Ehsan Yavari

Dr. Ehsan Yavari


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2011 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Verified
Conference Paper
Closed access
EYEhsan Yavari
Ehsan Yavari
CSChenyan Song
Chenyan Song
VLVictor Lubecke
Victor Lubecke
OBOlga Boric-Lubecke
Olga Boric-Lubecke
System-on-Chip (SoC) based Doppler radar occupancy sensor is developed through non contact detection of respiratory signals. The radio was developed using off the shelf low power RF CC2530 SoC chip by Texas Instruments. In order to save power, the transmitter sends signal intermittently at 2.405 GHz. Reflected pulses are demodulated, and the baseband signals are processed to recover periodic motion. The system was tested both with mechanical target and a human subject. In both cases Doppler radar detected periodic motion closely matched the actual motion, and it has been shown that an SoC based system can be used for subject detection.

1 July 2013
Verified
Conference Paper
Closed access
ASAditya Singh
Aditya Singh
MBMehran Baboli
Mehran Baboli
XGXiaomeng Gao
Xiaomeng Gao
EYEhsan Yavari
Ehsan Yavari
BPBryson Padasdao
Bryson Padasdao
VLVictor Manuel Lubecke
Victor Manuel Lubecke
A design for a physiological radar monitoring system (PRMS) that can be integrated with clinical sleep monitoring systems is presented. The PRMS uses two radar systems at 2.45GHz and 24 GHz to achieve both high sensitivity and high resolution. The system can acquire data, perform digital processing and output appropriate conventional analog outputs with a latency of 130 ms, which can be recorded and displayed by a gold standard sleep monitoring system, along with other standard sensor measurements.

8 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MSMd Sakib Galib Sourav
Md Sakib Galib Sourav
EYEhsan Yavari
Ehsan Yavari
XGXiaomeng Gao
Xiaomeng Gao
AMArthur Maskrey
Arthur Maskrey
YZYao Zheng
Yao Zheng
OBOlga Boric-Lubecke
Olga Boric-Lubecke
Building occupancy information is significant for a variety of reasons, from allocation of resources in smart buildings to responding during emergency situations. As most people spend more than 90% of their time indoors, a comfortable indoor environment is crucial. To ensure comfort, traditional HVAC systems condition rooms assuming maximum occupancy, accounting for more than 50% of buildings’ energy budgets in the US. Occupancy level is a key factor in ensuring energy efficiency, as occupancy-controlled HVAC systems can reduce energy waste by conditioning rooms based on actual usage. Numerous studies have focused on developing occupancy estimation models leveraging existing sensors, with camera-based methods gaining popularity due to their high precision and widespread availability. However, the main concern with using cameras for occupancy estimation is the potential violation of occupants’ privacy. Unlike previous video-/image-based occupancy estimation methods, we addressed the issue of occupants’ privacy in this work by proposing and investigating both motion-based and motion-independent occupancy counting methods on intentionally blurred video frames. Our proposed approach included the development of a motion-based technique that inherently preserves privacy, as well as motion-independent techniques such as detection-based and density-estimation-based methods. To improve the accuracy of the motion-independent approaches, we utilized deblurring methods: an iterative statistical technique and a deep-learning-based method. Furthermore, we conducted an analysis of the privacy implications of our motion-independent occupancy counting system by comparing the original, blurred, and deblurred frames using different image quality assessment metrics. This analysis provided insights into the trade-off between occupancy estimation accuracy and the preservation of occupants’ visual privacy. The combination of iterative statistical deblurring and density estimation achieved a 16.29% counting error, outperforming our other proposed approaches while preserving occupants’ visual privacy to a certain extent. Our multifaceted approach aims to contribute to the field of occupancy estimation by proposing a solution that seeks to balance the trade-off between accuracy and privacy. While further research is needed to fully address this complex issue, our work provides insights and a step towards a more privacy-aware occupancy estimation system.

1 August 2012 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Verified
Conference Paper
Closed access
ESEhsaneh Shahhaidar
Ehsaneh Shahhaidar
EYEhsan Yavari
Ehsan Yavari
JYJared Young
Jared Young
OBOlga Boric-Lubecke
Olga Boric-Lubecke
CSCris Stickley
Cris Stickley
Human respiratory effort can be harvested to power wearable biosensors and mobile electronic devices. The very first step toward designing a harvester is to estimate available energy and power. This paper describes an estimation of the available power and energy due to the movements of the torso during breathing, using Doppler radar by detecting breathing rate, torso displacement, torso movement velocity and acceleration along the sagittal movement of the torso. The accuracy of the detected variables is verified by two reference methods. The experimental result obtained from a healthy female human subject shows that the available power from circumferential movement can be higher than the power from the sagittal movement.