We describe a simple, non-contact and efficient tool for monitoring the natural activity of a small lizard (Chamaeleo jacksonii) to yield valuable information about their metabolic activity and energy expenditure. It allows monitoring in a non-confined laboratory environment and uses multiple Doppler radars operating at 10.525 GHz. We developed a classification algorithm that can differentiate between fidgeting and locomotion by processing the quadrature baseband signals from the radars. The results have been verified by visual inspection and indicate that the tool could also be used for automated monitoring of the activities of reptiles and other small animals.
The use of a Continuous Wave (CW) quadrature Doppler radar is proposed here for continuous non-invasive Pulse Pressure monitoring. A correspondence between the variation in systemic pulse and variation in the displacement of the chest due to heart is demonstrated, establishing feasibility for the approach. Arctangent demodulation technique was used to process baseband data from radar measurements on two test subjects, in order to determine the absolute cardiac motion. An Omron digital Blood pressure cuff was used to measure the systolic and diastolic blood pressures from which the pulse pressure was calculated. Correlation between pulse pressure and cardiac motion was observed through changes induced due to different postures of the body.
15 July 2013 in IEEE Transactions on Microwave Theory and Techniques
The use of an adaptive noise-cancellation technique has been explored in order to separate multiple sources of motion for a two-frequency Doppler radar system. A 2.45-GHz fundamental Doppler radar system was used together with a harmonic Doppler radar receiver to measure and identify two moving reflectors; one with a harmonic tag and one without. While the tagged motion alone was detected by the harmonic receiver, least mean squares and normalized least mean squares algorithms were applied to the fundamental receiver output to filter out the tagged-related motion content and successfully isolate the information content associated with only the non-tagged motion. Simulations were performed to study the effect of various parameters on the performance of the algorithms, and experiments were conducted to validate the feasibility of the method.
A harmonic tag was designed and fabricated to show the feasibility of sensing cardiopulmonary related Doppler shift in the received second harmonic signal. A fundamental frequency of 2.45 GHz was transmitted at a target and a quadrature homodyne receiver used to sense the received signal from a tag on the target. The setup was used to successfully isolate periodic motion from a tag on a programmable mechanical target and to sense respiratory motion of a human subject, even when the targets were in close proximity to other moving objects.
A design for a physiological radar monitoring system (PRMS) that can be integrated with clinical sleep monitoring systems is presented. The PRMS uses two radar systems at 2.45GHz and 24 GHz to achieve both high sensitivity and high resolution. The system can acquire data, perform digital processing and output appropriate conventional analog outputs with a latency of 130 ms, which can be recorded and displayed by a gold standard sleep monitoring system, along with other standard sensor measurements.