Iraida Kolcunová

Iraida Kolcunová


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2022 in Energies
Verified
Journal Article
Open access
PDF file
PHPeter Havran
Peter Havran
RCRoman Cimbala
Roman Cimbala
JKJuraj Kurimský
Juraj Kurimský
Bystrík DolníkBystrík Dolník
Bystrík Dolník
IKIraida Kolcunová
Iraida Kolcunová
Ľuboš ŠárpatakyĽuboš Šárpataky
Ľuboš Šárpataky
The motivation to improve components in electric power equipment brings new proposals from world-renowned scientists to strengthen them in operation. An essential part of every electric power equipment is its insulation system, which must have the best possible parameters. The current problem with mineral oil replacement is investigating and testing other alternative electrical insulating liquids. In this paper, we present a comparison of mineral and hydrocarbon oil (liquefied gas) in terms of conductivity and relaxation mechanisms in the complex plane of the Cole-Cole diagram and dielectric losses. We perform the comparison using the method of dielectric relaxation spectroscopy in the frequency domain at different intensities of the time-varying electric field 0.5 kV/m, 5 kV/m, and 50 kV/m. With the increasing intensity of the time-varying electric field, there is a better approximation of the Debye behavior in all captured polarization processes of the investigated oils. By comparing the distribution of relaxation times, mineral oil shows closer characteristics to Debye relaxation. From the point of view of dielectric losses at the main frequency, hydrocarbon oil achieves better dielectric properties at all applied intensities of the time-varying electric field, which is very important for practical use.

11 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Bystrík DolníkBystrík Dolník
Bystrík Dolník
Ľuboš ŠárpatakyĽuboš Šárpataky
Ľuboš Šárpataky
IKIraida Kolcunová
Iraida Kolcunová
PHPeter Havran
Peter Havran
Insulators are one of the many components responsible for the reliability of electricity supply as part of transmission and distribution lines. Failure of the insulator can cause considerable economic problems that are much greater than the insulator cost. When the failure occurs on the transmission line, a large area can be without electricity supply or other transmission lines will be overloaded. Because of the consequences of the insulator’s failure, diagnostics of the insulator plays a significant role in the reliability of the power supply. Basic diagnostic methods require experienced personnel, and inspection requires moving in the field. New diagnostic methods require online measurement if it is possible. Diagnostic by measuring the leakage current flowing on the surface of the insulator is well known. However, many other quantities can be used as a good tool for diagnostics of insulators. We present in this article results obtained on the investigated porcelain insulators that are one of the most used insulation materials for housing the insulator’s core. Leakage current, dielectric loss factor, capacity, and electric charge are used as diagnostic quantities to investigate porcelain insulators in different pollution conditions and different ambient relative humidity. Pollution and humidity are the main factors that decrease the insulator´s electric strength and reliability.

29 May 2019 in Energies
Verified
Journal Article
Open access
PDF file
MKMichal Krbal
Michal Krbal
LPLudek Pelikan
Ludek Pelikan
JSJaroslav Stepanek
Jaroslav Stepanek
JOJaroslava Orsagova
Jaroslava Orsagova
IKIraida Kolcunová
Iraida Kolcunová
This article offers an alternative method of calibrating partial discharge meters for research and teaching purposes. Most current modern calibrators are implemented as precise voltage pulse sources with a coupling capacitor. However, our calibrator is based on the physical principles of dielectric materials distributed in a plane or space. Calibrator design is unique and there is an attempt to get closer to the behavior of the measured real objects. The calibration impulses are created by energy from a high voltage power supply at the specific or nominal value of the applied voltage. At the same time, it is possible to simulate the value and quantity of the discharges and their position in the object relative to the input electrodes. The calibrator creates conditions as a real measured object with adjustable parameters. This paper describes a design of this type of calibrator, its implementation, numerical simulation of discharge values and laboratory measurements with functional verification using the Tettex 9520 calibrator and galvanic measured system DDX 7000/8003 and DDX 9121b. All measurements are carried out using the CVVOZEPowerLab Research Infrastructure equipment.