Saad AlResayes

Dr. Saad AlResayes

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2023 in Medicina
Verified
Journal Article
Open access
PDF file
SJSaurabh Jain
Saurabh Jain
Mohammed SayedMohammed Sayed
Mohammed Sayed
WIWael Ibraheem
Wael Ibraheem
AAAbrar A. Ageeli
Abrar A. Ageeli
SGSumir Gandhi
Sumir Gandhi
YYahya Aljabri
Yahya Aljabri
Background and Objectives: The present systematic review and meta-analysis undertake a comparison of studies that examine the accuracy of robot-assisted dental implant placement in relation to static computer-assisted implant surgery (SCAIS), dynamic computer-assisted implant surgery (DCAIS), and freehand procedures. This study aims to provide a comprehensive understanding of the precision of robot-assisted dental implant placement and its comparative efficacy in relation to other placement techniques. Methods: The guidelines recommended by Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) were used to organize and compose this review. Four electronic databases (PubMed, Web of Science, Scopus, and Cochrane) were systematically searched for pertinent articles. Articles were selected following the inclusion and exclusion criteria. Qualitative and quantitative analyses of the selected articles were performed. Results: The initial electronic search resulted in 1087 hits. Based on the inclusion and exclusion criteria, five articles were selected for qualitative analysis, out of which three were considered for quantitative analysis. Three parameters were considered for accuracy evaluation (angular, coronal, and apical deviation). The mean angular deviation was −1.22 degrees (95% CI, −1.06–−1.39), the mean coronal deviation was −0.15 mm (95% CI, −0.24–−0.07), and the mean apical deviation was −0.19 mm (95% CI, −0.27–−0.10). Conclusions: The robotic implant system was found to have significantly lower angular deviations and insignificantly lower coronal and apical deviations compared to DCAIS. Within the limitations of this review, it can be concluded that robot-assisted implant placement in resin models permits higher accuracy compared to DCAIS and SCAIS systems. However, due to the limited number of comparative studies with high heterogeneity, the findings of this review should be interpreted with caution. Further research is necessary to confirm the clinical application of robotics in implant surgery.

20 November 2022 in Coatings
Verified
Journal Article
Open access
PDF file
MAmohammed alwadei
mohammed alwadei
Mohammed SayedMohammed Sayed
Mohammed Sayed
SJSaurabh Jain
Saurabh Jain
AAAparna Aggarwal
Aparna Aggarwal
HAHatem Al-qarni
Hatem Al-qarni
MGMafaz M. Gharawi
Mafaz M. Gharawi
The aim of this systematic review was to evaluate the marginal fit and internal adaptation of provisional crowns and fixed dental prostheses (FDPs) fabricated using 3D-printing resins and compared them with those fabricated by CAD/CAM (computer-aided designing/computer-aided manufacturing) milling and conventional resins. The null hypotheses tested were that there would be no differences in the marginal fit and internal adaptation of 3D-printed provisional crowns and FDP resins when compared to CAD/CAM-milled and conventional provisional resins. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were used to construct this systematic review. The focused PICO/PECO (Population, Intervention/Exposure, Comparison, Outcome) question was “Do provisional crowns and FDPs (P) fabricated by 3D-printing (I) have similar marginal adaptation and internal fit (O) when compared to those fabricated by CAD/CAM milling and conventional techniques (C)?”. The protocol used for this systematic review was pre-registered in the International Prospective Register of Systematic Reviews (PROSPERO). Electronic databases (e.g., MEDLINE/PubMed and Web of Science (Core Collection)) were systematically searched for indexed English literature published up to June 2022. In the initial electronic search of the selected databases, 519 articles were identified. Duplicates were removed, and screening was performed to select the articles that met the preset inclusion criteria. Sixteen studies were selected for qualitative analysis, but only ten of them provided comparative data and were selected for quantitative analysis. The modified CONSORT scale was used for qualitative analysis, and most of the included studies were rated to be of moderate quality. Based on the findings, it could be concluded that provisional crowns and FDPs fabricated from 3D-printing resins have a superior marginal fit and internal adaptation when compared to CAD/CAM-milled and conventional provisional resins; thus, they can be used as a dependable alternative to other resins.

3 December 2020 in Coatings
Verified
Journal Article
Open access
PDF file
RARana S Al-Hamdan
Rana S Al-Hamdan
BABasil Almutairi
Basil Almutairi
HKHiba F Kattan
Hiba F Kattan
SASaad AlResayes
Saad AlResayes
TATariq Abduljabbar
Tariq Abduljabbar
FVFahim Vohra
Fahim Vohra
Hydroxyapatite (HA) delivery with resin adhesives has potential for re-mineralization of resin–dentin interface. The study prepared an adhesive containing HA and confirmed its presence in adhesive and interaction with the dentin using scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), and Micro-Raman spectroscopy. The aim was to assess the influence of HA incorporation in dentin adhesive on its microtensile bond strength (μ-tbs) and Knoop microhardness (KHN). Thirty teeth each were bonded with CA and HA adhesive using a 10-s smear and photo-polymerized. The specimens in each adhesive group (CA and HA) were divided into sub-groups of 24 h, 8 weeks, and 16 weeks (n = 10) aging durations. μ-tbs was assessed at a crosshead speed of 0.5 mm/minute and bonded interface was analyzed using SEM (n = 20) and Raman spectroscopy (n = 10). Softening of HA adhesive and CA was assessed using KHN. HA adhesive presented higher μ-tbs compared to CA. With an increase in storage time, HA adhesive presented with 100% adhesive failure. Softening was less and KHN was higher for HA adhesive compared to CA (p < 0.05). KHN reduction was higher in CA [19.6 (5.1)%] compared to the HA adhesives [9.7 (4.5)%]. HA adhesive showed superior μTBS and microhardness compared to CA. In the absence of nanoleakage, HA modified adhesive exhibited enhanced bond integrity and better durability of resin dentin bond compared to control adhesive.

28 October 2024 in Medical Science Monitor
Verified
Journal Article
Open access
SJSaurabh Jain
Saurabh Jain
Mohammed SayedMohammed Sayed
Mohammed Sayed
RKReem Abdullah A. Khawaji
Reem Abdullah A. Khawaji
GHGhada Ali J. Hakami
Ghada Ali J. Hakami
ESEman Hassan M. Solan
Eman Hassan M. Solan
KMKhurshid Mattoo
Khurshid Mattoo
Accuracy of 3 Intraoral Scanners in Recording Impressions for Full Arch Dental Implant-Supported Prosthesis: An In Vitro Study - Article abstract #946624

31 October 2023 in Polymers
Verified
Journal Article
Open access
PDF file
HDHarisha Dewan
Harisha Dewan
Mohammed SayedMohammed Sayed
Mohammed Sayed
AJAsayil Jundus
Asayil Jundus
MGMafaz Gharawi
Mafaz Gharawi
SBSafeyah Baeshen
Safeyah Baeshen
AMAlkhansa Moafa
Alkhansa Moafa
The aim of this study was to assess the shear bond strength of 3D-printed and milled provisional restorations using various resin materials and surface finishes. There were 160 preliminary samples in all, and they were split into two groups: the milled group and the 3D-printed group. Based on the resin used for repair (composite or polymethylmethacrylate (PMMA)) and the type of surface treatment utilized (chemical or mechanical), each group was further divided into subgroups. The specimens were subjected to thermocycling from 5 °C to 55 °C for up to 5000 thermal cycles with a dwell time of 30 s. The mechanical qualities of the repaired material underwent testing for shear bond strength (SBS). To identify the significant differences between the groups and subgroups, a statistical analysis was carried out. Three-way ANOVA was used to analyze the effects of each independent component (the material and the bonding condition), as well as the interaction between the independent factors on shear bond strength. Tukey multiple post-hoc tests were used to compare the mean results for each material under various bonding circumstances. The shear bond strengths of the various groups and subgroups differed significantly (p < 0.05). When compared to the milled group, the 3D-printed group had a much greater mean shear bond strength. When compared to PMMA repair, the composite resin material showed a noticeably greater shear bond strength. In terms of surface treatments, the samples with mechanical and chemical surface treatments had stronger shear bonds than those that had not received any. The results of this study demonstrate the effect of the fabrication method, resin type, and surface treatment on the shear bond strength of restored provisional restorations. Particularly when made using composite material and given surface treatments, 3D-printed provisional restorations showed exceptional mechanical qualities. These results can help dentists choose the best fabrication methods, resin materials, and surface treatments through which to increase the durability and bond strength of temporary prosthesis.

24 September 2020 in The Saudi Dental Journal
Verified
Journal Article
Open access
Carlos Alberto JuradoCarlos Alberto Jurado
Carlos Alberto Jurado
SASaad AlResayes
Saad AlResayes
Mohammed SayedMohammed Sayed
Mohammed Sayed
JVJose Villalobos
Jose Villalobos
NLNayely Llanes-Urias
Nayely Llanes-Urias
ATAkimasa Tsujimoto
Akimasa Tsujimoto
Optimal tooth reduction is a key requirement for aesthetics, function, and the longevity of fixed restorations. Research has demonstrated that controlled and conservative tooth preparation is crucial for the long-term success of adhesive restorations. Different techniques of fabricating reduction guides have been previously reported in literature. The present technical note describes the fabrication technique and clinical application of a customized metal preparation reduction guide. Patient presented with tilted maxillary left central incisor. The flared-out part of the tooth was modified prior to veneer restoration preparation. Resin pattern reduction guide was fabricated on the diagnostic cast with a window on the tilted mesial portion of the tooth. After intraoral evaluation, resin pattern guide was casted. Metal reduction guide was place intraorally and reduction was provided on the exposed surface of the tooth. After the removal of the tilted portion, a harmonious arch form allowed the clinician to provide adequate evaluation and preparation for veneer restorations. The device demonstrated good practical value, allowing for selective and controlled reduction of tooth structure, and definitive protection of adjacent tooth surfaces from iatrogenic damage. The clinical outcome successfully addressed the patient’s restorative and aesthetic needs, and the veneer was stable 2 years postoperatively. Use of a metal guide assists clinicians to provide a more predictable reduction of a desired tooth surface, while decreasing the risk of compromising the other/adjacent tooth surfaces.