Tatiano Busatto

Dr. Tatiano Busatto

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
VRVineetha Ravindran
Vineetha Ravindran
TBTatiano Busatto
Tatiano Busatto
SRSarah Rönnberg
Sarah Rönnberg
JMJan Meyer
Jan Meyer
MBMath Bollen
Math Bollen
Widely existing circuit topologies and inverter control strategies for photovoltaic (PV) systems allow customer flexibility but also introduce different kinds of interharmonics into the grid. A complete understanding of interharmonics from PV systems, with reasons behind their origin, remains needed. In addition, the time-varying nature of interharmonics and the potential impacts on other equipment are yet to be understood. In this paper, laboratory and field measurements of seven different inverter types at multiple locations are presented. A comprehensive analysis is performed to understand the existence, persistence, and propagation of interharmonics in PV systems on the dc side as well as grid side for different power levels. The origins of the interharmonics are established with experimental evidence and through a comparative analysis. A rural low voltage six customer network, with two different impedance profiles caused by the installation of PV, is considered to show the potential impact on customer voltage. To address the time-varying nature of interharmonics, a sliding window ESPRIT method is preferred over fast fourier transform (FFT)-based methods.

1 July 2020 in Electric Power Systems Research
Verified
Journal Article
Closed access
ÁEÁngela Espín-Delgado
Ángela Espín-Delgado
SRSarah Rönnberg
Sarah Rönnberg
TBTatiano Busatto
Tatiano Busatto
VRVineetha Ravindran
Vineetha Ravindran
MBMath Bollen
Math Bollen

14 November 2018 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
TBTatiano Busatto
Tatiano Busatto
ALAnders Larsson
Anders Larsson
SRSarah Rönnberg
Sarah Rönnberg
MBMath Bollen
Math Bollen
A method is proposed in this paper to determine the harmonic impedances in low-voltage networks in a stochastic way. The consequences of resonances for harmonic propagation and stability of power converters are summarized. By using Monte Carlo simulation, the method includes the uncertainties in customer impedances, specifically due to electronic loads and local generation. The uncertainty in customer impedance is included by considering probability distribution for the resistive, inductive and capacitive parts of the impedance. The concept of transfer impedance is used for phase-to-neutral connections. A method is developed and applied to two existing low-voltage networks in Sweden. Results show that, for these two networks, the resonant frequencies decrease around 28 % once PV panels are installed. The paper includes a discussion of some of the practical aspects of applying the proposed method.

22 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
TBTatiano Busatto
Tatiano Busatto
SRSarah Rönnberg
Sarah Rönnberg
MBMath Bollen
Math Bollen
Harmonic modeling of low-voltage networks with many devices requires simple but accurate models. This paper investigates the advantages and drawbacks of such models to predict the current harmonics created by single-phase full-bridge rectifiers. An overview is given of the methods, limiting the focus to harmonic analysis. The error of each method, compared to an accurate numerical simulation model, is quantified in frequency and time domain considering realistic input scenarios, including background voltage distortion and different system impedances. The results of the comparison are used to discuss the applicability of the models depending on the harmonic studies scale and the required level of detail. It is concluded that all models have their applicability, but also limitations. From the simplest and fastest model, which does not require a numerical solution, to the more accurate one that allows discontinuous conduction mode to be included, the trade-off involves accuracy and computational complexity.

21 June 2023 in Energies
Verified
Journal Article
Open access
PDF file
SLShimi Sudha Letha
Shimi Sudha Letha
MBMath Bollen
Math Bollen
TBTatiano Busatto
Tatiano Busatto
ADAngela Espin Delgado
Angela Espin Delgado
EMEnock Mulenga
Enock Mulenga
VRVineetha Ravindran
Vineetha Ravindran
The journey towards sustainable transportation has significantly increased the grid penetration of electric vehicles (EV) around the world. The connection of EVs to the power grid poses a series of new challenges for network operators, such as network loading, voltage profile perturbation, voltage unbalance, and other power quality issues. This paper presents a coalescence of knowledge on the impact that electro-mobility can impose on the grid, and identifies gaps for further research. Further, the study investigates the impact of electric vehicle charging on the medium-voltage network and low-voltage distribution network, keeping in mind the role of network operators, utilities, and customers. From this, the impacts, challenges, and recommendations are summarized. This paper will be a valuable resource to research entities, industry professionals, and network operators, as a ready reference of all possible power quality challenges posed by electro-mobility on the distribution network.

7 July 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
NNNaser Nakhodchi
Naser Nakhodchi
MBMath Bollen
Math Bollen
TBTatiano Busatto
Tatiano Busatto
This paper presents the role of the medium-voltage network and low-voltage loads in harmonic voltages with low-voltage customers and harmonic propagation. A general model as well as a detailed transfer function-based model are used. By applying them to an existing network, it is shown that remote low-voltage loads have a significant impact on the source and transfer impedance. The main impact occurs for a specific range of frequencies below the resonant frequency of the low-voltage network. The general model is able to estimate this frequency range with an acceptable level of accuracy. Furthermore, by utilizing the concept of overall transfer impedance, it is shown that voltage harmonic levels for harmonic orders around this frequency range are determined mainly by aggregated remote emission rather than local emission.