Ulf Stolzenberg

Dr. Ulf Stolzenberg

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 November 2021 in Materials
Verified
Journal Article
Open access
PDF file
USUlf Stolzenberg
Ulf Stolzenberg
Mayka Schmitt RahnerMayka Schmitt Rahner
Mayka Schmitt Rahner
BPBjörn Pullner
Björn Pullner
HLHerbert Legall
Herbert Legall
Jörn BonseJörn Bonse
Jörn Bonse
Jörg KrügerJörg Krüger
Jörg Krüger
Interactions between ultrashort laser pulses with intensities larger than 1013 W/cm2 and solids during material processing can lead to the emission of X-rays with photon energies above 5 keV, causing radiation hazards to operators. A framework for inspecting X-ray emission hazards during laser material processing has yet to be developed. One requirement for conducting radiation protection inspections is using a reference scenario, i.e., laser settings and process parameters that will lead to an almost constant and high level of X-ray emissions. To study the feasibility of setting up a reference scenario in practice, ambient dose rates and photon energies were measured using traceable measurement equipment in an industrial setting at SCHOTT AG. Ultrashort pulsed (USP) lasers with a maximum average power of 220 W provided the opportunity to measure X-ray emissions at laser peak intensities of up to 3.3 × 1015 W/cm2 at pulse durations of ~1 ps. The results indicate that increasing the laser peak intensity is insufficient to generate high dose rates. The investigations were affected by various constraints which prevented measuring high ambient dose rates. In this work, a list of issues which may be encountered when performing measurements at USP-laser machines in industrial settings is identified.

16 December 2022 in Materials
Verified
Journal Article
Open access
PDF file
KBKatrin Böttcher
Katrin Böttcher
Mayka Schmitt RahnerMayka Schmitt Rahner
Mayka Schmitt Rahner
USUlf Stolzenberg
Ulf Stolzenberg
SKSebastian Kraft
Sebastian Kraft
Jörn BonseJörn Bonse
Jörn Bonse
Jörg KrügerJörg Krüger
Jörg Krüger
Ultrashort pulse laser processing can result in the secondary generation of unwanted X-rays if a critical laser irradiance of about 1013 W cm−2 is exceeded. Spectral X-ray emissions were investigated during the processing of tungsten and steel using three complementary spectrometers (based on CdTe and silicon drift detectors) simultaneously for the identification of a worst-case spectral scenario. Therefore, maximum X-ray photon energies were determined, and corresponding dose equivalent rates were calculated. An ultrashort pulse laser workstation with a pulse duration of 274 fs, a center wavelength of 1030 nm, pulse repetition rates between 50 kHz and 200 kHz, and a Gaussian laser beam focused to a spot diameter of 33 μm was employed in a single pulse and burst laser operation mode. Different combinations of laser pulse energy and repetition rate were utilized, keeping the average laser power constant close to the maximum power of 20 W. Peak irradiances I0 ranging from 7.3 × 1013 W cm−2 up to 3.0 × 1014 W cm−2 were used. The X-ray dose equivalent rate increases for lower repetition rates and higher pulse energy if a constant average power is used. Laser processing with burst mode significantly increases the dose rates and the X-ray photon energies. A maximum X-ray photon energy of about 40 keV was observed for burst mode processing of tungsten with a repetition rate of 50 kHz and a peak irradiance of 3 × 1014 W cm−2.

13 November 2026 in Measurement
Verified
Journal Article
Open access
Daniel RábagoDaniel Rábago
Daniel Rábago
SCScott Chambers
Scott Chambers
MGMaksym Gachkivskyi
Maksym Gachkivskyi
RCRoger Curcoll
Roger Curcoll
MFMarta Fuente
Marta Fuente
Claudia GrossiClaudia Grossi
Claudia Grossi