Peter Havran

Dr. Peter Havran

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2022 in Energies
Verified
Journal Article
Open access
PDF file
PHPeter Havran
Peter Havran
RCRoman Cimbala
Roman Cimbala
JKJuraj Kurimský
Juraj Kurimský
Bystrík DolníkBystrík Dolník
Bystrík Dolník
IKIraida Kolcunová
Iraida Kolcunová
Ľuboš ŠárpatakyĽuboš Šárpataky
Ľuboš Šárpataky
The motivation to improve components in electric power equipment brings new proposals from world-renowned scientists to strengthen them in operation. An essential part of every electric power equipment is its insulation system, which must have the best possible parameters. The current problem with mineral oil replacement is investigating and testing other alternative electrical insulating liquids. In this paper, we present a comparison of mineral and hydrocarbon oil (liquefied gas) in terms of conductivity and relaxation mechanisms in the complex plane of the Cole-Cole diagram and dielectric losses. We perform the comparison using the method of dielectric relaxation spectroscopy in the frequency domain at different intensities of the time-varying electric field 0.5 kV/m, 5 kV/m, and 50 kV/m. With the increasing intensity of the time-varying electric field, there is a better approximation of the Debye behavior in all captured polarization processes of the investigated oils. By comparing the distribution of relaxation times, mineral oil shows closer characteristics to Debye relaxation. From the point of view of dielectric losses at the main frequency, hydrocarbon oil achieves better dielectric properties at all applied intensities of the time-varying electric field, which is very important for practical use.

1 July 2024 in Journal of Molecular Liquids
Verified
Journal Article
Closed access
PHPeter Havran
Peter Havran
RCRoman Cimbala
Roman Cimbala
Bystrík DolníkBystrík Dolník
Bystrík Dolník
MRMichal Rajnak
Michal Rajnak
RŠRóbert Štefko
Róbert Štefko
KPKatarína Paulovičová
Katarína Paulovičová

8 June 2023 in Journal of Materials Research and Technology
Verified
Journal Article
Open access
PHPeter Havran
Peter Havran
RCRoman Cimbala
Roman Cimbala
JKJuraj Kurimský
Juraj Kurimský
MRMichal Rajňák
Michal Rajňák
Bystrík DolníkBystrík Dolník
Bystrík Dolník
JKJozef Király
Jozef Király

11 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Bystrík DolníkBystrík Dolník
Bystrík Dolník
Ľuboš ŠárpatakyĽuboš Šárpataky
Ľuboš Šárpataky
IKIraida Kolcunová
Iraida Kolcunová
PHPeter Havran
Peter Havran
Insulators are one of the many components responsible for the reliability of electricity supply as part of transmission and distribution lines. Failure of the insulator can cause considerable economic problems that are much greater than the insulator cost. When the failure occurs on the transmission line, a large area can be without electricity supply or other transmission lines will be overloaded. Because of the consequences of the insulator’s failure, diagnostics of the insulator plays a significant role in the reliability of the power supply. Basic diagnostic methods require experienced personnel, and inspection requires moving in the field. New diagnostic methods require online measurement if it is possible. Diagnostic by measuring the leakage current flowing on the surface of the insulator is well known. However, many other quantities can be used as a good tool for diagnostics of insulators. We present in this article results obtained on the investigated porcelain insulators that are one of the most used insulation materials for housing the insulator’s core. Leakage current, dielectric loss factor, capacity, and electric charge are used as diagnostic quantities to investigate porcelain insulators in different pollution conditions and different ambient relative humidity. Pollution and humidity are the main factors that decrease the insulator´s electric strength and reliability.

15 November 2022 in Processes
Verified
Journal Article
Open access
PDF file
PHPeter Havran
Peter Havran
RCRoman Cimbala
Roman Cimbala
JKJozef Király
Jozef Király
MRMichal Rajnak
Michal Rajnak
SBSamuel Bucko
Samuel Bucko
Bystrík DolníkBystrík Dolník
Bystrík Dolník
Improving the dielectric properties of liquid-insulating materials is a current problem in research into the insulation system of a power transformer. Modern optimization of insulating liquids involves the potential use of unique synthetic esters enriched with nanoparticles. This study presents the results of the dielectric response of liquefied gas-based (GTL) insulating liquids during accelerated thermal aging. The dielectric relaxation spectroscopy method was used in the frequency domain to point out power losses as an imaginary part of a complex electric modulus. The relaxation spectra express the validity of applying this complex dielectric parameter. The polarization processes of the base oil alternately change position in the low-frequency band during thermal aging. Fullerene nanofluid undergoes three phases of dielectric loss changes during thermal aging. In the case of magnetic nanofluid, the effect of electric double-layer polarization disappeared after 500 h of thermal aging. It was found that with the gradual increase in the thermal aging time, there is no gradual increase in the dielectric losses investigated in the measured frequency spectrum. This study shows that the concentration of the two types of nanoparticles independently causes a different dielectric response to an applied AC electric field in the GTL base fluid.

1 September 2022 in Acta Electrotechnica et Informatica
Verified
Journal Article
Open access
PDF file
RŠRóbert Štefko
Róbert Štefko
MŠMiloš Šárpataky
Miloš Šárpataky
Ľuboš ŠárpatakyĽuboš Šárpataky
Ľuboš Šárpataky
VKVladimir Kohan
Vladimir Kohan
PHPeter Havran
Peter Havran
MKMichal Kolcun
Michal Kolcun
Further research and development in the field of microgrids and related modelling and testing will be necessary for successful application in practice, which will require various model elements. It will be possible to create near-real test microgrids to help better understand the behaviour of such grids. For this reason, it is necessary to develop elements of independent parts that appear in distribution networks that will experience conversion to microgrids in the future. Therefore, this article will describe and propose models of basic protection relays, whose potential for application in microgrids is high. The article will additionally provide models of some power supplies that will be found in such reconstructed new grids.