28 November 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
YWYuekun Wang
Yuekun Wang
YXYuhao Xu
Yuhao Xu
JJJinhua Jiang
Jinhua Jiang
YLYang Li
Yang Li
JTJianhua Tong
Jianhua Tong
Bian ChaoBian Chao
Bian Chao
In this study, an ultramicro interdigital electrode array chip (UIEA) was designed and fabricated by using Micro-Electro-Mechanical systems (MEMS) technology, and a portable detection system, using the chip for determination of heavy-metal ions in water, was developed. The working electrode of the UIEA was modified with gold nanoparticles by electrodeposition. The detection sensitivity of the UIEA chip for copper ions was 0.0138 μA·L·μg−1, with the linear range of 0–400 μg/L and the detection limit of 18.89 μg/L (3σ), which was better than that of the compared columnar glassy carbon electrode. The results of the interference experiment verified that the UIEA chip has a certain anti-interference ability against common heavy-metal ions in water, such as Pb2+, Zn2+, and Mg2+ ions. The standard addition method was used to investigate the performance of the developed s ystem for copper ion determination in real water. The recovery range from 87.5% to 94.7% was achieved.

23 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Chenyu XiongChenyu Xiong
Chenyu Xiong
YXYuhao Xu
Yuhao Xu
CBChao Bian
Chao Bian
RWRi Wang
Ri Wang
YXYong Xie
Yong Xie
SXShanhong Xia
Shanhong Xia
Mercury ions (Hg2+) pollution in the water environment can cause serious harm to human health. Trace Hg2+ detection is of vital importance for environmental monitoring. Herein, we report a novel design of Ru-MOFs modified gold microelectrode for Hg2+ determination. Ru-MOFs are synthesized directly by the cathodic method on gold microelectrode, with the covered area accurately controlled. Cathodic synthesized Ru-MOFs show good conductivity and are suitable to be used as the electrode surface material directly. The synergy of the pre-deposition process and the adsorption process of Ru-MOFs can effectively improves the performance of the sensor. The results show good linearity (R2 = 0.996) from 0.1 ppb to 5 ppb, with a high sensitivity of 0.583 μA ppb−1 mm−2. The limit of detection is found to be 0.08 ppb and the test process is within 6 min. Most importantly, the senor has a good anti-interference ability and the recoveries are satisfactory. This miniature electrochemical sensor has the potential for on-site detection of trace mercury in the field.

11 December 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
YXYuhao Xu
Yuhao Xu
Chenyu XiongChenyu Xiong
Chenyu Xiong
CGChengyao Gao
Chengyao Gao
YLYang Li
Yang Li
Bian ChaoBian Chao
Bian Chao
SXShanhong Xia
Shanhong Xia
Hexavalent chromium (Cr (VI)) has strong oxidizing properties and can result in strong carcinogenic effects on human bodies. Therefore, it is necessary to detect hexavalent chromium sensitively and accurately. This article proposes the gold nanoparticles (AuNPs)–boron-doped diamond (BDD) electrode for the direct determination of chromium with a green and simple detection process by cathodic stripping voltammetry. Gold nanoparticles are used to enhance the detection performance toward Cr (VI). The effect of different pretreatment methods on electrode modification has been studied, and the detection parameters have been optimized. With the optimized conditions, the AuNPs–BDD electrode presents a good linear behavior in a Cr (VI) concentration range of 10 to 1000 μg/L. A low limit of detection of 1.19 μg/L is achieved. The detection process is simple and environmentally friendly. The sensor has been tested for the detection of Cr (VI) in a real water sample with satisfactory results, which indicates potential application of the AuNPs–BDD electrode for the sensitive and onsite detection of Cr (VI).

23 April 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
YXYong Xie
Yong Xie
Bian ChaoBian Chao
Bian Chao
MHMingjie Han
Mingjie Han
RWRi Wang
Ri Wang
YLYang Li
Yang Li
SXShanhong Xia
Shanhong Xia
A highly sensitive and accurate dual-signal strategy is developed for trace Cu2+ detection based on the inner filter effect (IFE) between Tween 20-gold nanoparticles (AuNPs) and CdSe/ZnS quantum dots (QDs). Tween 20-AuNPs are utilized as colorimetric probes and excellent fluorescent absorbers. The fluorescence of CdSe/ZnS QDs can be quenched efficiently by Tween 20-AuNPs via IFE. In the presence of D-penicillamine, D-penicillamine induces the aggregation of Tween 20-AuNPs and the fluorescent recovery of CdSe/ZnS QDs at high ionic strength. Upon addition of Cu2+, D-penicillamine tends to selectively chelate with Cu2+ and then forms the mixed-valence complexes, which consequently inhibits the aggregation of Tween 20-AuNPs and the fluorescent recovery. The dual-signal method is used to quantitatively detect trace Cu2+, with low detection limits of 0.57 μg/L and 0.36 μg/L for colorimetry and fluorescence, respectively. In addition, the proposed method using a portable spectrometer is applied to the detection of Cu2+ in water. This sensitive, accurate and miniature sensing system has potential in environmental evaluations.

27 November 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
Chenyu XiongChenyu Xiong
Chenyu Xiong
YHYUN HUI
YUN HUI
RWRi Wang
Ri Wang
Bian ChaoBian Chao
Bian Chao
YXYuhao Xu
Yuhao Xu
SXShanhong Xia
Shanhong Xia
Trace mercury ion (Hg2+) detection is important for environmental monitoring and water safety. In this work, we study the electrochemical strategy to detect trace Hg2+ based on the preconcentration of temperature-controlled N-octylpyridinium tetrafluoroborate ([OPy][BF4]) dispersive liquid–liquid microextraction. The [OPy][BF4] selectively extracted Hg2+ from aqueous solution by the adsorption of unsaturated N in [OPy][BF4], which increased the concentration of Hg2+ and decreased that of other interference ions. It was noted that the adsorption of [OPy][BF4] to Hg2+ was weakened by aqueous solution. Hence, after extraction, precipitated [OPy][BF4] was diluted by a buffer solution comprising a mixture of water and acetonitrile to release Hg2+ and the single was detected by electrochemistry. Water is proposed to release Hg2+ adsorbed by [OPy][BF4], and the acetonitrile serves as a co-solvent in buffer solution. Sensitivity and anti-inference ability of sensors were improved using the proposed method and Hg2+ releasing procedure. The detection limit (S/N = 3) of the sensor is 0.0315 μg/L with a linear range from 0.1 to 1 μg/L. And the sensor exhibits good recovery with an range from 106 % to 118%, which has great potential for trace Hg2+ determination.