David Ferrier

Dr. David Ferrier

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
DFDavid Ferrier
David Ferrier
Kevin HoneychurchKevin Honeychurch
Kevin Honeychurch
This review focuses on recent advances in the application of carbon nanotubes (CNTs) for the development of sensors and biosensors. The paper discusses various configurations of these devices, including their integration in analytical devices. Carbon nanotube-based sensors have been developed for a broad range of applications including electrochemical sensors for food safety, optical sensors for heavy metal detection, and field-effect devices for virus detection. However, as yet there are only a few examples of carbon nanotube-based sensors that have reached the marketplace. Challenges still hamper the real-world application of carbon nanotube-based sensors, primarily, the integration of carbon nanotube sensing elements into analytical devices and fabrication on an industrial scale.

1 June 2015 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
DFDavid Ferrier
David Ferrier
MSMichael P. Shaver
Michael P. Shaver
PHPhilip Hands
Philip Hands

2 July 2021 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Open access
PDF file
DFDavid Ferrier
David Ferrier
JKJanice Kiely
Janice Kiely
RLRichard Luxton
Richard Luxton
This paper presents a review of established and emerging methods for detecting and quantifying the intravenous anaesthetic propofol in solution. There is growing evidence of numerous advantages of total intravenous anaesthesia using propofol compared to conventional volatile-based anaesthesia, both in terms of patient outcomes and environmental impact. However, volatile-based anaesthesia still accounts for the vast majority of administered general anaesthetics, largely due to a lack of techniques for real-time monitoring of patient blood propofol concentration. Herein, propofol detection techniques that have been developed to date are reviewed alongside a discussion of remaining challenges.

28 December 2018 in ACS Sensors
Verified
Journal Article
Open access
GLGeraint J. Langford
Geraint J. Langford
JRJaclyn Raeburn
Jaclyn Raeburn
DFDavid Ferrier
David Ferrier
PHPhilip J. W. Hands
Philip J. W. Hands
MSMichael Patrick Shaver
Michael Patrick Shaver
Morpholino Oligonucleotides (MOs), an uncharged DNA analogue, are functionalized with an acrylamide moiety and incorporated into polymer hydrogels as responsive crosslinks for microRNA sequence detection. The MO crosslinks can be selectively cleaved by a short target analyte single-stranded DNA (ssDNA) sequence based on microRNA, inducing a distinct swelling response measured optically. The MO crosslinks offer significant improvement over DNA based systems through improved thermal stability, no salt requirement and 1000-fold improved sensitivity over a comparative biosensor, facilitating a wider range of sensing conditions. Analysis was also achieved using a mobile phone camera, demonstrating portability.

13 September 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
DFDavid Ferrier
David Ferrier
JKJanice Kiely
Janice Kiely
RLRichard Luxton
Richard Luxton
Despite the growing evidence of improved patient outcomes and of a substantially reduced environmental impact of propofol-based total intravenous anesthesia when compared to volatile-based techniques, the vast majority of general anesthetics still use volatile agents for the maintenance phase. A significant reason for this is the lack of suitable point-of-care, real-time blood propofol measurement techniques. Here we present an enzyme-based electrochemical biosensor for the detection of propofol. Deactivated yeast cells expressing the enzyme cytochrome P450 2B6 are immobilized, alongside gold nanoparticles, within a chitosan film upon the surface of a screen printed electrode. In the presence of the cofactor NADPH, the enzyme converts propofol to a quinone/quinol redox pair that can be detected using simple electrochemistry. This approach avoids the issue of electrode fouling that commonly renders electrochemical propofol sensors impractical. The sensor has a limit of detection of 67 ± 7 ng/ml and a sensitivity of 4.2 ± 0.2 nA/ $\mu \text{g}$ /ml/mm $^{\mathbf {2}}$ . It has been successfully demonstrated in a serum-like solution and has shown a linear response across the therapeutic range of propofol (1 – $10~\mu \text{g}$ /ml). Additionally, the sensor has shown good specificity with regards to potential interfering compounds.

22 January 2025 in Micromachines
Verified
Journal Article
Open access
PDF file
DFDavid Ferrier
David Ferrier
JKJanice Kiely
Janice Kiely
RLRichard Luxton
Richard Luxton
Propofol is one of the most widely used intravenous drugs for anaesthesia and sedation and is one of the most commonly used drugs in intensive care units for the sedation of mechanically ventilated patients. The correct dosage of propofol is of high importance, but there is currently a lack of suitable point-of-care techniques for determining blood propofol concentrations. Here, we present a cytochrome P450 2B6/carbon nanotube/graphene oxide/metal oxide nanocomposite sensor for discrete measurement of propofol concentration. Propofol is converted into a quinol/quinone redox couple by the enzyme and the nanocomposite enables sensitive and rapid detection. The metal oxide nanoparticles are synthesised via green synthesis and a variety of metal oxides and mixed metal oxides are investigated to determine the optimal nanocatalyst. Converting propofol into the redox couple allows for the measurement to take place over different potential ranges, enabling interference from common sources such as paracetamol and uric acid to be avoided. It was found that nanocomposites containing copper titanium oxide nanoparticles offered the best overall performance and electrodes functionalised with such nanocomposites demonstrated a limit of detection in bovine serum of 0.5 µg/mL and demonstrated a linear response over the therapeutic range of propofol with a sensitivity of 4.58 nA/μg/mL/mm2.