Victor Manuel Lubecke

Prof. Victor Manuel Lubecke

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MBMehran Baboli
Mehran Baboli
ASAditya Singh
Aditya Singh
BSBruce Soll
Bruce Soll
OBOlga Boric-Lubecke
Olga Boric-Lubecke
VLVictor Manuel Lubecke
Victor Manuel Lubecke
A non-contact and non-invasive physiological radar monitoring system (PRMS) is introduced. The system is based on motion detection using quadrature microwave Doppler radar, eliminating the need to place sensors on the body. An algorithm was designed to perform real-time actigraphy and sleep apnea detection. The system was validated with clinical polysomnography(PSG) in a sleep study facility on ten consented volunteers with known obstructive sleep apnea. Data obtained from both PRMS and clinical PSG systems were rated by a sleep technician and show an excellent agreement in the detected apnea and hypopnea events. The apnea-hypopnea events were distinguished with an overall sensitivity of 86%, the specificity of 91% and accuracy of 92%.

22 March 2018 in IEEE Journal on Emerging and Selected Topics in Circuits and Systems
Verified
Journal Article
Closed access
ARAshikur Rahman
Ashikur Rahman
VLVictor Manuel Lubecke
Victor Manuel Lubecke
OBOlga Boric-Lubecke
Olga Boric-Lubecke
JPJan H. Prins
Jan H. Prins
TSTakuya Sakamoto
Takuya Sakamoto
A low distortion dc coupled CW radar system with high signal to noise ratio is capable of accurate representation of respiration in human subjects. We propose to test the hypothesis that a non-contact physiological radar monitoring system which measures and characterizes subtle body kinematics, can be made to resolve patterns accurately enough to recognize an individual's identity. This paper investigates a technique to attain the requisite signal to noise ratio by dc offset management. Detailed exploration of the unique features in respiration signals using noncontact CW Doppler radar are presented. A proposed dynamic segmentation technique allowed detection of various unique features and patterns. KMN nearest neighbor and majority vote algorithms were implemented in software for this radar-based unique identification system. The system was tested and validated for six test subjects with 95% success rate. Fractal analysis of minor components of linearly demodulated radar signal was also presented for additional improvement in accuracy. This paper is believed to be significant as radar unique identification of human subjects has many potential applications, including security, health monitoring, IoT applications, and virtual reality.

11 January 2021 in IEEE Journal of Microwaves
Verified
Journal Article
Open access
Changzhi LiChangzhi Li
Changzhi Li
VLVictor Manuel Lubecke
Victor Manuel Lubecke
OBOlga Boric-Lubecke
Olga Boric-Lubecke
Jenshan LinJenshan Lin
Jenshan Lin
Modern microwave radar technologies and systems are taking important roles in healthcare, security, and human-machine interface by remote sensing of human life activities. This paper first reviews the developments in the past decade on the sensing front-end, transponder tag, and leveraging of other wireless infrastructure such as Wi-Fi. Based on the state-of-the-art engineering technologies, several emerging applications will then be studied, including continuous authentication, behavior recognition, human-aware localization, occupancy sensing, blood pressure monitoring, and sleep medicine. As radio frequency spectrum becomes a scarce resource, the allocation and spectrum sharing of life activity sensing bandwidth with other wireless infrastructures will be discussed. Several future research directions will be laid out to solve challenges for ubiquitous deployment of these sensing technologies at the human-microwave frontier.

15 July 2020 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Shekh Md Mahmudul IslamShekh Md Mahmudul Islam
Shekh Md Mahmudul Islam
OBOlga Boric-Lubecke
Olga Boric-Lubecke
YZYao Zheng
Yao Zheng
VLVictor Manuel Lubecke
Victor Manuel Lubecke
Non-contact vital signs monitoring using microwave Doppler radar has shown great promise in healthcare applications. Recently, this unobtrusive form of physiological sensing has also been gaining attention for its potential for continuous identity authentication, which can reduce the vulnerability of traditional one-pass validation authentication systems. Physiological Doppler radar is an attractive approach for continuous identity authentication as it requires neither contact nor line-of-sight and does not give rise to privacy concerns associated with video imaging. This paper presents a review of recent advances in radar-based identity authentication systems. It includes an evaluation of the applicability of different research efforts in authentication using respiratory patterns and heart-based dynamics. It also identifies aspects of future research required to address remaining challenges in applying unobtrusive respiration-based or heart-based identity authentication to practical systems. With the advancement of machine learning and artificial intelligence, radar-based continuous authentication can grow to serve a wide range of valuable functions in society.

21 August 2018 in IEEE Sensors Letters
Verified
Journal Article
Open access
TSTakuya Sakamoto
Takuya Sakamoto
XGXiaomeng Gao
Xiaomeng Gao
EYEhsan Yavari
Ehsan Yavari
ARAshikur Rahman
Ashikur Rahman
OBOlga Boric-Lubecke
Olga Boric-Lubecke
VLVictor Manuel Lubecke
Victor Manuel Lubecke
We propose a hand gesture recognition technique using a convolutional neural network applied to radar echo inphase/quadrature (I/Q) plot trajectories. The proposed technique is demonstrated to accurately recognize six types of hand gestures for ten participants. The system consists of a low-cost 2.4-GHz continuous-wave monostatic radar with a single antenna. The radar echo trajectories are converted to low-resolution images and are used for the training and evaluation of the proposed technique. Results indicate that the proposed technique can recognize hand gestures with average accuracy exceeding 90%.

1 January 2008
Verified
Book Chapter
Closed access
PDF file
AHAnders Høst-Madsen
Anders Høst-Madsen
NPNicolas Petrochilos
Nicolas Petrochilos
OBOlga Boric-Lubecke
Olga Boric-Lubecke
VLVictor Manuel Lubecke
Victor Manuel Lubecke
BPByung-Kwon Park
Byung-Kwon Park
QZQin Zhou
Qin Zhou