Yangyang Wu

Dr. Yangyang Wu


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 January 2024 in Processes
Verified
Journal Article
Open access
PDF file
FMFanbin Meng
Fanbin Meng
春车春影 车
春影 车
YWYangyang Wu
Yangyang Wu
JWJiachao Wei
Jiachao Wei
JRJiancheng Rong
Jiancheng Rong
ZWZhihua Wang
Zhihua Wang
The thermal storage performance of shell and tube phase change heat storage units is greatly influenced by the thermophysical parameters of the phase change material (PCM). Therefore, we use numerical simulations to examine how the thermal storage capability of shell and tube phase change heat storage units is affected by thermophysical parameters such as specific heat capacity, thermal conductivity, and latent heat of phase change. The findings indicate that while the rate of temperature increase and the rate of the PCM melting both slow down as specific heat capacity increases, the overall heat storage increases. Within the specified range of parameters, the average rate of heat storage increases by approximately 4% for every 50% increase in specific heat capacity. The PCM’s rate of temperature rise slows down and its overall heat storage capacity rises throughout the middle stage of the phase change heat storage process as the latent heat of phase change grows. The average heat storage rate increases by approximately 6% and 22% for every 50% increase in latent heat and thermal conductivity, respectively. Notably, when the thermal conductivity is enhanced by a factor of 1.5, the average heat storage rate experiences an almost 50% increase. The thermal conductivity of the PCM has a negligible impact on total heat storage. The choice and use of the PCM in shell and tube phase change heat storage heat exchangers has a theoretical and empirical foundation thanks to this work.

10 August 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
FMFanbin Meng
Fanbin Meng
YYYang Yu
Yang Yu
YWYangyang Wu
Yangyang Wu
Dong LiDong Li
Dong Li
XZXuefeng Zhao
Xuefeng Zhao
ZWZhihua Wang
Zhihua Wang
Heating furnaces fueled by fossil fuels are commonly utilized in oilfields to provide heat to the settling tank, which heats the layer of crude oil. However, this traditional heating method consumes a significant amount of oil and gas resources, resulting in low energy utilization and environmental pollution. As the water content of the extracted crude oil increases over time, the operating costs of the settling tanks also continue to increase. Therefore, it is crucial to develop and implement clean and efficient heating technologies to facilitate the efficient operation of settling tanks. This paper proposes a solar–gas combined heating technology for settling tanks. A simulation model for the solar–gas combined heating system for the settling tank is constructed, considering the overall perspective of the system. The simulation model analyzes the impact of the control strategy for the oil collection period of the settling tank on the system performance. This analysis covers various aspects including the heat collection of the solar collector, the heat supply of the gas boiler, and the heat storage and release of the phase-change heat storage tank. The results demonstrate that when the oil collection cycle is Scheme E (4:00–8:00), the collector achieves the highest annual cumulative heat collection, the gas boiler provides the lowest annual total heat supply, and the phase-change heat storage tank exhibits the highest heat storage and release efficiency. Over the course of the system’s 15 year service life, the settling tank solar–gas combined heating system saves 727,988.69 MJ of energy annually, resulting in total energy-saving costs of CNY 397,007. The dynamic investment payback period is estimated at 9.14 years, and the system reduces CO2 emissions by 753,069.8 kg.

7 September 2026 in Energies
Verified
Journal Article
Open access
PDF file
MWMingji Wang
Mingji Wang
YWYangyang Wu
Yangyang Wu
YZYinxia Zhuang
Yinxia Zhuang
YZYinxia Zhuang
Yinxia Zhuang
Phase change thermal storage tanks are important components of clean energy heating systems, and their charging performance depends strongly on storage-unit geometry and heat transfer fluid (HTF) conditions. This study develops a two-dimensional numerical model of a hexagonal honeycomb phase change storage unit and investigates the effects of cell number, HTF inlet temperature, inlet velocity, and fluid type under an approximately constant PCM inventory. Compared with the 4-cell configuration, the 9-, 16-, and 25-cell units reduce the times required to reach an average liquid fraction of 0.8 by 58.3%, 73.9%, and 83.5%, respectively. At 9000 s, the total stored heat of the 25-cell unit is 106.0% higher than that of the 4-cell unit. Increasing the inlet temperature from 338 K to 343 K and 348 K reduces the complete melting time by 27.4% and 42.5% and increases the total stored heat by 14.6% and 26.9%, respectively. An inlet velocity of 0.01 m/s provides the best thermal charging performance, while further increases cause slight deterioration. Water performs best, although differences among the three HTFs remain small. These results provide a quantitative basis for honeycomb PCM storage-unit design.