Jens Goldschmidt

Mr. Jens Goldschmidt

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2018 in Sensors
Verified
Journal Article
Open access
PDF file
VSVincenz Sandfort
Vincenz Sandfort
JGJens Goldschmidt
Jens Goldschmidt
JWJürgen Wöllenstein
Jürgen Wöllenstein
Stefan PalzerStefan Palzer
Stefan Palzer
Comprehensive food chain management requires the monitoring of many parameters including temperature, humidity, and multiple gases. The latter is highly challenging because no low-cost technology for the simultaneous chemical analysis of multiple gaseous components currently exists. This contribution proposes the use of cavity enhanced Raman spectroscopy to enable online monitoring of all relevant components using a single laser source. A laboratory scale setup is presented and characterized in detail. Power enhancement of the pump light is achieved in an optical resonator with a Finesse exceeding 2500. A simulation for the light scattering behavior shows the influence of polarization on the spatial distribution of the Raman scattered light. The setup is also used to measure three relevant showcase gases to demonstrate the feasibility of the approach, including carbon dioxide, oxygen and ethene.

23 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JGJens Goldschmidt
Jens Goldschmidt
LNLeonard Nitzsche
Leonard Nitzsche
SWSebastian Wolf
Sebastian Wolf
ALArmin Lambrecht
Armin Lambrecht
JWJürgen Wöllenstein
Jürgen Wöllenstein
Infrared absorption spectroscopy is a widely used tool to quantify and monitor compositions of gases. The concentration information is often retrieved by fitting absorption profiles to the acquired spectra, utilizing spectroscopic databases. In complex gas matrices an expanded parameter space leads to long computation times of the fitting routines due to the increased number of spectral features that need to be computed for each iteration during the fit. This hinders the capability of real-time analysis of the gas matrix. Here, an artificial neural network (ANN) is employed for rapid prediction of gas concentrations in complex infrared absorption spectra composed of mixtures of CO and N2O. Experimental data is acquired with a mid-infrared dual frequency comb spectrometer. To circumvent the experimental collection of huge amounts of training data, the network is trained on synthetically generated spectra. The spectra are based on simulated absorption profiles making use of the HITRAN database. In addition, the spectrometer’s influence on the measured spectra is characterized and included in the synthetic training data generation. The ANN was tested on measured spectra and compared to a non-linear least squares fitting algorithm. An average evaluation time of 303 µs for a single measured spectrum was achieved. Coefficients of determination were 0.99997 for the predictions of N2O concentrations and 0.99987 for the predictions of CO concentrations, with uncertainties on the predicted concentrations between 0.04 and 0.18 ppm for 0 to 100 ppm N2O and between 0.05 and 0.18 ppm for 0 to 60 ppm CO.

10 December 2021 in TM - Technisches Messen
Verified
Journal Article
Closed access
LNLeonard Nitzsche
Leonard Nitzsche
JGJens Goldschmidt
Jens Goldschmidt
ALArmin Lambrecht
Armin Lambrecht
JWJürgen Wöllenstein
Jürgen Wöllenstein
A dual comb spectrometer is used as gas sensor for the parallel detection of nitrous oxide (N2O) and carbon monoxide (CO). These gases have overlapping absorption features in the mid-infrared (MIR) at a wavelength of 4.6 µm. With a spectra acquisition rate of 10 Hz, concentrations of 50 ppm N2O and 30 ppm CO are monitored with a relative precision of 6 × 10 − 3 and 3 × 10 − 3 respectively. The limit of detections are 91 ppb for N2O and 50 ppb for CO for an integration time of 25 s. The system exhibits a linear sensitivity from 2 ppm to 100 ppm with coefficients of determination of 0.99998 for N2O and 0.99996 for CO.

16 December 2025 in Analytical Chemistry
Verified
Journal Article
Open access
JGJens Goldschmidt
Jens Goldschmidt
NBNicolas Brugger
Nicolas Brugger
LNLeonard Nitzsche
Leonard Nitzsche
PNPonkanok Nitzsche
Ponkanok Nitzsche
CDCem Dinc
Cem Dinc
JWJürgen Wöllenstein
Jürgen Wöllenstein
We present a mid-infrared dual comb spectrometer for the precise determination of the isotopic ratio of the stable CO2 isotoplogues 12C16O2 and 13C16O2 under atmospheric pressure. The spectrometer is based on electro-optic intensity modulation at 1550 nm wavelength and subsequent wavelength flexible conversion to the mid-infrared. Here, the fundamental absorptions of CO2 in the ν3 band around 4.3 μm wavelength (2300 cm-1) were accessed to achieve the needed sensitivity to investigate the isotopic composition at atmospheric concentrations. The high spectral resolution of 0.004 cm-1 and spectral coverage of 8 cm-1 enable the measurements of the three most abundant CO2 isotopologues 12C16O2, 13C16O2 and 16O12C18O at ambient pressure. The high average signal-to-noise ratio per comb mode of 51 dB and a noise equivalent absorption coefficient of 5.4(9)·10-6 cm-1 Hz-1/2 ensures high precision. After an integration time of 172 s a precision on the stable isotopic ratio (δ13C) of <0.1‰ is achieved according to Allan deviation analysis. A linearity analysis on the measured concentrations of the single isotopologues results in coefficients of determination (R2) of 0.999 for CO2 concentrations ranging from 300 to 450 ppm, whereas for the measurement of δ13C-values ranging from -36.5‰ and -5.4‰ a coefficient of determination of 0.998 was achieved. This linear behavior and the high precision on the measurements demonstrate the great potential of the presented dual comb spectrometer for atmospheric research. Especially, where measurements under low pressure must be avoided, the here presented system is a promising alternative to established quantum cascade laser-based systems.

9 August 2023 in TM - Technisches Messen
Verified
Journal Article
Closed access
JGJens Goldschmidt
Jens Goldschmidt
EMElisabeth Moser
Elisabeth Moser
LNLeonard Nitzsche
Leonard Nitzsche
RBRudolf Bierl
Rudolf Bierl
JWJürgen Wöllenstein
Jürgen Wöllenstein
Artificial neural networks (ANNs) are used in quantitative infrared gas spectroscopy to predict concentrations on multi-component absorption spectra. Training of ANNs requires vast amounts of labelled training data which may be elaborate and time consuming to obtain. Additional data can be gained by the utilization of synthetically generated spectra, but at the cost of systematic deviations to measured data. Here, we present two approaches to train ANNs with a combination of comparatively small, measured data sets and synthetically generated data. For the first approach a neural network is trained hybridly with synthetically generated infrared absorption spectra of mixtures of N2O and CO and measured zero-gas spectra, taken with a mid-infrared dual comb spectrometer. This improves the mean absolute error (MAE) of the network predictions from 0.46 to 0.01 ppmV and 0.24 to 0.01 ppmV for the concentration predictions of N2O and CO respectively for zero-gas measurements which was previously observed for training with purely synthetic data. At the same time a similar performance on spectra from gas mixtures of 0–100 ppmV N2O and 0 to 60 ppmV CO was achieved. For the second approach an ANN pre-trained on synthetic infrared spectra of mixtures of acetone and ethanol is retrained on a small dataset consisting of 26 spectra taken with a mid-infrared photoacoustic spectrometer. In this case the MAE for the concentration predictions of ethanol and acetone are improved by 45 % and 20 % in comparison to purely synthetic training. This shows the capability of using synthetically generated data to train ANNs in combination with small amounts of measured data to further improve neural networks for gas sensing and the transferability between different sensing approaches.

1 January 2025
Verified
Conference Paper
Closed access
PDF file
JGJens Goldschmidt
Jens Goldschmidt
NBNicolas Brugger
Nicolas Brugger
JWJürgen Wöllenstein
Jürgen Wöllenstein
A dual comb spectrometer is presented to precisely detect the stable isotope ratio of 12CO2 and 13CO2 at atmospheric conditions and 4.375 µm wavelength. A precision on the δ13C value of 0.24‰ is achieved.