Julien Sarrazin

Dr. Julien Sarrazin


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2009 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
JSJulien Sarrazin
Julien Sarrazin
YMYann Mahe
Yann Mahe
SAStéphane Avrillon
Stéphane Avrillon
STSerge Toutain
Serge Toutain
A new single-feed reconfigurable antenna for pattern diversity is presented in this paper. The proposed structure is based on a metallic cubic cavity which radiates through rectangular slots. The pattern reconfiguration is achieved with PIN diode switches by short-circuiting slots in their center. The designed antenna can switch between three different radiation patterns which radiate in a 4pi steradian range and can receive any incident field polarizations. A prototype of the antenna, including PIN diodes and operating in the 5 GHz band, has been built to demonstrate the feasibility of the concept. Measurements have been conducted and three-dimensional radiation patterns are provided. Diversity performances are evaluated by calculating the envelope correlation coefficient.

15 November 2016 in Sensors
Verified
Journal Article
Open access
PDF file
HTHalim Tannous
Halim Tannous
Dan IstrateDan Istrate
Dan Istrate
ABAziz Benlarbi-Delaï
Aziz Benlarbi-Delaï
JSJulien Sarrazin
Julien Sarrazin
DGDidier Gamet
Didier Gamet
TDTien Tuan Dao
Tien Tuan Dao
Exergames have been proposed as a potential tool to improve the current practice of musculoskeletal rehabilitation. Inertial or optical motion capture sensors are commonly used to track the subject’s movements. However, the use of these motion capture tools suffers from the lack of accuracy in estimating joint angles, which could lead to wrong data interpretation. In this study, we proposed a real time quaternion-based fusion scheme, based on the extended Kalman filter, between inertial and visual motion capture sensors, to improve the estimation accuracy of joint angles. The fusion outcome was compared to angles measured using a goniometer. The fusion output shows a better estimation, when compared to inertial measurement units and Kinect outputs. We noted a smaller error (3.96°) compared to the one obtained using inertial sensors (5.04°). The proposed multi-sensor fusion system is therefore accurate enough to be applied, in future works, to our serious game for musculoskeletal rehabilitation.

28 February 2012 in IEEE Antennas and Wireless Propagation Letters
Verified
Journal Article
Closed access
JSJulien Sarrazin
Julien Sarrazin
ALAnne-Claire Lepage
Anne-Claire Lepage
Xavier BegaudXavier Begaud
Xavier Begaud
In this letter, characterization of circular high-impedance surfaces (HISs) is investigated. The reflection phase characterization used for rectangular HISs is here extended to circular lattices. Circular HISs discussed in this letter present a 2-D periodicity, and consequently the phase diagram is determined for concentric and radial polarizations. The effect of mapping a rectangular HIS into a circular one is investigated in order to give some insights regarding the design of such metasurface. The presented characterization constitutes a useful tool for the design of low-profile antennas using HIS as reflector.

12 November 2019 in IEEE Microwave and Wireless Components Letters
Verified
Journal Article
Closed access
SWSiqi Wang
Siqi Wang
MRMorgan Roger
Morgan Roger
JSJulien Sarrazin
Julien Sarrazin
CLCaroline Lelandais-Perrault
Caroline Lelandais-Perrault

12 July 2018 in Sensors
Verified
Journal Article
Open access
PDF file
TING ZHANGTING ZHANG
TING ZHANG
JSJulien Sarrazin
Julien Sarrazin
GVGuido Valerio
Guido Valerio
Dan IstrateDan Istrate
Dan Istrate
In this study, a bound-constrained optimization algorithm is applied for estimating physiological data (pulse and breathing rate) of human body using 60 GHz Doppler radar, by detecting displacements induced by breathing and the heartbeat of a human subject. The influence of mutual phasing between the two movements is analyzed in a theoretical framework and the application of optimization algorithms is proved to be able to accurately detect both breathing and heartbeat rates, despite intermodulation effects between them. Different optimization procedures are compared and shown to be more robust to receiver noise and artifacts of random body motion than a direct spectrum analysis. In case of a large-scale constrained bound, a parallel optimization procedure executed in subranges is proposed to realize accurate detection in a reduced span of time.

28 October 2013 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
TMTheodoros Mavridis
Theodoros Mavridis
LPLuca Petrillo
Luca Petrillo
JSJulien Sarrazin
Julien Sarrazin
DLDavid Lautru
David Lautru
ABAziz Benlarbi-Delaï
Aziz Benlarbi-Delaï
PDPhilippe De Doncker
Philippe De Doncker
A fast computation and accurate analytical model for off-body propagation is derived in this paper. The paper discusses the off-body model propagation from an external source to a receiver located on the body. The model is developed for normal incident plane wave by describing the human body with a circular cylinder. We show that the total received electric field around the human body can be written as a creeping wave in the shadow region and as a geometrical optics result for the lit region. It is also shown that at 60 GHz, the shadow boundary width is negligible. The model shows perfect agreement with the experimental results conducted on a perfectly conducting cylinder. Measurements of the creeping wave path gain have been also conducted on a real body to assess the validity of the cylinder assumption. The results have shown a path gain of about 5 dB/cm for the TM case and 3 dB/cm for the TE case. The standard deviation between the measurements and the cylindrical model is about 3.5 dB for both TM and TE cases.