Hossam F Jokhadar

Dr. Hossam F Jokhadar


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2023 in Medicina
Verified
Journal Article
Open access
PDF file
SJSaurabh Jain
Saurabh Jain
Mohammed SayedMohammed Sayed
Mohammed Sayed
WIWael Ibraheem
Wael Ibraheem
AAAbrar A. Ageeli
Abrar A. Ageeli
SGSumir Gandhi
Sumir Gandhi
YYahya Aljabri
Yahya Aljabri
Background and Objectives: The present systematic review and meta-analysis undertake a comparison of studies that examine the accuracy of robot-assisted dental implant placement in relation to static computer-assisted implant surgery (SCAIS), dynamic computer-assisted implant surgery (DCAIS), and freehand procedures. This study aims to provide a comprehensive understanding of the precision of robot-assisted dental implant placement and its comparative efficacy in relation to other placement techniques. Methods: The guidelines recommended by Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) were used to organize and compose this review. Four electronic databases (PubMed, Web of Science, Scopus, and Cochrane) were systematically searched for pertinent articles. Articles were selected following the inclusion and exclusion criteria. Qualitative and quantitative analyses of the selected articles were performed. Results: The initial electronic search resulted in 1087 hits. Based on the inclusion and exclusion criteria, five articles were selected for qualitative analysis, out of which three were considered for quantitative analysis. Three parameters were considered for accuracy evaluation (angular, coronal, and apical deviation). The mean angular deviation was −1.22 degrees (95% CI, −1.06–−1.39), the mean coronal deviation was −0.15 mm (95% CI, −0.24–−0.07), and the mean apical deviation was −0.19 mm (95% CI, −0.27–−0.10). Conclusions: The robotic implant system was found to have significantly lower angular deviations and insignificantly lower coronal and apical deviations compared to DCAIS. Within the limitations of this review, it can be concluded that robot-assisted implant placement in resin models permits higher accuracy compared to DCAIS and SCAIS systems. However, due to the limited number of comparative studies with high heterogeneity, the findings of this review should be interpreted with caution. Further research is necessary to confirm the clinical application of robotics in implant surgery.

8 February 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
MMMaryam Mugri
Maryam Mugri
SJSaurabh Jain
Saurabh Jain
Mohammed SayedMohammed Sayed
Mohammed Sayed
AHAmjad Halawi
Amjad Halawi
SHSafa Ahmed Ibrahim Hamzi
Safa Ahmed Ibrahim Hamzi
DLDr.Honey Lunkad
Dr.Honey Lunkad
Tobacco consumption in its different forms can affect the optical and surface properties of dental materials that are used in the oral cavity. Thus, the present study was conducted to evaluate the effects of two commercially available smokeless tobacco products on the color stability and surface roughness of denture base resins that were fabricated using three different techniques (CAD/CAM milling, 3D printing, and conventional heat polymerization). A total of 126 denture base resin specimens were fabricated using the three different manufacturing techniques (n = 42 each). Specimens from each group were further subdivided into three subgroups (n = 14 each) and immersed in three different immersion media (a khaini suspension, a tabbaq suspension, and artificial saliva). The differences in color and surface roughness were assessed according to data that were collected and statistically analyzed using SPSS version 24.0. The tabbaq smokeless tobacco was found to cause greatest changes in color and surface roughness; the effect was observed to be highest in the 3D-printed specimens followed by the conventional heat-polymerized and CAD/CAM milled specimens. The mean changes in color and surface roughness were the highest for the tabbaq smokeless tobacco followed by the khaini smokeless tobacco and the artificial saliva. Statistically significant (p-value < 0.05) differences were observed among all techniques and suspensions. We concluded that the mean changes in color and surface roughness were significantly higher for the 3D-printed dentures compared to the conventional heat-polymerized and CAD/CAM-milled dentures. Thus, the results of the present study strengthened the concept that tobacco in any form can lead to changes in the color and surface roughness of denture base materials.

31 October 2023 in Polymers
Verified
Journal Article
Open access
PDF file
HDHarisha Dewan
Harisha Dewan
Mohammed SayedMohammed Sayed
Mohammed Sayed
AJAsayil Jundus
Asayil Jundus
MGMafaz Gharawi
Mafaz Gharawi
SBSafeyah Baeshen
Safeyah Baeshen
AMAlkhansa Moafa
Alkhansa Moafa
The aim of this study was to assess the shear bond strength of 3D-printed and milled provisional restorations using various resin materials and surface finishes. There were 160 preliminary samples in all, and they were split into two groups: the milled group and the 3D-printed group. Based on the resin used for repair (composite or polymethylmethacrylate (PMMA)) and the type of surface treatment utilized (chemical or mechanical), each group was further divided into subgroups. The specimens were subjected to thermocycling from 5 °C to 55 °C for up to 5000 thermal cycles with a dwell time of 30 s. The mechanical qualities of the repaired material underwent testing for shear bond strength (SBS). To identify the significant differences between the groups and subgroups, a statistical analysis was carried out. Three-way ANOVA was used to analyze the effects of each independent component (the material and the bonding condition), as well as the interaction between the independent factors on shear bond strength. Tukey multiple post-hoc tests were used to compare the mean results for each material under various bonding circumstances. The shear bond strengths of the various groups and subgroups differed significantly (p < 0.05). When compared to the milled group, the 3D-printed group had a much greater mean shear bond strength. When compared to PMMA repair, the composite resin material showed a noticeably greater shear bond strength. In terms of surface treatments, the samples with mechanical and chemical surface treatments had stronger shear bonds than those that had not received any. The results of this study demonstrate the effect of the fabrication method, resin type, and surface treatment on the shear bond strength of restored provisional restorations. Particularly when made using composite material and given surface treatments, 3D-printed provisional restorations showed exceptional mechanical qualities. These results can help dentists choose the best fabrication methods, resin materials, and surface treatments through which to increase the durability and bond strength of temporary prosthesis.

15 February 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
MMMaryam Mugri
Maryam Mugri
HDHarisha Dewan
Harisha Dewan
Mohammed SayedMohammed Sayed
Mohammed Sayed
FSFawzia Ibraheem Shaabi
Fawzia Ibraheem Shaabi
HHHanan Ibrahim Hakami
Hanan Ibrahim Hakami
HCHitesh Chohan
Hitesh Chohan
The aim of this study is to investigate the combined effect of a digital manufacturing technique (subtractive vs. additive), preparation taper (10° vs. 20° TOC), and finish line (chamfer vs. shoulder) on the marginal adaptation of temporary crowns following cementation with a compatible temporary cement. Four mandibular first molar typodont teeth were prepared for full coverage crowns with standard 4 mm preparation height as follows: 10° TOC with the chamfer finish line, 10° TOC with the shoulder finish line, 20° TOC with the chamfer finish line and 20° TOC with the shoulder finish line. Each of the four preparation designs were subdivided into two subgroups to receive CAD/CAM milled and 3D-printed crowns (n = 10). A total of 80 temporary crowns (40 CAD/CAM milled and 40 3D-printed) were cemented to their respective die using clear temporary recement in the standard cementation technique. The samples were examined under a stereomicroscope at ×100 magnification following calibration. Linear measurements were performed at seven equidistant points on each axial surface and five equidistant points on each proximal surface. One-way ANOVA analysis and Tukey HSD (Honestly Significance Difference) were performed. The best marginal fit was seen in group 8, while the poorest fit was noted in group 2. Shoulder finish lines and 10° TOC resulted in higher marginal gaps, especially in CAD/CAM milled group. The selection of 3D-printed crowns may provide a better marginal fit within the range of clinical acceptability. Marginal gaps were within clinical acceptability (50 and 120 µm) in all groups except group 2.

30 June 2023 in Medical Science Monitor
Verified
Journal Article
Open access
SGShekhar Gupta
Shekhar Gupta
Mohammed SayedMohammed Sayed
Mohammed Sayed
BGBharti Gupta
Bharti Gupta
APAditya Patel
Aditya Patel
KMKhurshid Mattoo
Khurshid Mattoo
Shankargouda PatilShankargouda Patil
Shankargouda Patil
BACKGROUND This study aimed to compare a composite resin (Duo-Shade) shade guide with Vita ceramic shades before/after chemical and autoclave sterilization. MATERIAL AND METHODS Color values (L*a*b*) were recorded directly from shade tabs of prefabricated composite resin (Brilliant NG Universal Duo-Shade) and ceramic (Vita classic) shade guide with a calibrated spectrophotometer (Vita Easy Shade Advance 4.0). Seventy-two composite resin disk samples with 6 different shades (A1/B1, A2/B2, A3/D3, A3.5/B3, A4/C4, and C2/C3) (n=12 each) were divided into 2 groups (Gp) - Gp A (Autoclave) and Gp C (Chemical) (15 cycles) - to assess their influence on respective shades. Mean values calculated the color differences (ΔE) while differences in color values (L*a*b*) were graded on the National Bureau of Standards (NBS) 6-grade scale and assessed for Clinical Acceptance/Perceptible Threshold (CAT), (CPT). All differences were considered significant if the color difference ΔE was ≥3.3. RESULTS Only 2 out of 12 Shade tabs (C2C3, A4C4) of composite resin matched to Vita shade tab C2 and C4 (ΔE ≤3.3). Both groups showed notable color differences after respective sterilization protocols, with color differences in Gp A significantly higher than Gp C (DE ³3.3). Within groups, all shades in Gp A showed remarkably different color changes, with shade C2C3 and A1B1 being denoted as clinically unacceptable. CONCLUSIONS Manufacturer-provided shade guides do not match ceramic shades as claimed and chemical sterilization using 10% Deconex was associated with less color changes than with autoclave sterilization.

17 January 2024 in Medical Science Monitor
Verified
Journal Article
Open access
Mohammed SayedMohammed Sayed
Mohammed Sayed
APAmit Porwal
Amit Porwal
BHBassam Ali Hamdi
Bassam Ali Hamdi
SHSalman Y. Hurubi
Salman Y. Hurubi
AHAbdulwahab Khalid Hakami
Abdulwahab Khalid Hakami
SASaad AlResayes
Saad AlResayes
BACKGROUND Several auxiliary features have been proposed to achieve sustainable retention for short-prepared dental crowns; however, achieving retention is challenging. This study aimed to assess the impact of increased total occlusal convergence and auxiliary preparation factors like box and groove on the retention form of short tooth preparations. MATERIAL AND METHODS Eighty resin machine-milled dies with a height of 3 mm and a deep chamfer margin of 1 mm were prepared to mimic the short-prepared molar. Initially, 2 teeth were prepared following the guidelines, and the total occlusal convergence was kept at 10° and 20°, respectively. Auxiliary features such as the proximal box and buccal groove were prepared on separate 20° dies. Eighty dies were prepared with 10 samples each for 10°, 20°, 20° with proximal box and 20° with buccal groove for zirconia (n=40) and metal crowns (n=40). Cementation was done with glass ionomer luting cement, and a pull-off test was conducted. Data were analyzed using one-way analysis of variance and post hoc fisher least significant difference test (P<0.05). RESULTS The highest mean was observed in the proximal box group with the metal crown (14.59), and the lowest in the group with 20° zirconia crowns (9.12). Within groups, the highest retentive values were found for the 20° taper with proximal box preparation; the lowest was for the 20° taper group. CONCLUSIONS Within the study limitations, it could be concluded that incorporating a proximal box or buccal groove in short tooth preparations with an increased total occlusal convergence improved retentive values.