Driving cycle (DC) plays an important role in designing and evaluating EVs, and many Markov chain-based DC construction methods describe driving profiles of unfixed-line vehicles with Markov state transition probability. However, for fixed-line electric vehicles, the time-sequence of microtrips brings huge influences on their brake, drive, and battery management systems. Simply describing topography, traffic, location, driving features, and environment in a stochastic manner cannot reflect the continuity characteristics hidden in a fixed route. Thus, in this paper, we propose a sticky sampling and Markov state transition matrix based DC construction algorithm to describe both randomness and continuity hidden in a fixed route, in which a data structure named “driving pulse chain” was constructed to describe the sequence of the driving scenarios and several Markov state transition matrices were constructed to describe the random distribution of velocity and acceleration in same driving scenarios. Simulation and experimental analysis show that with sliding window and driving pulse chain, the proposed algorithm can describe and reflect the continuity characteristics of topography, traffic, and location. At the same time, the stochastic nature of the driving cycle can be preserved.
We proposed and fabricated a miniaturized multi-core fiber grating vibration sensor. The size of the miniaturized vibration sensor is 10mm × 10mm × 10 mm with a mass of only 0.25g. Finite element analysis and experimental tests were carried out to validate the performance of the vibration sensor. The experiment results indicate that the sensor has a sensitivity of 68.72 pm/g in the X direction and 64.52 pm/g in the Y direction within the operating frequency range of 20-240Hz. The cross-interference between the two directions of vibration measurement falls within 4 %. The sensor is suitable for measuring mechanical vibrations in the mid-low frequency range, especially in cases where size, quality, and distributed measurement are of particular concern.
This paper describes an experimental evaluation of a miniature force and torque sensor in robot-assisted minimally invasive surgery (RMIS). A sensor prototype including the mechanical system and sensing electronics is overviewed. A linear square based static decoupling method is introduced, design and use of a newly invented calibration platform is presented. A dynamic loading mechanism to simulate a heartbeat motion is described. The sensing ranges of the sensor prototype is ±30 N and ±30 N·mm with resolutions of 0.08 N (x, y directions), 0.25 N (z direction), and 2.4 N·mm (rotational directions). It also exhibits a good capability to follow the dynamic loads at a frequency close to a normal heart rate of an adult.
This paper propose an indirect adaptive strategy with impedance control for dual-arm cooperative manipulation, this method generates the desired position of two end-effectors despite lack of object's stiffness, and this position satisfies the requirement of the contact force. Besides, the target force applied by two arms can be determined through force distribution, while the target force tracking can be achieved by impedance controller. Compared with the original impedance control algorithm, this method has stronger adaptability, smaller deviation, and can achieve better tracking of the target force. Simulations are done on two 6-dof robots in Adams and Matlab, the results show the merits of the control algorithm.
25 August 2025 in IEEE Transactions on Instrumentation and Measurement
This study presents a miniature triaxial fiber Bragg grating (FBG) vibration sensor incorporating a novel elliptical guide-angle hybrid flexure hinge structure for stepper motor vibration monitoring. To tackle the multi-objective optimization challenges associated with sensor miniaturization and sensitivity enhancement, we developed a theoretical model and employed response surface methodology (RSM) combined with a multi-objective genetic algorithm (MOGA) for parametric optimization. The validity of the proposed design was verified by finite element analysis (FEA) using ANSYS, through modal and harmonic response simulations. The sensor comprises three orthogonal assembled identical modules, achieving high spatial efficiency with compact dimensions of 20×20×20 mm³ and a mass of 41.47 g. Ultra-short small-diameter FBGs were packaged using a dual-point encapsulation technique. Experimental results indicated that the sensor presented natural frequencies of 1570 Hz (X-axis), 1600 Hz (Y-axis), and 1620 Hz (Z-axis), with corresponding sensitivities reaching 67.34 pm/G, 65.61 pm/G, and 63.48 pm/G, respectively. The operational flat frequency range 20 - 1000 Hz, with the cross-axis interference in non-operational axes below 4% of the primary axis. Real-time triaxial vibration monitoring of a stepper motor under varying conditions confirmed the sensor’s reliability and consistency in multi-degree-of-freedom measurements. With its compact size, high sensitivity, broad frequency range, electromagnetic immunity, and multi-point deployment capability, this sensor is highly applicable for multi-axis medium-to-high frequency vibration measurements in confined spaces within aerospace and mechanical equipment applications.
3 September 2026 in Engineering Applications of Artificial Intelligence