Christine E. M. Demore

Dr. Christine E. M. Demore

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JKJon-Émile S. Stuart Kenny
Jon-Émile S. Stuart Kenny
CMChelsea Munding
Chelsea Munding
JEJoseph K. Eibl
Joseph K. Eibl
AEAndrew M. Eibl
Andrew M. Eibl
BLBradley F. Long
Bradley F. Long
CDChristine E. M. Demore
Christine E. M. Demore
Quantitative Doppler ultrasound of the carotid artery has been proposed as an instantaneous surrogate for monitoring rapid changes in left ventricular output. Tracking immediate changes in the arterial Doppler spectrogram has value in acute care settings such as the emergency department, operating room and critical care units. We report a novel, hands-free, continuous-wave Doppler ultrasound patch that adheres to the neck and tracks Doppler blood flow metrics in the common carotid artery using an automated algorithm. String and blood-mimicking test objects demonstrated that changes in velocity were accurately measured using both manually and automatically traced Doppler velocity waveforms. In a small usability study with 22 volunteer users (17 clinical, 5 lay), all users were able to locate the carotid Doppler signal on a volunteer subject, and, in a subsequent survey, agreed that the device was easy to use. To illustrate potential clinical applications of the device, the Doppler ultrasound patch was used on a healthy volunteer undergoing a passive leg raise (PLR) as well as on a congestive heart failure patient at resting baseline. The wearable carotid Doppler patch holds promise because of its ease-of-use, velocity measurement accuracy, and ability to continuously record Doppler spectrograms over many cardiac and respiratory cycles.

1 February 2020 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
JYJudy Yan
Judy Yan
MYMelissa Yin
Melissa Yin
FFF. Stuart Foster
F. Stuart Foster
CDChristine E. M. Demore
Christine E. M. Demore

8 July 2019 in Molecular Imaging and Biology
Verified
Journal Article
Open access
PDF file
JFJohann Le Floc’h
Johann Le Floc’h
HLHoang D. Lu
Hoang D. Lu
Tristan LimTristan Lim
Tristan Lim
CDChristine E. M. Demore
Christine E. M. Demore
RPRobert K. Prud'homme
Robert K. Prud'homme
FFF. Stuart Foster
F. Stuart Foster
Purpose Blood-brain barrier disruption (BBBD) is of interest for treating neurodegenerative diseases and tumors by enhancing drug delivery. Focused ultrasound (FUS) is a powerful method to alleviate BBB challenges; however, the detection of BBB opening by non-invasive methods remains limited. The purpose of this work is to demonstrate that 3D transcranial color Doppler (3DCD) and photoacoustic imaging (PAI) combined with custom-made nanoparticle (NP)-mediated FUS delivery can detect BBBD in mice. Procedures We use MRI and stereotactic ultrasound-mediated BBBD to create and confirm four openings in the left hemisphere and inject intravenously indocyanine green (ICG) and three sizes (40 nm, 100 nm, and 240 nm in diameter) of fluorophore-labeled NPs. We use PAI and fluorescent imaging (FI) to assess the spatial distribution of ICG/NPs in tissues. Results A reversible 41 ± 12 % (n = 8) decrease in diameter of the left posterior cerebral artery (PCA) relative to the right after FUS treatment is found using CD images. The spectral unmixing of photoacoustic images of the in vivo (2 h post FUS), perfused, and ex vivo brain reveals a consistent distribution pattern of ICG and NPs at *FUS locations. Ex vivo spectrally unmixed photoacoustic images show that the opening width is, on average, 1.18 ± 0.12 mm and spread laterally 0.49 ± 0.05 mm which correlated well with the BBB opening locations on MR images. In vivo PAI confirms a deposit of NPs in tissues for hours and potentially days, is less sensitive to NPs of lower absorbance at a depth greater than 3 mm and too noisy with NPs above an absorbance of 85.4. FI correlates well with ex vivo PAI to a depth of 3 mm in tissues for small NPs and 4.74 mm for large NPs. Conclusions 3DCD can monitor BBBD over time by detecting reversible anatomical changes in the PCA. In vivo 3DPAI at 15 MHz combined with circulating ICG and/or NPs with suitable properties can assess BBB opening 2 h post FUS.

29 June 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
JYJing Yang
Jing Yang
ECEmmanuel Cherin
Emmanuel Cherin
JYJianhua Yin
Jianhua Yin
INIsabel G. Newsome
Isabel G. Newsome
TKThomas M. Kierski
Thomas M. Kierski
CDChristine E. M. Demore
Christine E. M. Demore
Superharmonic imaging with dual-frequency imaging systems uses conventional low-frequency ultrasound transducers on transmit, and high-frequency transducers on receive to detect higher order harmonic signals from microbubble contrast agents, enabling high-contrast imaging while suppressing clutter from background tissues. Current dual-frequency imaging systems for superharmonic imaging have been used for visualizing tumor microvasculature, with single-element transducers for each of the low- and high-frequency components. However, the useful field of view is limited by the fixed focus of single-element transducers, while image frame rates are limited by the mechanical translation of the transducers. In this article, we introduce an array-based dual-frequency transducer, with low-frequency and high-frequency arrays integrated within the probe head, to overcome the limitations of single-channel dual-frequency probes. The purpose of this study is to evaluate the line-by-line high-frequency imaging and superharmonic imaging capabilities of the array-based dual-frequency probe for acoustic angiography applications in vitro and in vivo. We report center frequencies of 1.86 MHz and 20.3 MHz with -6 dB bandwidths of 1.2 MHz (1.2-2.4 MHz) and 14.5 MHz (13.3-27.8 MHz) for the low- and high-frequency arrays, respectively. With the proposed beamforming schemes, excitation pressure was found to range from 336 to 458 kPa at its azimuthal foci. This was sufficient to induce nonlinear scattering from microbubble contrast agents. Specifically, in vitro contrast channel phantom imaging and in vivo xenograft mouse tumor imaging by this probe with superharmonic imaging showed contrast-to-tissue ratio improvements of 17.7 and 16.2 dB, respectively, compared to line-by-line micro-ultrasound B-mode imaging.

12 December 2022 in Acta Biomaterialia
Verified
Journal Article
Closed access
JSJoseph A. Sebastian
Joseph A. Sebastian
ESEric M. Strohm
Eric M. Strohm
ECEmmanuel Cherin
Emmanuel Cherin
BMBahram Mirani
Bahram Mirani
CDChristine E. M. Demore
Christine E. M. Demore
CSCraig A. Simmons
Craig A. Simmons

1 September 2015 in Ultrasonics
Verified
Journal Article
Open access
YQYongqiang Qiu
Yongqiang Qiu
HWHan Wang
Han Wang
SGSylvia E. Gebhardt
Sylvia E. Gebhardt
ABAleksandrs Bolhovitins
Aleksandrs Bolhovitins
CDChristine E. M. Demore
Christine E. M. Demore
SCSandy Cochran
Sandy Cochran
This paper reports the development of a two-dimensional thick film lead zirconate titanate (PZT) ultrasonic transducer array, operating at frequency approximately 7.5MHz, to demonstrate the potential of this fabrication technique for microparticle manipulation. All layers of the array are screen-printed then sintered on an alumina substrate without any subsequent patterning processes. The thickness of the thick film PZT is 139±2μm, the element pitch of the array is 2.3mm, and the dimension of each individual PZT element is 2×2mm(2) with top electrode 1.7×1.7mm(2). The measured relative dielectric constant of the PZT is 2250±100 and the dielectric loss is 0.09±0.005 at 10kHz. Finite element analysis was used to predict the behaviour of the array and to optimise its configuration. Electrical impedance spectroscopy and laser vibrometry were used to characterise the array experimentally. The measured surface motion of a single element is on the order of tens of nanometres with a 10Vpeak continuous sinusoidal excitation. Particle manipulation experiments have been demonstrated with the array by manipulating Ø10μm polystyrene microspheres in degassed water. The simplified array fabrication process and the bulk production capability of screen-printing suggest potential for the commercialisation of multilayer planar resonant devices for ultrasonic particle manipulation.