Quantitative Doppler ultrasound of the carotid artery has been proposed as an instantaneous surrogate for monitoring rapid changes in left ventricular output. Tracking immediate changes in the arterial Doppler spectrogram has value in acute care settings such as the emergency department, operating room and critical care units. We report a novel, hands-free, continuous-wave Doppler ultrasound patch that adheres to the neck and tracks Doppler blood flow metrics in the common carotid artery using an automated algorithm. String and blood-mimicking test objects demonstrated that changes in velocity were accurately measured using both manually and automatically traced Doppler velocity waveforms. In a small usability study with 22 volunteer users (17 clinical, 5 lay), all users were able to locate the carotid Doppler signal on a volunteer subject, and, in a subsequent survey, agreed that the device was easy to use. To illustrate potential clinical applications of the device, the Doppler ultrasound patch was used on a healthy volunteer undergoing a passive leg raise (PLR) as well as on a congestive heart failure patient at resting baseline. The wearable carotid Doppler patch holds promise because of its ease-of-use, velocity measurement accuracy, and ability to continuously record Doppler spectrograms over many cardiac and respiratory cycles.
OBJECTIVE: Measuring fluid responsiveness is important in the management of critically ill patients, with a 10–15% change in cardiac output typically being used to indicate “fluid responsiveness.” Ideally, these changes would be measured noninvasively and peripherally. The aim of this study was to determine how the common carotid artery (CCA) maximum velocity changes with total circulatory flow when confounding factors are mitigated and determine a value for CCA maximum velocity corresponding to a 10% change in total circulatory flow. DESIGN: Prospective observational pilot study. SETTING: Patients undergoing elective, on-pump coronary artery bypass grafting (CABG) surgery. PATIENTS: Fourteen patients were referred for elective coronary artery bypass grafting surgery. INTERVENTIONS: Cardiopulmonary bypass (CPB) pump flow changes during surgery, as chosen by the perfusionist. MEASUREMENTS: A hands-free, wearable Doppler patch was used for CCA velocity measurements with the aim of preventing user errors in ultrasound measurements. Maximum CCA velocity was determined from the spectrogram acquired by the Doppler patch. CPB flow rates were recorded as displayed on the CPB console, and further measured from the peristaltic pulsation frequency visible on the recorded Doppler spectrograms. MAIN RESULTS: Changes in CCA maximum velocity tracked well with changes in CPB flow. On average, a 13.6% change in CCA maximum velocity was found to correspond to a 10% change in CPB flow rate. CONCLUSIONS: Changes in CCA velocity may be a useful surrogate for determining fluid responsiveness when user error can be mitigated.
(1) Background: The inspiratory collapse of the inferior vena cava (IVC), a non-invasive surrogate for right atrial pressure, is often used to predict whether a patient will augment stroke volume (SV) in response to a preload challenge. There is a correlation between changing stroke volume (SV∆) and corrected flow time of the common carotid artery (ccFT∆). (2) Objective: We studied the relationship between IVC collapsibility and ccFT∆ in healthy volunteers during preload challenges. (3) Methods: A prospective, observational, pilot study in euvolemic, healthy volunteers with no cardiovascular history was undertaken in a local physiology lab. Using a tilt-table, we studied two degrees of preload augmentation from (a) supine to 30-degrees head-down and (b) fully-upright to 30-degrees head down. In the supine position, % of IVC collapse with respiration, sphericity index and portal vein pulsatility was calculated. The common carotid artery Doppler pulse was continuously captured using a wireless, wearable ultrasound system. (4) Results: Fourteen subjects were included. IVC % collapse with respiration ranged between 10% and 84% across all subjects. Preload responsiveness was defined as an increase in ccFT∆ of at least 7 milliseconds. A total of 79% (supine baseline) and 100% (head-up baseline) of subjects were preload-responsive. No supine venous measures (including IVC % collapse) were significantly related to ccFT∆. (5) Conclusions: From head-up baseline, 100% of healthy subjects were ‘preload-responsive’ as per the ccFT∆. Based on the 42% and 25% IVC collapse thresholds in the supine position, only 50% and 71% would have been labeled ‘preload-responsive’.
A wireless, wearable Doppler ultrasound offers a new paradigm for linking physiology to resuscitation medicine. To this end, the image analysis of simultaneously-acquired venous and arterial Doppler spectrograms attained by wearable ultrasound represents a new source of hemodynamic data. Previous investigators have reported a direct relationship between the central venous pressure (CVP) and the ratio of the internal jugular-to-common carotid artery diameters. Because Doppler power is directly related to the number of red cell scatterers within a vessel, we hypothesized that (1) the ratio of internal jugular-to-carotid artery Doppler power (V/APOWER) would be a surrogate for the ratio of the vascular areas of these two vessels and (2) the V/APOWER would track the anticipated CVP change during simulated hemorrhage and resuscitation. To illustrate this proof-of-principle, we compared the change in V/APOWER obtained via a wireless, wearable Doppler ultrasound to B-mode ultrasound images during a head-down tilt. Additionally, we elucidated the change in the V/APOWER during simulated hemorrhage and transfusion via lower body negative pressure (LBNP) and release. With these Interesting Images, we show that the Doppler V/APOWER ratio qualitatively tracks anticipated changes in CVP (e.g., cardiac preload) which is promising for both diagnosis and management of hemodynamic unrest.