Yang Li

Dr. Yang Li

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
SZShanshan Zhao
Shanshan Zhao
JTJianhua Tong
Jianhua Tong
YLYang Li
Yang Li
SJSun Jizhou
Sun Jizhou
Bian ChaoBian Chao
Bian Chao
SXShanhong Xia
Shanhong Xia
An ultramicro interdigital array electrode modified by palladium-gold was developed for nitrate detection in neutral water. The ultramicro interdigital array electrode was fabricated based on silicon substrate by Micro Electro-Mechanical System (MEMS) technique. The nanostructured palladium-gold (Pd-AuNPs) composite sensing film was electrodeposited on the surface of a working electrode by electrochemical method. The synergistic effect of Pd-AuNPs composite was investigated and its enhancement of the catalytic activity and stability was revealed. The Pd-AuNPs modified electrode showed good linearity (R2 = 0.99) from 1 mg/L to 15 mg/L (as N) for nitrate determination in a neutral water environment (pH = 7.2), with a sensitivity of 4.7 μA·mg−1·L. The results showed that the developed Pd-AuNPs-modified ultramicro interdigital array electrode chip can achieve sensitive and environmentally-friendly detection for nitrate in neutral water.

13 June 2016 in Micromachines
Verified
Journal Article
Open access
PDF file
YSYu Song
Yu Song
Bian ChaoBian Chao
Bian Chao
JTJianhua Tong
Jianhua Tong
YLYang Li
Yang Li
SXShanhong Xia
Shanhong Xia
Cadmium(II) is a common water pollutant with high toxicity. It is of significant importance for detecting aqueous contaminants accurately, as these contaminants are harmful to human health and environment. This paper describes the fabrication, characterization, and application of an environment-friendly graphene (Gr)/l-cysteine/gold electrode to detect trace levels of cadmium (Cd) by differential pulse stripping voltammetry (DPSV). The influence of hydrogen overflow was decreased and the current response was enhanced because the modified graphene extended the potential range of the electrode. The Gr/l-cysteine/gold electrode showed high electrochemical conductivity, producing a marked increase in anodic peak currents (vs. the glass carbon electrode (GCE) and boron-doped diamond (BDD) electrode). The calculated detection limits are 1.15, 0.30, and 1.42 µg/L, and the sensitivities go up to 0.18, 21.69, and 152.0 nA·mm−2·µg−1·L for, respectively, the BDD electrode, the GCE, and the Gr/l-cysteine/gold electrode. It was shown that the Gr/l-cysteine/gold-modified electrode is an effective means for obtaining highly selective and sensitive electrodes to detect trace levels of cadmium.

28 November 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
YWYuekun Wang
Yuekun Wang
YXYuhao Xu
Yuhao Xu
JJJinhua Jiang
Jinhua Jiang
YLYang Li
Yang Li
JTJianhua Tong
Jianhua Tong
Bian ChaoBian Chao
Bian Chao
In this study, an ultramicro interdigital electrode array chip (UIEA) was designed and fabricated by using Micro-Electro-Mechanical systems (MEMS) technology, and a portable detection system, using the chip for determination of heavy-metal ions in water, was developed. The working electrode of the UIEA was modified with gold nanoparticles by electrodeposition. The detection sensitivity of the UIEA chip for copper ions was 0.0138 μA·L·μg−1, with the linear range of 0–400 μg/L and the detection limit of 18.89 μg/L (3σ), which was better than that of the compared columnar glassy carbon electrode. The results of the interference experiment verified that the UIEA chip has a certain anti-interference ability against common heavy-metal ions in water, such as Pb2+, Zn2+, and Mg2+ ions. The standard addition method was used to investigate the performance of the developed s ystem for copper ion determination in real water. The recovery range from 87.5% to 94.7% was achieved.

10 March 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
HZHaifei Zhao
Haifei Zhao
YLYang Li
Yang Li
ACAobo Cong
Aobo Cong
JTJianhua Tong
Jianhua Tong
Bian ChaoBian Chao
Bian Chao
Ammonia nitrogen is a common contaminant in water and its determination is important for environmental protection. In this paper, an electrochemical sensor based on an ultramicro interdigitated array electrode (UIAE) chip with optimized construction was fabricated with Micro-Electro-Mechanical System (MEMS) technology and developed to realize the detection of ammonia nitrogen in water. The effects of spacing-to-width ratio and width of the working electrode on UIAE’s electrochemical characteristics and its ammonia nitrogen detection performance were studied by finite element simulation and experiment. The results demonstrated that the smaller the spacing-to-width ratio, the stronger generation–collection effect, and the smaller the electrode width, the stronger the edge effect, which led to an easier steady-state reach, a higher response current, and better ammonia nitrogen determination performance. The fabricated UIAE chip with optimized construction showed the linear detection range of 0.15 mg/L~2.0 mg/L (calculated as N), the sensitivity of 0.4181 μA·L·mg−1, and good anti-interference performance, as well as a long lifetime. UIAE based on bare Pt was successfully applied to ammonia nitrogen detection in water by optimizing structure, which might broaden the methods of ammonia nitrogen detection in water.

11 December 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
YXYuhao Xu
Yuhao Xu
Chenyu XiongChenyu Xiong
Chenyu Xiong
CGChengyao Gao
Chengyao Gao
YLYang Li
Yang Li
Bian ChaoBian Chao
Bian Chao
SXShanhong Xia
Shanhong Xia
Hexavalent chromium (Cr (VI)) has strong oxidizing properties and can result in strong carcinogenic effects on human bodies. Therefore, it is necessary to detect hexavalent chromium sensitively and accurately. This article proposes the gold nanoparticles (AuNPs)–boron-doped diamond (BDD) electrode for the direct determination of chromium with a green and simple detection process by cathodic stripping voltammetry. Gold nanoparticles are used to enhance the detection performance toward Cr (VI). The effect of different pretreatment methods on electrode modification has been studied, and the detection parameters have been optimized. With the optimized conditions, the AuNPs–BDD electrode presents a good linear behavior in a Cr (VI) concentration range of 10 to 1000 μg/L. A low limit of detection of 1.19 μg/L is achieved. The detection process is simple and environmentally friendly. The sensor has been tested for the detection of Cr (VI) in a real water sample with satisfactory results, which indicates potential application of the AuNPs–BDD electrode for the sensitive and onsite detection of Cr (VI).

27 March 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
MHMingjie Han
Mingjie Han
YXYong Xie
Yong Xie
RWRi Wang
Ri Wang
YLYang Li
Yang Li
Bian ChaoBian Chao
Bian Chao
SXShanhong Xia
Shanhong Xia
As a highly toxic heavy metal ion, mercury ion (Hg2+) pollution has caused serious harm to the environment and human health. In this paper, 4-mercaptopyridine (4-MPY) was selected as the sensing material and decorated on the surface of a gold electrode. Trace Hg2+ could be detected by both differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) methods. The proposed sensor displayed a wide detection range from 0.01 μg/L to 500 μg/L with a low limit of detection (LOD) of 0.002 μg/L by EIS measurements. Combined with molecular simulations and electrochemical analyses, the chelating mechanism between Hg2+ and 4-MPY was explored. Through the analysis of binding energy (BE) values and stability constants, 4-MPY showed an excellent selectivity for Hg2+. In the presence of Hg2+, the coordination of Hg2+ with the pyridine nitrogen of 4-MPY was generated at the sensing region, which caused a change in the electrochemical activity of the electrode surface. Due to the strong specific binding capability, the proposed sensor featured excellent selectivity and an anti-interference capability. Furthermore, the practicality of the sensor for Hg2+ detection was validated with the samples of tap water and pond water, which demonstrated its potential application for on-site environmental detection.