Dmitry Terpelov

Dr. Dmitry Terpelov

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2017 in Instruments and Experimental Techniques
Verified
Journal Article
Closed access
PDF file
DTDmitry Terpelov
Dmitry Terpelov
SKS. Yu. Ksenofontov
S. Yu. Ksenofontov
GGG. V. Gelikonov
G. V. Gelikonov
VGV. M. Gelikonov
V. M. Gelikonov
PSP. A. Shilyagin
P. A. Shilyagin
We describe a system of optical spectrum registration at the output of an interferometer with controlled phase shifts for an experimental device intended for visualizing the internal structure of an optically turbid specimen, using the method of spectral domain optical coherence tomography. A device for spectral domain optical coherence tomography based on a common-path optical scheme with a USB 3.0 interface for inputting data into a computer has been developed. An imaging speed of 91 912 A-scans/s has been attained. At the achieved speed, a series of live experiments were carried out to visualize the internal structure of skin tissues from a finger and front segments of an eye.

31 May 2012 in Quantum Electronics
Verified
Journal Article
Closed access
GGGrigory Gelikonov
Grigory Gelikonov
GGGrigory Gelikonov
Grigory Gelikonov
DTDmitry Terpelov
Dmitry Terpelov
DSD V Shabanov
D V Shabanov
Pavel A. ShilyaginPavel A. Shilyagin
Pavel A. Shilyagin

26 November 2021 in Photonics
Verified
Journal Article
Open access
PDF file
ESEvgeny P. Sherstnev
Evgeny P. Sherstnev
Pavel A. ShilyaginPavel A. Shilyagin
Pavel A. Shilyagin
DTDmitry Terpelov
Dmitry Terpelov
VGValentin M. Gelikonov
Valentin M. Gelikonov
GGGrigory Gelikonov
Grigory Gelikonov
We present an improved analytical model of a spectrometer for optical coherence tomography (OCT), which more accurately describes the OCT in-depth sensitivity fall-off. The model considers the intrinsic spectral resolution of the dispersive element and the influence of additional components (inequidistance-correcting prism). The model is validated by experimental data obtained both from other studies and our own experiments. The influence of the frequency response of the CCD electrical circuit and the analog-to-digital converter to the OCT signal fall-off was also detected and was shown to be significant in some cases.

1 July 2019 in Radiophysics and Quantum Electronics
Verified
Journal Article
Closed access
PDF file
SKSergey Ksenofontov
Sergey Ksenofontov
DTDmitry Terpelov
Dmitry Terpelov
GGGrigory Gelikonov
Grigory Gelikonov
Pavel A. ShilyaginPavel A. Shilyagin
Pavel A. Shilyagin
GGGrigory Gelikonov
Grigory Gelikonov