Improving the performance of a dielectric barrier discharge plasma actuator (DBDPA) is required to further its practical use. In this study, the effects on DBDPA performance by the AC voltage waveform are experimentally investigated. For this purpose, we performed thrust measurements, consumption power measurements, and body force analysis using particle-image-velocimetry. Observations obtained using the basic symmetric waveforms yielded that changing the voltage gradient (dV/dt) like a sinusoidal waveform is effective to produce a strong body force with low consumption power. Therefore, we firstly propose the waveforms systematically composed of combinations of steep and gradual voltage slopes. In the investigation about proposed waveforms, we found that the negative steep-gradual voltage profile is effective for strong thrust induction, that is, the steep slope results in strong body force generation by a strong discharge, and the gradual slope maintains that body force. On the other hand, the effective positive-going voltage profile is different depending on the negative voltage profile. The positive steep-gradual profile works to induce body force with the same mechanism as the negative one, while the gradual-steep profile maintains the body force generated in the last negative-going voltage period and enhances the body force generated in the forthcoming negative-going voltage period. However, a positive-going voltage period itself generates only a weak body force independent from the voltage profiles. From the investigation, we found that a combination of the steep-gradual profile in both the negative- and positive-going voltage periods provides the strongest thrust generation. In addition, we further optimized the voltage waveform by changing the proportion of the negative-going voltage period in one AC cycle. We found that a waveform with a 70% negative-going voltage period achieves more than 40% stronger thrust and 20% higher efficiency than those of the sinusoidal waveform. Also, the waveform with an 80% negative-going voltage period yields over 35% stronger thrust with the highest efficiency, 25% higher than the sinusoidal waveform.
In this study, an experimental investigation of separation control using a dielectric barrier discharge plasma actuator was performed on an NACA0015 airfoil over a wide range of Reynolds numbers, angles of attack, and nondimensional burst frequencies. The range of the Reynolds number was based on a chord length ranging from 2.52 × 10 to 1.008 × 10. A plasma actuator was installed at the leading edge and driven by AC voltage. Burst mode (duty-cycle) actuation was applied, with the nondimensional burst frequency ranging between 0.1–30. The control authority was evaluated using the time-averaged distribution of the pressure coefficient and the calculated value of the lift coefficient . The baseline flow fields were classified into three types: (1) leading-edge separation; (2) trailing-edge separation; and (3) the hysteresis between (1) and (2). The results of the actuated cases show that the control trends clearly depend on the differences in the separation conditions. In leading-edge separation, actuation with a burst frequency of approximately 0.5 creates a wide negative pressure region on the suction-side surface, leading to an increase in the lift coefficient. In trailing-edge separation, several actuations alter the position of turbulent separation.
The well-known “ion wind” induced by a dielectric barrier discharge plasma actuator (DBD-PA) has been extensively used as an active flow control device in the boundary layer. Developing an accurate and efficient model for plasma-induced body force becomes the linchpin of the computational studies of DBD-PA-based flow control; both phenomenological and first-principle approaches have been largely investigated in the literature. In this research, a charged-particle model named Drift-Diffusion (D-D) model is employed to compute the body-force fields with ultra-high temporal resolution in a range of alternating voltage (peak-to-peak) from 7 kV to 20 kV. The analytical Suzen–Huang (S–H) model as an economical approach is also applied for comparison. Large-eddy simulations are employed to investigate the relationship between the DBD-PA-induced flow in quiescent air and the DBD-PA-controlled flow field over a stalled airfoil. The significance of body-force unsteadiness is well understood in the two flow fields by the model comparison. The results based on D-D model show good agreement with the corresponding experiments in both quiescent and separated flow fields, where the induced flow structure and separation control effect are carefully checked, respectively. As to the S–H model, the almost same magnitude but different location of the maximum wall-parallel induced velocity results in the stronger induced flow in quiescent field; however, the similar control effects in the separated flow. The present research provides a new approach to study the effect of DBD-PA-induced flow on separation control using the high-fidelity body-force field directly without any parametric calibration.
This study investigates the characteristics of flow-field patterns generated by burst-mode actuation of a dielectric-barrier-discharge plasma actuator in quiescent air. Particle-image velocimetry and background-oriented schlieren measurements conducted over a wide range of burst-signal parameters show that there are three types of flow-field patterns. Type 1 is the wall-surface jet seen in continuous mode actuation; type 2 features periodical independent vortices traveling along the wall surface; type 3 features such vortices moving away from the surface. The vortex sizes in types 2 and 3 are proportional to the energy consumed in generating one vortex. When the time-averaged jet velocity estimated by the power consumption is used as the characteristic velocity in the nondimensional scaling law, the time profiles of the vortex location in the type 3 flow-field pattern collapse into a single line, independently of the burst frequency and ratio. However, in the initial phase, the nondimensional vortex-core motion is better described using the jet velocity in continuous-mode actuation as the characteristic velocity. The transitions of the flow-field pattern from type 1 to type 3 result from interference between cyclically generated vortices and depend on the inter-vortex distances and the energy consumed in generating one vortex.
A discharge plasma simulation based on a three-fluid model is generally utilized to understand the physical mechanism in a dielectric barrier discharge (DBD) plasma actuator. In this study, the influence of chemical reactions considered in a numerical model on the simulation results is investigated from the viewpoint of electrohydrodynamic (EHD) force generation in the DBD plasma actuator. Positive and negative streamers are simulated utilizing three types of models considering different reactions and species, and the investigation is conducted in two steps. In the first step, where the influence of the neutralization process is investigated, the electron recombination with a cluster ion (O4+) plays an important role; it contributes to the decrease in seed electron production and effective coefficient of ionization for the positive streamer, and the decrease in negative ion production for the negative streamer; as a result, the propagation length and EHD force generation decrease. In the second step, where the influence of the production process is investigated, the stepwise ionization from metastable states has little influence owing to quite low production rates. Therefore, the simulation results indicate that the numerical model needs to consider the electron recombination with O4+ to accurately predict the streamer propagation and EHD force generation, while it is unnecessary to take into account the metastable molecules.
31 August 2021 in Measurement Science and Technology
Surface dielectric-barrier-discharge (DBD) is widely utilized for flow control actuators called DBD plasma actuator (DBDPA). With the aim of ensuring an accurate background-oriented schlieren (BOS) measurement of the near-surface density field in surface DBD, we investigate the effects of the depth of field (DoF), the wall surface and the background image deformation on measurement results. Experiments using a glass plate as the measurement target reveal that there is no appreciable effect of whether the DoF includes the measurement target. Additionally, the DoF should be shallow from the viewpoint of the error introduced by the wall surface. Moreover, it is found that the error introduced by the wall surface and the dot deformation can be characterized by specific dimensionless parameters. Finally, we conduct the BOS measurement of the DBDPA. We confirm that the density field is qualitatively valid from a physical respect, and we present the density field while discussing specific measurement errors.