CO, CO2 and CH4 detection such as in coal mines.
This study describes the basic principles of optical waveguide refractive index sensing and the various design structures of refractive index sensors. These waveguides generate different optical resonances, which cause changes in the sensing refractive index and temperature and are subsequently used to detect the concentration in the analyses. First, the structural characteristics and performance indices of the microring sensor and interferometer are studied based on the refractive index of the optical waveguide. Second, the principle and sensing detection mechanism of the two types of refractive index sensing employed in these sensors are analyzed. Then, the two sensors are classified and discussed from the perspective of the waveguide materials and structures, as well as the substances to be measured. Simultaneously, performance indicators such as sensitivity and detection range are compared and summarized. The comparison results show that there is a compromise between the sensitivity and quality factor of the optical waveguide refractive index sensor. Finally, applications of refractive index sensing in the biochemical field for material detection are discussed, showing that the optical waveguide refractive index sensor has significant advantages over other types of biochemical optical sensors.
A continuous-wave (CW) interband cascade laser (ICL) based mid-infrared sensor system was demonstrated for simultaneous detection of atmospheric methane (CH4) and ethane (C2H6). A 3.337 µm CW ICL with an emitting wavenumber range of 2996.0−3001.5 cm−1 was used to simultaneously target two absorption lines, C2H6 at 2996.88 cm−1 and CH4 at 2999.06 cm−1, respectively. The sensor performance was first evaluated for single-gas detection by only targeting the absorption line of one gas species. Allan deviations of 11.2 parts per billion in volume (ppbv) for CH4 and 1.86 ppbv for C2H6 with an averaging time of 3.4 s were achieved for the detection of these two gases. Dual-gas detection was realized by using a long-term scan signal to target both CH4 and C2H6 lines. The Allan deviations increased slightly to 17.4 ppbv for CH4 and 2.4 ppbv for C2H6 with an averaging time of 4.6 s due to laser temperature and power drift caused by long-term wavelength scanning. Measurements for both indoor and outdoor concentration changes of CH4 and C2H6 were conducted. The reported single ICL based dual-gas sensor system has the advantages of reduced size and cost compared to two separate sensor systems.
Design and fabrication of a dual spot-ring Herriott cell (DSR-HC) were proposed. The sealed Herriott cell with a dimensional size of 5.5 cm × 9.2 cm × 32.1 cm, possessed two input/output coupling holes leading to two absorption path lengths of ~20 m and ~6 m, respectively. An acetylene (C2H2) sensor system with a double-range was developed using the DSR-HC and wavelength modulation spectroscopy (WMS) technique. A near-infrared distributed feedback (DFB) laser was employed for targeting a C2H2 absorption line at 6521.2 cm−1. C2H2 concentration measurements were carried out by modulating the laser at a 5 kHz frequency and demodulating the detector signal with LabVIEW software. An Allan-Werle deviation analysis indicated that the limit of detection (LoD) for the two absorption path lengths of 20 m and 6 m are 7.9 parts-per-million in volume (ppmv) and 4.0 ppmv, respectively. The DSR-HC concept can be used to fabricate similar cells for single-gas detection requiring two different detection ranges as well as for dual-gas detection requiring different absorption path lengths.
1 April 2022 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy