Mercury ions (Hg) pollution in the water environment can cause serious harm to human health. Trace Hg detection is of vital importance for environmental monitoring. Herein, we report a novel design of Ru-MOFs modified gold microelectrode for Hg determination. Ru-MOFs are synthesized directly by the cathodic method on gold microelectrode, with the covered area accurately controlled. Cathodic synthesized Ru-MOFs show good conductivity and are suitable to be used as the electrode surface material directly. The synergy of the pre-deposition process and the adsorption process of Ru-MOFs can effectively improves the performance of the sensor. The results show good linearity (R = 0.996) from 0.1 ppb to 5 ppb, with a high sensitivity of 0.583 A ppb mm. The limit of detection is found to be 0.08 ppb and the test process is within 6 min. Most importantly, the senor has a good anti-interference ability and the recoveries are satisfactory. This miniature electrochemical sensor has the potential for on-site detection of trace mercury in the field.
As a highly toxic heavy metal ion, mercury ion (Hg2+) pollution has caused serious harm to the environment and human health. In this paper, 4-mercaptopyridine (4-MPY) was selected as the sensing material and decorated on the surface of a gold electrode. Trace Hg2+ could be detected by both differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) methods. The proposed sensor displayed a wide detection range from 0.01 μg/L to 500 μg/L with a low limit of detection (LOD) of 0.002 μg/L by EIS measurements. Combined with molecular simulations and electrochemical analyses, the chelating mechanism between Hg2+ and 4-MPY was explored. Through the analysis of binding energy (BE) values and stability constants, 4-MPY showed an excellent selectivity for Hg2+. In the presence of Hg2+, the coordination of Hg2+ with the pyridine nitrogen of 4-MPY was generated at the sensing region, which caused a change in the electrochemical activity of the electrode surface. Due to the strong specific binding capability, the proposed sensor featured excellent selectivity and an anti-interference capability. Furthermore, the practicality of the sensor for Hg2+ detection was validated with the samples of tap water and pond water, which demonstrated its potential application for on-site environmental detection.
A highly sensitive and accurate dual-signal strategy is developed for trace Cu2+ detection based on the inner filter effect (IFE) between Tween 20-gold nanoparticles (AuNPs) and CdSe/ZnS quantum dots (QDs). Tween 20-AuNPs are utilized as colorimetric probes and excellent fluorescent absorbers. The fluorescence of CdSe/ZnS QDs can be quenched efficiently by Tween 20-AuNPs via IFE. In the presence of D-penicillamine, D-penicillamine induces the aggregation of Tween 20-AuNPs and the fluorescent recovery of CdSe/ZnS QDs at high ionic strength. Upon addition of Cu2+, D-penicillamine tends to selectively chelate with Cu2+ and then forms the mixed-valence complexes, which consequently inhibits the aggregation of Tween 20-AuNPs and the fluorescent recovery. The dual-signal method is used to quantitatively detect trace Cu2+, with low detection limits of 0.57 μg/L and 0.36 μg/L for colorimetry and fluorescence, respectively. In addition, the proposed method using a portable spectrometer is applied to the detection of Cu2+ in water. This sensitive, accurate and miniature sensing system has potential in environmental evaluations.
Trace mercury ion (Hg) detection is important for environmental monitoring and water safety. In this work, we study the electrochemical strategy to detect trace Hg based on the preconcentration of temperature-controlled N-octylpyridinium tetrafluoroborate ([OPy][BF]) dispersive liquid–liquid microextraction. The [OPy][BF] selectively extracted Hg from aqueous solution by the adsorption of unsaturated N in [OPy][BF], which increased the concentration of Hg and decreased that of other interference ions. It was noted that the adsorption of [OPy][BF] to Hg was weakened by aqueous solution. Hence, after extraction, precipitated [OPy][BF] was diluted by a buffer solution comprising a mixture of water and acetonitrile to release Hg and the single was detected by electrochemistry. Water is proposed to release Hg adsorbed by [OPy][BF], and the acetonitrile serves as a co-solvent in buffer solution. Sensitivity and anti-inference ability of sensors were improved using the proposed method and Hg releasing procedure. The detection limit (S/N = 3) of the sensor is 0.0315 μg/L with a linear range from 0.1 to 1 μg/L. And the sensor exhibits good recovery with an range from 106 % to 118%, which has great potential for trace Hg determination.