Samuel Lee Mulder

Mr. Samuel Lee Mulder

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
MKMona Kamal
Mona Kamal
Abdallah Sherif Radwan MohamedAbdallah Sherif Radwan Mohamed
Abdallah Sherif Radwan Mohamed
SVStefania Volpe
Stefania Volpe
JZJhankruti Zaveri
Jhankruti Zaveri
MBMartha Portwood Barrow
Martha Portwood Barrow
KHKatherine A. Hutcheson
Katherine A. Hutcheson

10 April 2022 in Cancers
Verified
Journal Article
Open access
PDF file
SMSamuel Lee Mulder
Samuel Lee Mulder
JHJolien Heukelom
Jolien Heukelom
BMBrigid A. McDonald
Brigid A. McDonald
LDLisanne Van Dijk
Lisanne Van Dijk
KWKareem A. Wahid
Kareem A. Wahid
CFClifton David Fuller
Clifton David Fuller
MR-linac devices offer the potential for advancements in radiotherapy (RT) treatment of head and neck cancer (HNC) by using daily MR imaging performed at the time and setup of treatment delivery. This article aims to present a review of current adaptive RT (ART) methods on MR-Linac devices directed towards the sparing of organs at risk (OAR) and a view of future adaptive techniques seeking to improve the therapeutic ratio. This ratio expresses the relationship between the probability of tumor control and the probability of normal tissue damage and is thus an important conceptual metric of success in the sparing of OARs. Increasing spatial conformity of dose distributions to target volume and OARs is an initial step in achieving therapeutic improvements, followed by the use of imaging and clinical biomarkers to inform the clinical decision-making process in an ART paradigm. Pre-clinical and clinical findings support the incorporation of biomarkers into ART protocols and investment into further research to explore imaging biomarkers by taking advantage of the daily MR imaging workflow. A coherent understanding of this road map for RT in HNC is critical for directing future research efforts related to sparing OARs using image-guided radiotherapy (IGRT).

3 March 2025
Verified
Book Chapter
Open access
PDF file
KWKareem A. Wahid
Kareem A. Wahid
CDCem Dede
Cem Dede
DEDina El-Habashy
Dina El-Habashy
SKSerageldin Kamel
Serageldin Kamel
MRMichael Rooney
Michael Rooney
CFClifton David Fuller
Clifton David Fuller
Magnetic resonance (MR)-guided radiation therapy (RT) is enhancing head and neck cancer (HNC) treatment through superior soft tissue contrast and longitudinal imaging capabilities. However, manual tumor segmentation remains a significant challenge, spurring interest in artificial intelligence (AI)-driven automation. To accelerate innovation in this field, we present the Head and Neck Tumor Segmentation for MR-Guided Applications (HNTS-MRG) 2024 Challenge, a satellite event of the 27th International Conference on Medical Image Computing and Computer Assisted Intervention. This challenge addresses the scarcity of large, publicly available AI-ready adaptive RT datasets in HNC and explores the potential of incorporating multi-timepoint data to enhance RT auto-segmentation performance. Participants tackled two HNC segmentation tasks: automatic delineation of primary gross tumor volume (GTVp) and gross metastatic regional lymph nodes (GTVn) on pre-RT (Task 1) and mid-RT (Task 2) T2-weighted scans. The challenge provided 150 HNC cases for training and 50 for final testing hosted on grand-challenge.org using a Docker submission framework. In total, 19 independent teams from across the world qualified by submitting both their algorithms and corresponding papers, resulting in 18 submissions for Task 1 and 15 submissions for Task 2. Evaluation using the mean aggregated Dice Similarity Coefficient showed top-performing AI methods achieved scores of 0.825 in Task 1 and 0.733 in Task 2. These results surpassed clinician interobserver variability benchmarks, marking significant strides in automated tumor segmentation for MR-guided RT applications in HNC.

11 July 2025 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
LMLucas McCullum
Lucas McCullum
SMSamuel Lee Mulder
Samuel Lee Mulder
NWNatalie A. West
Natalie A. West
RARobert Aghoghovbia
Robert Aghoghovbia
AAAlaa Mohamed Shawky Ali
Alaa Mohamed Shawky Ali
CFClifton David Fuller
Clifton David Fuller
Background: SyntheticMR has the capability of generating quantitative relaxometry maps and synthetic contrast‐weighted MRI images in rapid acquisition times. Recently, it has gained attention in the diagnostic community, however, no studies have investigated its feasibility on the MR‐Simulation or MR‐Linac systems, especially as part of the head and neck adaptive radiation oncology workflow. Purpose: Demonstrating its feasibility will facilitate rapid quantitative biomarker extraction, which can be leveraged to guide adaptive radiation therapy decision making. Methods: Two phantoms, two healthy volunteers, and one patient were scanned using SyntheticMR on the MR‐Simulation and MR‐Linac devices with scan times between 4 to 6 min. The correlation between measured and reference quantitative T1, T2, and PD values were determined across clinical ranges in the phantom. Distortion was also studied. Contours of head and neck organs‐at‐risk (OAR) were drawn and applied to extract T1, T2, and PD. These values were plotted against each other, clusters were computed, and their separability significance was determined to evaluate SyntheticMR for differentiating tumor and normal tissue. Results: The Lin's Concordance Correlation Coefficient between the measured and phantom reference values was above 0.97 for both the MR‐Sim and MR‐Linac. No significant levels of distortion were measured. The mean bias between the measured and phantom reference values across repeated scans was below 6% for T1, 11% for T2, and 6% for PD for both the MR‐Sim and MR‐Linac. For T1 versus T2 and T1 versus PD, the GTV contour exhibited perfect purity against neighboring OARs, while being 0.7 for T2 versus PD. All cluster significance levels between the GTV and the nearest OAR, the tongue, using the SigClust method was p < 0.001. Conclusions: The technical feasibility of SyntheticMR was confirmed. Application of this technique to the head and neck adaptive radiation therapy workflow can enrich the current quantitative biomarker landscape.

10 April 2025 in medRxiv
Verified
Preprint
Open access
PDF file
LMLucas McCullum
Lucas McCullum
SMSamuel Lee Mulder
Samuel Lee Mulder
NWNatalie A. West
Natalie A. West
HSHayden Scott
Hayden Scott
DRDiana Carrasco Rojas
Diana Carrasco Rojas
CFClifton David Fuller
Clifton David Fuller
Objective The purpose of this study was to optimize the technical tradeoffs associated with integrating the quantitative maps available from SyntheticMR into the head and neck adaptive radiation oncology workflow. Recent work has begun to investigate SyntheticMR in the adaptive radiation oncology workflow, however no studies have investigated the variation in acquisition parameters and their relationship to the resulting quantitative maps. Filling this gap will facilitate SyntheticMR’s translation to the adaptive radiation therapy setting in the head and neck due to the reduced bias and increase repeatability and reproducibility of its generated quantitative relaxometric biomarkers. Approach The 2D multi-echo multi-delay (MDME) sequence offered from SyntheticMR was acquired on a MR-Simulation and MR-Linac device in both a phantom and healthy volunteers. Scans were optimized across acceleration factors, slice gaps, acquired voxel sizes, repetition times, echo times, refocusing flip angles, noise-limited gradients, number of slices, and echo train lengths. Quantitative relaxometric T1, T2, and PD maps were tested for accuracy using both correlation and mean absolute bias analysis. Noise profiles were evaluated using the coefficient of variation (CoV) in uniform regions of interest. Main Results The following main findings were reported: (1) noise-limited gradients did not affect the bias or CoV, (2) increasing acceleration factor did not affect bias, but it significantly increased CoV, (3) increasing the number of slices resulted in different significant changes in the quantitative parameters between the MR-Simulator and MR-Linac, (4) reducing the echo train length led to generally reduced bias and CoV, and (5) the repeatability CoV was within previously reported literature values on similar scanners. Significance The behavior of the 2D-MDME sequence from SyntheticMR was characterized across a wide range of acquisition parameters designed for ideal head and neck imaging on both the MR-Simulation and MR-Linac devices in phantom and healthy volunteers. Significant differences existed across several acquisition parameters which should be accounted for when making adjustments for application-specific field-of-views, scan time, and desired ranges of T1, T2, and PD. Application of these findings to the development of efficient head and neck adaptive radiation therapy MRI protocols can enrich the current quantitative biomarker landscape allowing for more informed treatment adaptations.

31 August 2024 in medRxiv
Verified
Preprint
Open access
PDF file
LMLucas McCullum
Lucas McCullum
SMSamuel Lee Mulder
Samuel Lee Mulder
NWNatalie West
Natalie West
RARobert Aghoghovbia
Robert Aghoghovbia
AAAlaa Mohamed Shawky Ali
Alaa Mohamed Shawky Ali
CFClifton David Fuller
Clifton David Fuller
Objective: The purpose of this study was to investigate the technical feasibility of integrating the quantitative maps available from SyntheticMR into the head and neck adaptive radiation oncology workflow. While SyntheticMR has been investigated for diagnostic applications, no studies have investigated its feasibility and potential for MR-Simulation or MR-Linac workflow. Demonstrating the feasibility of using this technique will facilitate rapid quantitative biomarker extraction which can be leveraged to guide adaptive radiation therapy decision making. Approach: Two phantoms, two healthy volunteers, and one patient were scanned using SyntheticMR on the MR-Simulation and MR-Linac devices with scan times between four to six minutes. Images in phantoms and volunteers were conducted in a test/retest protocol. The correlation between measured and reference quantitative T1, T2, and PD values were determined across clinical ranges in the phantom. Distortion was also studied. Contours of head and neck organs-at-risk (OAR) were drawn and applied to extract T1, T2, and PD. These values were plotted against each other, clusters were computed, and their separability significance was determined to evaluate SyntheticMR for differentiating tumor and normal tissue. Main Results: The Lin’s Concordance Correlation Coefficient between the measured and phantom reference values was above 0.98 for both the MR-Sim and MR-Linac. No significant levels of distortion were measured. The mean bias between the measured and phantom reference values across repeated scans was below 4% for T1, 7% for T2, and 4% for PD for both the MR-Sim and MR-Linac. For T1 vs. T2 and T1 vs. PD, the GTV contour exhibited perfect purity against neighboring OARs while being 0.7 for T2 vs. PD. All cluster significance levels between the GTV and the nearest OAR, the tongue, using the SigClust method was p < 0.001. Significance: The technical feasibility of SyntheticMR was confirmed. Application of this technique to the head and neck adaptive radiation therapy workflow can enrich the current quantitative biomarker landscape.