Alaa Mohamed Shawky Ali

Alaa Mohamed Shawky Ali

Auto-generated profile, based on publicly available information

Alaa Mohamed Shawky Ali

Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2023 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
LPLucas Pu
Lucas Pu
JLJoseph K. Leader
Joseph K. Leader
AAAlaa Ali
Alaa Ali
ZGZihan Geng
Zihan Geng
DWDavid o Wilson
David o Wilson
PurposeLung transplantation is the standard treatment for end-stage lung diseases. A crucial factor affecting its success is size matching between the donor’s lungs and the recipient’s thorax. Computed tomography (CT) scans can accurately determine recipient’s lung size, but donor’s lung size is often unknown due to the absence of medical images. We aim to predict donor’s right/left/total lung volume, thoracic cavity, and heart volume from only subject demographics to improve the accuracy of size matching.ApproachA cohort of 4610 subjects with chest CT scans and basic demographics (i.e., age, gender, race, smoking status, smoking history, weight, and height) was used in this study. The right and left lungs, thoracic cavity, and heart depicted on chest CT scans were automatically segmented using U-Net, and their volumes were computed. Eight machine learning models [i.e., random forest, multivariate linear regression, support vector machine, extreme gradient boosting (XGBoost), multilayer perceptron (MLP), decision tree, k-nearest neighbors, and Bayesian regression) were developed and used to predict the volume measures from subject demographics. The 10-fold cross-validation method was used to evaluate the performances of the prediction models. R-squared (R2), mean absolute error (MAE), and mean absolute percentage error (MAPE) were used as performance metrics.ResultsThe MLP model demonstrated the best performance for predicting the thoracic cavity volume (R2: 0.628, MAE: 0.736 L, MAPE: 10.9%), right lung volume (R2: 0.501, MAE: 0.383 L, MAPE: 13.9%), and left lung volume (R2: 0.507, MAE: 0.365 L, MAPE: 15.2%), and the XGBoost model demonstrated the best performance for predicting the total lung volume (R2: 0.514, MAE: 0.728 L, MAPE: 14.0%) and heart volume (R2: 0.430, MAE: 0.075 L, MAPE: 13.9%).ConclusionsOur results demonstrate the feasibility of predicting lung, heart, and thoracic cavity volumes from subject demographics with superior performance compared with available studies in predicting lung volumes.

11 July 2025 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
LMLucas McCullum
Lucas McCullum
SMSamuel Lee Mulder
Samuel Lee Mulder
NWNatalie A. West
Natalie A. West
RARobert Aghoghovbia
Robert Aghoghovbia
AAAlaa Mohamed Shawky Ali
Alaa Mohamed Shawky Ali
CFClifton David Fuller
Clifton David Fuller
Background: SyntheticMR has the capability of generating quantitative relaxometry maps and synthetic contrast‐weighted MRI images in rapid acquisition times. Recently, it has gained attention in the diagnostic community, however, no studies have investigated its feasibility on the MR‐Simulation or MR‐Linac systems, especially as part of the head and neck adaptive radiation oncology workflow. Purpose: Demonstrating its feasibility will facilitate rapid quantitative biomarker extraction, which can be leveraged to guide adaptive radiation therapy decision making. Methods: Two phantoms, two healthy volunteers, and one patient were scanned using SyntheticMR on the MR‐Simulation and MR‐Linac devices with scan times between 4 to 6 min. The correlation between measured and reference quantitative T1, T2, and PD values were determined across clinical ranges in the phantom. Distortion was also studied. Contours of head and neck organs‐at‐risk (OAR) were drawn and applied to extract T1, T2, and PD. These values were plotted against each other, clusters were computed, and their separability significance was determined to evaluate SyntheticMR for differentiating tumor and normal tissue. Results: The Lin's Concordance Correlation Coefficient between the measured and phantom reference values was above 0.97 for both the MR‐Sim and MR‐Linac. No significant levels of distortion were measured. The mean bias between the measured and phantom reference values across repeated scans was below 6% for T1, 11% for T2, and 6% for PD for both the MR‐Sim and MR‐Linac. For T1 versus T2 and T1 versus PD, the GTV contour exhibited perfect purity against neighboring OARs, while being 0.7 for T2 versus PD. All cluster significance levels between the GTV and the nearest OAR, the tongue, using the SigClust method was p < 0.001. Conclusions: The technical feasibility of SyntheticMR was confirmed. Application of this technique to the head and neck adaptive radiation therapy workflow can enrich the current quantitative biomarker landscape.

10 April 2025 in medRxiv
Verified
Preprint
Open access
PDF file
LMLucas McCullum
Lucas McCullum
SMSamuel Lee Mulder
Samuel Lee Mulder
NWNatalie A. West
Natalie A. West
HSHayden Scott
Hayden Scott
DRDiana Carrasco Rojas
Diana Carrasco Rojas
CFClifton David Fuller
Clifton David Fuller
Objective The purpose of this study was to optimize the technical tradeoffs associated with integrating the quantitative maps available from SyntheticMR into the head and neck adaptive radiation oncology workflow. Recent work has begun to investigate SyntheticMR in the adaptive radiation oncology workflow, however no studies have investigated the variation in acquisition parameters and their relationship to the resulting quantitative maps. Filling this gap will facilitate SyntheticMR’s translation to the adaptive radiation therapy setting in the head and neck due to the reduced bias and increase repeatability and reproducibility of its generated quantitative relaxometric biomarkers. Approach The 2D multi-echo multi-delay (MDME) sequence offered from SyntheticMR was acquired on a MR-Simulation and MR-Linac device in both a phantom and healthy volunteers. Scans were optimized across acceleration factors, slice gaps, acquired voxel sizes, repetition times, echo times, refocusing flip angles, noise-limited gradients, number of slices, and echo train lengths. Quantitative relaxometric T1, T2, and PD maps were tested for accuracy using both correlation and mean absolute bias analysis. Noise profiles were evaluated using the coefficient of variation (CoV) in uniform regions of interest. Main Results The following main findings were reported: (1) noise-limited gradients did not affect the bias or CoV, (2) increasing acceleration factor did not affect bias, but it significantly increased CoV, (3) increasing the number of slices resulted in different significant changes in the quantitative parameters between the MR-Simulator and MR-Linac, (4) reducing the echo train length led to generally reduced bias and CoV, and (5) the repeatability CoV was within previously reported literature values on similar scanners. Significance The behavior of the 2D-MDME sequence from SyntheticMR was characterized across a wide range of acquisition parameters designed for ideal head and neck imaging on both the MR-Simulation and MR-Linac devices in phantom and healthy volunteers. Significant differences existed across several acquisition parameters which should be accounted for when making adjustments for application-specific field-of-views, scan time, and desired ranges of T1, T2, and PD. Application of these findings to the development of efficient head and neck adaptive radiation therapy MRI protocols can enrich the current quantitative biomarker landscape allowing for more informed treatment adaptations.

31 August 2024 in medRxiv
Verified
Preprint
Open access
PDF file
LMLucas McCullum
Lucas McCullum
SMSamuel Lee Mulder
Samuel Lee Mulder
NWNatalie West
Natalie West
RARobert Aghoghovbia
Robert Aghoghovbia
AAAlaa Mohamed Shawky Ali
Alaa Mohamed Shawky Ali
CFClifton David Fuller
Clifton David Fuller
Objective: The purpose of this study was to investigate the technical feasibility of integrating the quantitative maps available from SyntheticMR into the head and neck adaptive radiation oncology workflow. While SyntheticMR has been investigated for diagnostic applications, no studies have investigated its feasibility and potential for MR-Simulation or MR-Linac workflow. Demonstrating the feasibility of using this technique will facilitate rapid quantitative biomarker extraction which can be leveraged to guide adaptive radiation therapy decision making. Approach: Two phantoms, two healthy volunteers, and one patient were scanned using SyntheticMR on the MR-Simulation and MR-Linac devices with scan times between four to six minutes. Images in phantoms and volunteers were conducted in a test/retest protocol. The correlation between measured and reference quantitative T1, T2, and PD values were determined across clinical ranges in the phantom. Distortion was also studied. Contours of head and neck organs-at-risk (OAR) were drawn and applied to extract T1, T2, and PD. These values were plotted against each other, clusters were computed, and their separability significance was determined to evaluate SyntheticMR for differentiating tumor and normal tissue. Main Results: The Lin’s Concordance Correlation Coefficient between the measured and phantom reference values was above 0.98 for both the MR-Sim and MR-Linac. No significant levels of distortion were measured. The mean bias between the measured and phantom reference values across repeated scans was below 4% for T1, 7% for T2, and 4% for PD for both the MR-Sim and MR-Linac. For T1 vs. T2 and T1 vs. PD, the GTV contour exhibited perfect purity against neighboring OARs while being 0.7 for T2 vs. PD. All cluster significance levels between the GTV and the nearest OAR, the tongue, using the SigClust method was p < 0.001. Significance: The technical feasibility of SyntheticMR was confirmed. Application of this technique to the head and neck adaptive radiation therapy workflow can enrich the current quantitative biomarker landscape.

12 January 2025 in medRxiv
Verified
Preprint
Open access
PDF file
LMLucas McCullum
Lucas McCullum
ZBZayne Belal
Zayne Belal
WFWarren Floyd
Warren Floyd
AAAlaa Mohamed Shawky Ali
Alaa Mohamed Shawky Ali
NWNatalie West
Natalie West
CFClifton David Fuller
Clifton David Fuller
Background: Currently, a majority of institution-specific automatic MRI-based contouring algorithms are trained, tested, and validated on one contrast weighting (i.e., T2-weighted), however their actual performance within this contrast weighting (i.e., across different repetition times, TR, and echo times, TE) is under-investigated and poorly understood. As a result, external institutions with different scan protocols for the same contrast weighting may experience sub-optimal performance. Purpose: The purpose of this study was to develop a method to evaluate the robustness of automatic contouring algorithms to varying MRI contrast weightings. Methods: One healthy volunteer and one patient was scanned using SyntheticMR on the MR-Simulation device. The parotid and submandibular glands in these subjects were contoured using an automatic contouring algorithm trained on T2-weighted MRIs. For ground truth manual contours, two radiation oncology residents and one pre-resident physician were recruited and their STAPLE consensus was determined. A total of 216 different MRI TR and TE combinations were simulated across T1-, T2-, and PD-weighted contrast ranges using SyntheticMR’s post-processing software, SyMRI. Comparisons between automatic contouring algorithm contours and the ground truth were determined using the Dice similarity coefficient (DSC) and 95 th percentile Hausdorff distance (HD95). Results: Notable differences in the automatic contouring model’s performance were seen across the contrast-weighted range, even within the T2-weighted range. Further, some models even performed as well or better across subsets of the T1-weighted range. The PD-weighted range saw the worst performance. The range of discrepancy in DSC and HD95 exceeded 0.2 and 3.66 mm, respectively, in some structures. In the T2-weighted contrast region where the model was trained, 100%, 40%, 24%, and 57% for the DSC in the left parotid, right parotid, left submandibular, and right submandibular gland, respectively, exceeded interobserver variability. Conclusions: This study demonstrates the variable performance of MRI-based automatic contouring algorithms across varying TR and TE combinations. This methodology could be applied in future studies as a method for evaluating model sensitivity, out of distribution detection ability, and performance drift.