Background: SyntheticMR has the capability of generating quantitative relaxometry maps and synthetic contrast‐weighted MRI images in rapid acquisition times. Recently, it has gained attention in the diagnostic community, however, no studies have investigated its feasibility on the MR‐Simulation or MR‐Linac systems, especially as part of the head and neck adaptive radiation oncology workflow. Purpose: Demonstrating its feasibility will facilitate rapid quantitative biomarker extraction, which can be leveraged to guide adaptive radiation therapy decision making. Methods: Two phantoms, two healthy volunteers, and one patient were scanned using SyntheticMR on the MR‐Simulation and MR‐Linac devices with scan times between 4 to 6 min. The correlation between measured and reference quantitative T1, T2, and PD values were determined across clinical ranges in the phantom. Distortion was also studied. Contours of head and neck organs‐at‐risk (OAR) were drawn and applied to extract T1, T2, and PD. These values were plotted against each other, clusters were computed, and their separability significance was determined to evaluate SyntheticMR for differentiating tumor and normal tissue. Results: The Lin's Concordance Correlation Coefficient between the measured and phantom reference values was above 0.97 for both the MR‐Sim and MR‐Linac. No significant levels of distortion were measured. The mean bias between the measured and phantom reference values across repeated scans was below 6% for T1, 11% for T2, and 6% for PD for both the MR‐Sim and MR‐Linac. For T1 versus T2 and T1 versus PD, the GTV contour exhibited perfect purity against neighboring OARs, while being 0.7 for T2 versus PD. All cluster significance levels between the GTV and the nearest OAR, the tongue, using the SigClust method was p < 0.001. Conclusions: The technical feasibility of SyntheticMR was confirmed. Application of this technique to the head and neck adaptive radiation therapy workflow can enrich the current quantitative biomarker landscape.

10 April 2025 in medRxiv
Verified
Preprint
Open access
PDF file
LMLucas McCullum
Lucas McCullum
SMSamuel Lee Mulder
Samuel Lee Mulder
NWNatalie A. West
Natalie A. West
HSHayden Scott
Hayden Scott
DRDiana Carrasco Rojas
Diana Carrasco Rojas
CFClifton David Fuller
Clifton David Fuller
Objective The purpose of this study was to optimize the technical tradeoffs associated with integrating the quantitative maps available from SyntheticMR into the head and neck adaptive radiation oncology workflow. Recent work has begun to investigate SyntheticMR in the adaptive radiation oncology workflow, however no studies have investigated the variation in acquisition parameters and their relationship to the resulting quantitative maps. Filling this gap will facilitate SyntheticMR’s translation to the adaptive radiation therapy setting in the head and neck due to the reduced bias and increase repeatability and reproducibility of its generated quantitative relaxometric biomarkers. Approach The 2D multi-echo multi-delay (MDME) sequence offered from SyntheticMR was acquired on a MR-Simulation and MR-Linac device in both a phantom and healthy volunteers. Scans were optimized across acceleration factors, slice gaps, acquired voxel sizes, repetition times, echo times, refocusing flip angles, noise-limited gradients, number of slices, and echo train lengths. Quantitative relaxometric T1, T2, and PD maps were tested for accuracy using both correlation and mean absolute bias analysis. Noise profiles were evaluated using the coefficient of variation (CoV) in uniform regions of interest. Main Results The following main findings were reported: (1) noise-limited gradients did not affect the bias or CoV, (2) increasing acceleration factor did not affect bias, but it significantly increased CoV, (3) increasing the number of slices resulted in different significant changes in the quantitative parameters between the MR-Simulator and MR-Linac, (4) reducing the echo train length led to generally reduced bias and CoV, and (5) the repeatability CoV was within previously reported literature values on similar scanners. Significance The behavior of the 2D-MDME sequence from SyntheticMR was characterized across a wide range of acquisition parameters designed for ideal head and neck imaging on both the MR-Simulation and MR-Linac devices in phantom and healthy volunteers. Significant differences existed across several acquisition parameters which should be accounted for when making adjustments for application-specific field-of-views, scan time, and desired ranges of T1, T2, and PD. Application of these findings to the development of efficient head and neck adaptive radiation therapy MRI protocols can enrich the current quantitative biomarker landscape allowing for more informed treatment adaptations.

31 August 2024 in medRxiv
Verified
Preprint
Open access
PDF file
LMLucas McCullum
Lucas McCullum
SMSamuel Lee Mulder
Samuel Lee Mulder
NWNatalie West
Natalie West
RARobert Aghoghovbia
Robert Aghoghovbia
AAAlaa Mohamed Shawky Ali
Alaa Mohamed Shawky Ali
CFClifton David Fuller
Clifton David Fuller
Objective: The purpose of this study was to investigate the technical feasibility of integrating the quantitative maps available from SyntheticMR into the head and neck adaptive radiation oncology workflow. While SyntheticMR has been investigated for diagnostic applications, no studies have investigated its feasibility and potential for MR-Simulation or MR-Linac workflow. Demonstrating the feasibility of using this technique will facilitate rapid quantitative biomarker extraction which can be leveraged to guide adaptive radiation therapy decision making. Approach: Two phantoms, two healthy volunteers, and one patient were scanned using SyntheticMR on the MR-Simulation and MR-Linac devices with scan times between four to six minutes. Images in phantoms and volunteers were conducted in a test/retest protocol. The correlation between measured and reference quantitative T1, T2, and PD values were determined across clinical ranges in the phantom. Distortion was also studied. Contours of head and neck organs-at-risk (OAR) were drawn and applied to extract T1, T2, and PD. These values were plotted against each other, clusters were computed, and their separability significance was determined to evaluate SyntheticMR for differentiating tumor and normal tissue. Main Results: The Lin’s Concordance Correlation Coefficient between the measured and phantom reference values was above 0.98 for both the MR-Sim and MR-Linac. No significant levels of distortion were measured. The mean bias between the measured and phantom reference values across repeated scans was below 4% for T1, 7% for T2, and 4% for PD for both the MR-Sim and MR-Linac. For T1 vs. T2 and T1 vs. PD, the GTV contour exhibited perfect purity against neighboring OARs while being 0.7 for T2 vs. PD. All cluster significance levels between the GTV and the nearest OAR, the tongue, using the SigClust method was p < 0.001. Significance: The technical feasibility of SyntheticMR was confirmed. Application of this technique to the head and neck adaptive radiation therapy workflow can enrich the current quantitative biomarker landscape.

18 January 2024 in Radiation Measurements
Verified
Journal Article
Closed access
HSHayden Scott
Hayden Scott
PAPaola Alvarez
Paola Alvarez
RHRebecca Howell
Rebecca Howell
ARAdam Riegel
Adam Riegel
RSRyan Sun
Ryan Sun
SKStephen Kry
Stephen Kry

18 November 2025 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
Paige A TaylorPaige A Taylor
Paige A Taylor
HMHunter Mehrens
Hunter Mehrens
MGMallory C. Glenn
Mallory C. Glenn
FBFre'ETta Brooks
Fre'ETta Brooks
HSHayden Scott
Hayden Scott
SKStephen F. Kry
Stephen F. Kry
The aim of this work was to compare the imaging and radiation oncology core (IROC) on‐site TomoTherapy dosimetry measurement results among institutions and generate a dataset of basic dosimetric properties for TomoTherapy units. Independent ion chamber measurements for nine TomoTherapy units were acquired by IROC physicists between 2008 and 2023. Measurements included percent depth dose (PDD) in a water tank and off axis factors (OAF) in a solid Polystyrene phantom. The independent measurements collected during the on‐site audits for each TomoTherapy system were compared to corresponding TomoTherapy TPS calculations from the institution to assess agreement. Numeric measurement values and comparative ratios are compiled and tabulated according to measurement type (i.e., PDD and OAF). The distribution of the measurements was evaluated, and the mean, standard deviation of the mean, and median values are reported. These data provide an independent guide describing the inherent performance characteristics of TomoTherapy units. Such data may serve as a secondary check for users wishing to verify their beam model commissioning and ongoing quality assurance efforts.