Bubbles will reduce the electric strength of transformer oil, and even result in the breakdown of the insulation. This paper has studied the breakdown voltages of transformer oil and oil-impregnated pressboard under alternating current (AC) and direct current (DC) voltages. In this paper, three types of electrodes were applied: cylinder-plan electrodes, sphere-plan electrodes, and cone-plan electrodes, and the breakdown voltages were measured in both no bubbles and bubbles. The sphere-sphere electrodes were used to study the breakdown voltage of the oil-impregnated pressboard. The results showed that under the influence of bubble, the breakdown voltage of the cylinder-plan electrode dropped the most, and the breakdown voltage of the cone-plan electrode dropped the least. The bubbles motion was the key factor of the breakdown. The discharge types of the oil-impregnated pressboard were different with bubbles, and under DC, the main discharge type was flashover along the oil-impregnated pressboard, while under AC, the main discharge type was breakdown through the oil-impregnated pressboard.
The condition and health of large oil-immersed power transformers’ insulation have a direct impact on the safety and stability of the power grid. Therefore, it is crucial to investigate the aging characteristics of oil–paper insulation in power transformers. In this study, we developed a computational model for reclosing current calculation and multiphysics coupling models for magnetic-circuit-force, electrostatic field, and temperature field simulations. The calculated aging resulted in a mechanical stress of 8.71 MPa, an electric field strength of 2.26 × 106 V/m, and a temperature of 113.7 °C. We conducted combined electrical–thermal–mechanical aging tests on the oil–paper insulation and measured various insulating paper performance parameters at different aging stages. Our study revealed that both the mechanical and electrical properties of the insulating paper deteriorated in both aging groups. However, the changes were more pronounced in the electrical–thermal–mechanical aging group compared to the electrical–thermal aging group, indicating that mechanical stress accelerated the aging process of the insulating paper. In the early stages of aging, the rate of performance changes in the electrical–thermal aging group was similar to that in the electrical–thermal–mechanical aging group. However, as the aging time increased, the degradation of performance induced by mechanical aging became more significant. This suggests that the insulating paper’s resistance to mechanical damage, specifically short-circuit resistance, noticeably decreased after prolonged aging.
The poly-m-phenyleneisophthalamide (PMIA) is widely used in the electrical field due to its numerous favorable characteristics, but its poor thermal conductivity limits its application. In this study, PMIA was modified with nano-silica (SiO2) to improve its thermal and mechanical properties. Using iso-phthalic acid and m-phenylenediamine as monomers, the changes in the thermodynamic properties and microstructure parameters of SiO2-modified PMIA were analyzed using molecular dynamics before and after modification in the temperature range of 250~450 K. It was found that adding SiO2 improves the Young’s modulus and Shear modulus of PMIA, and the mechanical properties of PMIA, and SiO2/PMIA composites deteriorate with increasing temperature, but the mechanical properties of SiO2/PMIA composites are always better than those of pure PMIA in the temperature range of electrical equipment. Meanwhile, after doping SiO2 with the radius of 8 Å, the glass transition temperature of PMIA increases by 27.11 K, and its thermal conductivity increases from 0.249 W m−1 K−1 to 0.396 W m−1 K−1. When SiO2 is added to PMIA, the thermal expansion coefficient of PMIA will decrease in both glass and rubber states, and its thermal stability will improve. In terms of microstructure parameters, the free volume distribution of the SiO2/PMIA model is less easily dispersed than that of the PMIA model, indicating that the addition of SiO2 can improve the related properties of PMIA by hindering the movement of molecular chains.
Identifying the main byproducts of SF6 decomposition proves to be an effective strategy for determining the nature and severity of internal discharge faults in gas-insulated switchgears (GISs). In this research, it was suggested to utilize the coordination polymer Zr-MOF-808 as a sensor for the main byproducts of SF6 decomposition. This study examined the adsorption of SF6 and its main decomposition products (CF4, CS2, SO2, SO2F2, and SOF2) on Zr-MOF-808, utilizing Gaussian16 simulation software through a method anchored on quantum chemistry. Adsorption parameters were calculated and analyzed, including binding energy, charge transfer, adsorption distance, along with variations in bond length, bond angle, density of states, and frontier orbital of gas molecules. Our research indicated that the Zr-MOF-808 cluster demonstrated varying degrees of chemical adsorption for the six gases, leading to differential conductivity changes in each system following adsorption. Consequently, the detection of resistance value alterations in the materials would allow for the identification of the gas products.
The dimension and surface state of shielding fittings in ultra high voltage direct current (UHVDC) converter station valve halls have a great influence on their surface electric field and switching impulse characteristics, which are important parameters confirming the air gap distance in the valve hall. The characteristics of impulse discharge under different lengths, dent degrees and burrs around the scratches of Φ1.3 m shield balls with a 2 m sphere-plane gap length were tested, in the UHVDC testing base of the Hebei Electric Power Research Institute. The discharge characteristics under the influence of the surface scratches of the shield ball were obtained. The results demonstrate that the discharge voltage of sphere-plane gap decreases obviously when there are unpolished scratches on the surface of the shield ball. However, when the scratches are polished, the discharge voltage has no significant impact. At the same time, a 1:1 full-scale impulse test model was established based on the finite element method. The electric field intensity and the space electric field distribution of the shield ball were obtained under the influence of scratches with or without burrs. The results of the simulation show that when the surface of the shield ball is smooth, the electric field distribution around it is even. The electric field intensity on the surface of the shield ball increases obviously when there are burrs around the scratches. When there is no burr around the scratches, the length and depth of the scratches have no obvious effect on its electric field distribution. Meanwhile, calculation results are consistent with test results. The results can provide an important basis for the design and optimization of shielding fittings, and technical support for its localization.
The long-term safe and stable operation of oil-impregnated paper (OIP) bushings is of great significance to the operation of power systems. With the growth of OIP bushing, its internal insulation will gradually decay. Aramid insulation paper has excellent thermal aging characteristics and its insulation performance can be improved by using nano-modification technology. In this paper, the nano-SiO2 particles were used as the modified additives, and the modified aramid insulation paper was prepared through four steps: ultrasonic stirring, fiber dissociation, paper sample copying and superheated calendering. The microscopic physical morphology and chemical components of the insulation specimens before and after modification were analyzed by atomic force microscopy (AFM), scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS), and an OIP bushing model based on the modified aramid insulation paper was constructed and its electric field distribution was analyzed. The simulation results show that the use of SiO2-modified aramid insulation paper can improve the electric field distribution of OIP bushings and increase the operating life of power transformers.