Nicolás Muñoz-Galeano

Dr. Nicolás Muñoz-Galeano

Universidad de Antioquia
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2017 in Electronics
Verified
Journal Article
Open access
PDF file
JBJuan Pablo Rivera Barrera
Juan Pablo Rivera Barrera
Nicolás Muñoz-GaleanoNicolás Muñoz-Galeano
Nicolás Muñoz-Galeano
HSHenry Omar Sarmiento
Henry Omar Sarmiento
Energy storage emerged as a top concern for the modern cities, and the choice of the lithium-ion chemistry battery technology as an effective solution for storage applications proved to be a highly efficient option. State of charge (SoC) represents the available battery capacity and is one of the most important states that need to be monitored to optimize the performance and extend the lifetime of batteries. This review summarizes the methods for SoC estimation for lithium-ion batteries (LiBs). The SoC estimation methods are presented focusing on the description of the techniques and the elaboration of their weaknesses for the use in on-line battery management systems (BMS) applications. SoC estimation is a challenging task hindered by considerable changes in battery characteristics over its lifetime due to aging and to the distinct nonlinear behavior. This has led scholars to propose different methods that clearly raised the challenge of establishing a relationship between the accuracy and robustness of the methods, and their low complexity to be implemented. This paper publishes an exhaustive review of the works presented during the last five years, where the tendency of the estimation techniques has been oriented toward a mixture of probabilistic techniques and some artificial intelligence.

19 February 2020 in Energies
Verified
Journal Article
Open access
PDF file
SSSergio Saldarriaga
Sergio Saldarriaga
Jesús María López-LezamaJesús María López-Lezama
Jesús María López-Lezama
Nicolás Muñoz-GaleanoNicolás Muñoz-Galeano
Nicolás Muñoz-Galeano
The optimal coordination of overcurrent relays (OCRs) has recently become a major challenge owing to the ever-increasing participation of distributed generation (DG) and the multi-looped structure of modern distribution networks (DNs). Furthermore, the changeable operational topologies of microgrids has increased the complexity and computational burden to obtain the optimal settings of OCRs. In this context, classical approaches to OCR coordination might no longer be sufficient to provide a reliable performance of microgrids both in the islanded and grid-connected operational modes. This paper proposes a novel approach for optimal coordination of directional OCRs in microgrids. This approach consists of considering the upper limit of the plug setting multiplier (PSM) as a variable instead of a fixed parameter as usually done in traditional approaches for OCRs coordination. A genetic algorithm (GA) was implemented to optimize the limits of the maximum PSM for the OCRs coordination. Several tests were performed with an IEC microgrid benchmark network considering several operational modes. Results showed the applicability and effectiveness of the proposed approach. A comparison with other studies reported in the specialized literature is provided showing the advantages of the proposed approach.

1 April 2021 in Heliyon
Verified
Journal Article
Open access
SSSergio D. Saldarriaga-Zuluaga
Sergio D. Saldarriaga-Zuluaga
Jesús María López-LezamaJesús María López-Lezama
Jesús María López-Lezama
Nicolás Muñoz-GaleanoNicolás Muñoz-Galeano
Nicolás Muñoz-Galeano
Protection coordination of AC microgrids (MGs) is a challenging task since they can operate either in grid-connected or islanded mode which drastically modifies the fault currents. In this context, traditional approaches to protection coordination, that only consider the time multiplier setting (TMS) as a decision variable may no longer be able to guarantee network security. This paper presents a novel approach for protection coordination in AC MGs that incorporates non-standard characteristic features of directional over-current relays (OCRs). Three optimization variables are considered for each relay: TMS, maximum limit of the plug setting multiplier (PSM) and standard characteristic curve (SCC). The proposed model corresponds to a mixed integer non-linear programming problem. Four metaheuristic techniques were implemented for solving the optimal coordination problem, namely: particle swarm optimization (PSO), genetic algorithm (GA), teaching-learning based optimization (TLBO) algorithm and shuffled frog leaping algorithm (SFLA). Numerous tests were run on an IEC MG as well as with the distribution portion of the IEEE 30-bus test system. Both systems incorporate distributed generation (DG) and feature several modes of operation. A comparison was made with other MG protection coordination approaches proposed in the specialized literature. In all cases, the proposed approach found reduced coordination times, evidencing the applicability and efficacy of the proposed approach.

20 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
José Robinson Ortiz CastrillónJosé Robinson Ortiz Castrillón
José Robinson Ortiz Castrillón
GMGabriel E. Mejia-Ruiz
Gabriel E. Mejia-Ruiz
Nicolás Muñoz-GaleanoNicolás Muñoz-Galeano
Nicolás Muñoz-Galeano
Jesús María López-LezamaJesús María López-Lezama
Jesús María López-Lezama
SSSergio Saldarriaga
Sergio Saldarriaga
Power Factor Correction (PFC) single-phase AC/DC converters are used in several power electronics applications as full wave control rectifiers improving power quality and providing high standards of efficiency. Many papers dealing with the description or use of such topologies have been published in recent years; however, a review that describes and organizes their specific details has not been reported in the technical literature. Therefore, this paper presents an extensive review of PFC single-phase AC/DC converters operating with the Boost converter topology for low and medium voltage as well as and power appliances. A categorization of bridge, semi-bridgeless, and bridgeless, in accordance with the construction characteristics, was carried out in order to unify the technical terminology. Benefits and disadvantages are described and analyzed in detail. Furthermore, a comparison performance in terms of PFC, Total Harmonic Distortion (THD), power capacity, electromagnetic compatibility (EMC), number of elements, and efficiency is included.

20 January 2019 in Energies
Verified
Journal Article
Open access
PDF file
DMDiego Mejía-Giraldo
Diego Mejía-Giraldo
GVGregorio Velásquez-Gomez
Gregorio Velásquez-Gomez
Nicolás Muñoz-GaleanoNicolás Muñoz-Galeano
Nicolás Muñoz-Galeano
JQJuan Bernardo Cano Quintero
Juan Bernardo Cano Quintero
SLSantiago Lemos-Cano
Santiago Lemos-Cano
This paper proposes a strategy for sizing a battery energy storage system (BESS) that supports primary frequency regulation (PFR) service of solar photo-voltaic plants. The strategy is composed of an optimization model and a performance assessment algorithm. The optimization model includes not only investment costs, but also a novel penalty function depending on the state of charge (SoC). This function avoids the existence of a potential inappropriate SoC trajectory during BESS operation that could impede the supply of PFR service. The performance assessment algorithm, fed by the optimization model sizing results, allows the emulation of BESS operation and determines either the success or failure of a particular BESS design. The quality of a BESS design is measured through number of days in which BESS failed to satisfactorily provide PFR and its associated penalization cost. Battery lifetime, battery replacements, and SoC are also key performance indexes that finally permit making better decisions in the election of the best BESS size. The inclusion of multiple BESS operational restrictions under PFR is another important advantage of this strategy since it adds a realistic characterization of BESS to the analysis. The optimization model was coded using GAMS/CPLEX, and the performance assessment algorithm was implemented in MATLAB. Results were obtained using actual frequency data obtained from the Colombian power system; and the resulting BESS sizes show that the number of BESS penalties, caused by failure to provide PFR service, can be reduced to zero at minimum investment cost.

1 January 2017 in Formación universitaria
Verified
Journal Article
Open access
PDF file
FVFernando Villada
Fernando Villada
Jesús María López-LezamaJesús María López-Lezama
Jesús María López-Lezama
Nicolás Muñoz-GaleanoNicolás Muñoz-Galeano
Nicolás Muñoz-Galeano
<![CDATA[En este artículo se analiza la importancia de incluir la educación financiera en el proceso de formación de los profesionales de la ingeniería. La educación financiera se hace cada vez más relevante dado el número creciente de productos que ofrecen los mercados financieros y su efecto en el desarrollo económico de los estados y la calidad de vida de sus ciudadanos. Es evidente que una de las principales causas de las últimas crisis económicas mundiales ha sido la carencia de este tipo de educación. Se analiza el concepto de educación financiera, su relevancia en el mundo moderno y su relación con la ingeniería económica. Finalmente, se describen los principales aspectos que deben ser incluidos en los currículos de ingeniería y se recomiendan algunas medidas para la puesta en práctica de estos conceptos.]]>