8 April 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JKJon-Émile S. Stuart Kenny
Jon-Émile S. Stuart Kenny
CMChelsea Munding
Chelsea Munding
JEJoseph K. Eibl
Joseph K. Eibl
AEAndrew M. Eibl
Andrew M. Eibl
BLBradley F. Long
Bradley F. Long
CDChristine E. M. Demore
Christine E. M. Demore
Quantitative Doppler ultrasound of the carotid artery has been proposed as an instantaneous surrogate for monitoring rapid changes in left ventricular output. Tracking immediate changes in the arterial Doppler spectrogram has value in acute care settings such as the emergency department, operating room and critical care units. We report a novel, hands-free, continuous-wave Doppler ultrasound patch that adheres to the neck and tracks Doppler blood flow metrics in the common carotid artery using an automated algorithm. String and blood-mimicking test objects demonstrated that changes in velocity were accurately measured using both manually and automatically traced Doppler velocity waveforms. In a small usability study with 22 volunteer users (17 clinical, 5 lay), all users were able to locate the carotid Doppler signal on a volunteer subject, and, in a subsequent survey, agreed that the device was easy to use. To illustrate potential clinical applications of the device, the Doppler ultrasound patch was used on a healthy volunteer undergoing a passive leg raise (PLR) as well as on a congestive heart failure patient at resting baseline. The wearable carotid Doppler patch holds promise because of its ease-of-use, velocity measurement accuracy, and ability to continuously record Doppler spectrograms over many cardiac and respiratory cycles.

1 May 2021 in Journal of Cardiothoracic and Vascular Anesthesia
Verified
Journal Article
Open access
PDF file
JKJon-Émile S. Stuart Kenny
Jon-Émile S. Stuart Kenny
In this Emerging Technology Review, a novel, wireless, wearable Doppler ultrasound patch is described as a tool for resuscitation. The device is designed, foremost, as a functional hemodynamic monitor—a simple, fast, and consistent method for measuring hemodynamic change with preload variation. More generally, functional hemodynamic monitoring is a paradigm that helps predict stroke volume response to additional intravenous volume. Because Doppler ultrasound of the left ventricular outflow tract noninvasively measures stroke volume in realtime, it increasingly is deployed for this purpose. Nevertheless, Doppler ultrasound in this manner is cumbersome, especially when repeat assessments are needed. Accordingly, peripheral arteries have been studied and various measures from the common carotid artery Doppler signal act as windows to the left ventricle. Yet, handheld Doppler ultrasound of a peripheral artery is susceptible to human measurement error and statistical limitations from inadequate beat sample size. Therefore, a wearable Doppler ultrasound capable of continuous assessment minimizes measurement inconsistencies and smooths inherent physiologic variation by sampling many more cardiac cycles. Reaffirming clinical studies, the ultrasound patch tracks immediate SV change with excellent accuracy in healthy volunteers when cardiac preload is altered by various maneuvers. The wearable ultrasound also follows jugular venous Doppler, which qualitatively trends right atrial pressure. With further clinical research and the application of artificial intelligence, the monitoring modalities with this new technology are manifold.

1 August 2021 in British Journal of Anaesthesia
Verified
Journal Article
Closed access
JKJon-Émile S. Stuart Kenny
Jon-Émile S. Stuart Kenny
IBIgor Barjaktarevic
Igor Barjaktarevic
DMDavid C. Mackenzie
David C. Mackenzie
MEMai Elfarnawany
Mai Elfarnawany
ZYZhen Yang
Zhen Yang
BJBruce D. Johnson
Bruce D. Johnson

17 September 2020 in Intensive Care Medicine Experimental
Verified
Journal Article
Open access
PDF file
JKJon-Émile S. Stuart Kenny
Jon-Émile S. Stuart Kenny
IBIgor Barjaktarevic
Igor Barjaktarevic
DMDavid C. Mackenzie
David C. Mackenzie
AEAndrew M. Eibl
Andrew M. Eibl
MPMatthew Parrotta
Matthew Parrotta
JEJoseph K. Eibl
Joseph K. Eibl
Background: Change of the corrected flow time (Ftc) is a surrogate for tracking stroke volume (SV) in the intensive care unit. Multiple Ftc equations have been proposed; many have not had their diagnostic characteristics for detecting SV change reported. Further, little is known about the inherent Ftc variability induced by the respiratory cycle.Materials and methods: Using a wearable Doppler ultrasound patch, we studied the clinical performance of 11 Ftc equations to detect a 10% change in SV measured by non-invasive pulse contour analysis; 26 healthy volunteers performed a standardized cardiac preload modifying maneuver.Results: One hundred changes in cardiac preload and 3890 carotid beats were analyzed. Most of the 11 Ftc equations studied had similar diagnostic attributes. Wodeys’ and Chambers’ formulae had identical results; a 2% change in Ftc detected a 10% change in SV with a sensitivity and specificity of 96% and 93%, respectively. Similarly, a 3% change in Ftc calculated by Bazett’s formula displayed a sensitivity and specificity of 91% and 93%. FtcWodeyhad 100% concordance and anR2of 0.75 with change in SV; these values were 99%, 0.76 and 98%, 0.71 for FtcChambersand FtcBazetts, respectively. As an exploratory analysis, we studied 3335 carotid beats for the dispersion of Ftc during quiet breathing using the equations of Wodey and Bazett. The coefficient of variation of Ftc during quiet breathing for these formulae were 0.06 and 0.07, respectively.Conclusions: Most of the 11 different equations used to calculate carotid artery Ftc from a wearable Doppler ultrasound patch had similar thresholds and abilities to detect SV change in healthy volunteers. Variation in Ftc induced by the respiratory cycle is important; measuring a clinically significant change in Ftc with statistical confidence requires a large sample of beats.

4 August 2020 in Journal of Ultrasound in Medicine
Verified
Journal Article
Closed access
PDF file
IBIgor Barjaktarevic
Igor Barjaktarevic
JKJon-Émile S. Stuart Kenny
Jon-Émile S. Stuart Kenny
DBDavid Berlin
David Berlin
MCMaxime Cannesson
Maxime Cannesson

9 February 2022 in Medical Sciences
Verified
Journal Article
Open access
PDF file
JKJon-Émile S. Stuart Kenny
Jon-Émile S. Stuart Kenny
Ultrasonography is becoming the favored hemodynamic monitoring utensil of emergentologists, anesthesiologists and intensivists. While the roles of ultrasound grow and evolve, many clinical applications of ultrasound stem from qualitative, image-based protocols, especially for diagnosing and managing circulatory failure. Often, these algorithms imply or suggest treatment. For example, intravenous fluids are opted for or against based upon ultrasonographic signs of preload and estimation of the left ventricular ejection fraction. Though appealing, image-based algorithms skirt some foundational tenets of cardiac physiology; namely, (1) the relationship between cardiac filling and stroke volume varies considerably in the critically ill, (2) the correlation between cardiac filling and total vascular volume is poor and (3) the ejection fraction is not purely an appraisal of cardiac function but rather a measure of coupling between the ventricle and the arterial load. Therefore, management decisions could be enhanced by quantitative approaches, enabled by Doppler ultrasonography. Both fluid ‘responsiveness’ and ‘tolerance’ are evaluated by Doppler ultrasound, but the physiological relationship between these constructs is nebulous. Accordingly, it is argued that the link between them is founded upon the Frank–Starling–Sarnoff relationship and that this framework helps direct future ultrasound protocols, explains seemingly discordant findings and steers new routes of enquiry.