Marco Scarpetta

Dr. Marco Scarpetta

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
NGNicola Giaquinto
Nicola Giaquinto
MSMarco Scarpetta
Marco Scarpetta
Maurizio SpadavecchiaMaurizio Spadavecchia
Maurizio Spadavecchia
GAGregorio Andria
Gregorio Andria
This paper explores the use of deep learning-based computer vision for real-time monitoring of the flow in intravenous (IV) infusions. IV infusions are among the most common therapies in hospitalized patients and, given that both over-infusion and under-infusion can cause severe damages, monitoring the flow rate of the fluid being administered to patients is very important for their safety. The proposed system uses a camera to film the IV drip infusion kit and a deep learning-based algorithm to classify acquired frames into two different states: frames with a drop that has just begun to take shape and frames with a well-formed drop. The alternation of these two states is used to count drops and derive a measurement of the flow rate of the drip. The usage of a camera as sensing element makes the proposed system safe in medical environments and easier to be integrated into current health facilities. Experimental results are reported in the paper that confirm the accuracy of the system and its capability to produce real-time estimates. The proposed method can be therefore effectively adopted to implement IV infusion monitoring and control systems.

19 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Filippo AttivissimoFilippo Attivissimo
Filippo Attivissimo
Luisa De PalmaLuisa De Palma
Luisa De Palma
Attilio Di NisioAttilio Di Nisio
Attilio Di Nisio
MSMarco Scarpetta
Marco Scarpetta
Anna LanzollaAnna Lanzolla
Anna Lanzolla
In this paper, new features relevant to blood pressure (BP) estimation using photoplethysmography (PPG) are presented. A total of 195 features, including the proposed ones and those already known in the literature, have been calculated on a set composed of 50,000 pulses from 1080 different patients. Three feature selection methods, namely Correlation-based Feature Selection (CFS), RReliefF and Minimum Redundancy Maximum Relevance (MRMR), have then been applied to identify the most significant features for BP estimation. Some of these features have been extracted through a novel PPG signal enhancement method based on the use of the Maximal Overlap Discrete Wavelet Transform (MODWT). As a matter of fact, the enhanced signal leads to a reliable identification of the characteristic points of the PPG signal (e.g., systolic, diastolic and dicrotic notch points) by simple means, obtaining results comparable with those from purposely defined algorithms. For systolic points, mean and std of errors computed as the difference between the locations obtained using a purposely defined already known algorithm and those using the MODWT enhancement are, respectively, 0.0097 s and 0.0202 s; for diastolic points they are, respectively, 0.0441 s and 0.0486 s; for dicrotic notch points they are 0.0458 s and 0.0896 s. Hence, this study leads to the selection of several new features from the MODWT enhanced signal on every single pulse extracted from PPG signals, in addition to features already known in the literature. These features can be employed to train machine learning (ML) models useful for estimating systolic blood pressure (SBP) and diastolic blood pressure (DBP) in a non-invasive way, which is suitable for telemedicine health-care monitoring.

1 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MSMarco Scarpetta
Marco Scarpetta
Maurizio SpadavecchiaMaurizio Spadavecchia
Maurizio Spadavecchia
FAFrancesco Adamo
Francesco Adamo
MRMattia Alessandro Ragolia
Mattia Alessandro Ragolia
NGNicola Giaquinto
Nicola Giaquinto
In this paper, a convolutional neural network for the detection and characterization of impedance discontinuity points in cables is presented. The neural network analyzes time-domain reflectometry signals and produces a set of estimated discontinuity points, each of them characterized by a class describing the type of discontinuity, a position, and a value quantifying the entity of the impedance discontinuity. The neural network was trained using a great number of simulated signals, obtained with a transmission line simulator. The transmission line model used in simulations was calibrated using data obtained from stepped-frequency waveform reflectometry measurements, following a novel procedure presented in the paper. After the training process, the neural network model was tested on both simulated signals and measured signals, and its detection and accuracy performances were assessed. In experimental tests, where the discontinuity points were capacitive faults, the proposed method was able to correctly identify 100% of the discontinuity points, and to estimate their position and entity with a root-mean-squared error of 13 cm and 14 pF, respectively.

8 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MSMarco Scarpetta
Marco Scarpetta
Andrea CataldoAndrea Cataldo
Andrea Cataldo
Maurizio SpadavecchiaMaurizio Spadavecchia
Maurizio Spadavecchia
Emanuele PiuzziEmanuele Piuzzi
Emanuele Piuzzi
AMAntonio Masciullo
Antonio Masciullo
NGNicola Giaquinto
Nicola Giaquinto
The problem of water scarcity affects many areas of the world due to water mismanagement and overconsumption and, more recently, to climate change. Monitoring the integrity of distribution systems is, therefore, increasingly important to avoid the waste of clean water. This paper presents a new signal processing technique for enhancing the performance of the methodology of leak detection in water distribution pipes based on time domain reflectometry (TDR). The new technique is based on a particular kind of TDR inversion (spatial TDR) based on a “gray-box” lumped parameter model of the system. The model does not include, e.g., radiative phenomena, non-TEM (transverse electromagnetic) modes etc. but is capable of reproducing accurately the complicated reflectograms obtained by a TDR leak detection system assuming a proper profile of capacitance per unit length along the sensing element. Even more importantly, the model is identified using only the reflectograms taken by the system with very little prior information about the system components. The developed technique is able to estimate with good accuracy, from reflectograms with unclear or ambiguous interpretation, the position and the extension of a region where water is located. The measurement is obtained without prior electromagnetic characterization of the TDR system components and without the need of modeling or quantifying a number of electromagnetic effects typical of on-site measurements.

5 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
GAGregorio Andria
Gregorio Andria
MSMarco Scarpetta
Marco Scarpetta
Maurizio SpadavecchiaMaurizio Spadavecchia
Maurizio Spadavecchia
Paolo AffusoPaolo Affuso
Paolo Affuso
NGNicola Giaquinto
Nicola Giaquinto
Monitoring the shoreline over time is essential to quickly identify and mitigate environmental issues such as coastal erosion. Monitoring using satellite images has two great advantages, i.e., global coverage and frequent measurement updates; but adequate methods are needed to extract shoreline information from such images. To this purpose, there are valuable non-supervised methods, but more recent research has concentrated on deep learning because of its greater potential in terms of generality, flexibility, and measurement accuracy, which, in contrast, derive from the information contained in large datasets of labeled samples. The first problem to solve, therefore, lies in obtaining large datasets suitable for this specific measurement problem, and this is a difficult task, typically requiring human analysis of a large number of images. In this article, we propose a technique to automatically create a dataset of labeled satellite images suitable for training machine learning models for shoreline detection. The method is based on the integration of data from satellite photos and data from certified, publicly accessible shoreline data. It involves several automatic processing steps, aimed at building the best possible dataset, with images including both sea and land regions, and correct labeling also in the presence of complicated water edges (which can be open or closed curves). The use of independently certified measurements for labeling the satellite images avoids the great work required to manually annotate them by visual inspection, as is done in other works in the literature. This is especially true when convoluted shorelines are considered. In addition, possible errors due to the subjective interpretation of satellite images are also eliminated. The method is developed and used specifically to build a new dataset of Sentinel-2 images, denoted SNOWED; but is applicable to different satellite images with trivial modifications. The accuracy of labels in SNOWED is directly determined by the uncertainty of the shoreline data used, which leads to sub-pixel errors in most cases. Furthermore, the quality of the SNOWED dataset is assessed through the visual comparison of a random sample of images and their corresponding labels, and its functionality is shown by training a neural model for sea–land segmentation.

1 July 2022 in Journal of Instrumentation
Verified
Journal Article
Closed access
MSMarco Scarpetta
Marco Scarpetta
MSM. Spadavecchia
M. Spadavecchia
GAG. Andria
G. Andria
MRM.A. Ragolia
M.A. Ragolia
NGN. Giaquinto
N. Giaquinto
In this paper, a method based on the usage of a smartphone for measuring simultaneously both heartbeat intervals and respiratory intervals is presented. In particular, the commodity accelerometer of a smartphone is used for measuring the seismocardiographic signal generated by heart activity and the acceleration due to breathing movements. The measurement is performed with the subject laying down, placing the smartphone on his/her xiphoid process. Signal processing algorithms are presented in the paper that can produce an accurate estimation of heartbeat and respiratory intervals from the measured acceleration signals. A metrological validation of the heartbeat and respiratory intervals estimates obtained with the proposed method is carried out by comparison with measurements obtained using an electrocardiograph and a spirometer. Two practical examples of applications of the measured quantities are finally reported, that are the measurement of the Heart Rate Variability from heartbeat intervals and of the Respiratory Sinus Arrhythmia from both the heartbeat intervals and the respiratory signal.