Armin Lambrecht

Dr. Armin Lambrecht


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2013 in The Analyst
Verified
Journal Article
Closed access
PDF file
ALArmin Lambrecht
Armin Lambrecht
MPMarcel Pfeifer
Marcel Pfeifer
WKWerner Konz
Werner Konz
JHJohannes Herbst
Johannes Herbst
FAFelix Axtmann
Felix Axtmann
Laser spectroscopy is a powerful tool for analyzing small molecules, i.e. in the gas phase. In the mid-infrared spectral region quantum cascade lasers (QCLs) have been established as the most frequently used laser radiation source. Spectroscopy of larger molecules in the gas phase, of complex mixtures, and analysis in the liquid phase requires a broader tuning range and is thus still the domain of Fourier transform infrared (FTIR) spectroscopy. However, the development of tunable external cavity (EC) QCLs is starting to change this situation. The main advantage of QCLs is their high spectral emission power that is enhanced by a factor of 104 compared with thermal light sources. Obviously, transmission measurements with EC-QCLs in strongly absorbing samples are feasible, which can hardly be measured by FTIR due to detector noise limitations. We show that the high power of EC-QCLs facilitates spectroscopy beyond simple absorption measurements. Starting from QCL experiments with liquid samples, we show results of fiber evanescent field analysis (FEFA) to detect pesticides in drinking water. FEFA is a special case of attenuated total reflection spectroscopy. Furthermore, powerful CW EC-QCLs enable fast vibrational circular dichroism (VCD) spectroscopy of chiral molecules in the liquid phase – a technique which is very time consuming with standard FTIR equipment. We present results obtained for the chiral compound 1,1′-bi-2-naphthol (BINOL). Finally, powerful CW EC-QCLs enable the application of laser photothermal emission spectroscopy (LPTES). We demonstrate this for a narrowband and broadband absorber in the gas phase. All three techniques have great potential for MIR process analytical applications.

1 July 2006 in Applied Spectroscopy
Verified
Journal Article
Closed access
PDF file
ALArmin Lambrecht
Armin Lambrecht
TBT. Beyer
T. Beyer
KHK. Hebestreit
K. Hebestreit
RMR. Mischler
R. Mischler
WPW. Petrich
W. Petrich
The application of mid-infrared laser spectroscopy to the reagent-free quantification of the concentration of glucose was investigated using cryogenically cooled lead salt lasers or, alternatively, quantum cascade lasers operating at room temperature. The concentration of glucose in aqueous solutions was quantified by means of fiber-based attenuated total reflection (ATR) spectroscopy (fiber-optical evanescent field analysis, FEFA) as well as fiber-based transmission spectroscopy. Both methods have the potential to be utilized by small fiber sensors, which can be inserted into the subcutaneous tissue in order to continuously measure the local concentration of glucose. In our in vitro experiments, noise-equivalent concentrations as low as 10 mg/dL were achieved. The midterm stability of the measurement schemes was investigated by means of Allan variance analysis. Based on the research presented in this manuscript, an all-room-temperature measurement scheme using quantum cascade lasers, miniaturized fiber-optic sensors, and pyroelectric detectors appears well suited for the continuous monitoring of glucose concentrations at physiological levels.

23 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JGJens Goldschmidt
Jens Goldschmidt
LNLeonard Nitzsche
Leonard Nitzsche
SWSebastian Wolf
Sebastian Wolf
ALArmin Lambrecht
Armin Lambrecht
JWJürgen Wöllenstein
Jürgen Wöllenstein
Infrared absorption spectroscopy is a widely used tool to quantify and monitor compositions of gases. The concentration information is often retrieved by fitting absorption profiles to the acquired spectra, utilizing spectroscopic databases. In complex gas matrices an expanded parameter space leads to long computation times of the fitting routines due to the increased number of spectral features that need to be computed for each iteration during the fit. This hinders the capability of real-time analysis of the gas matrix. Here, an artificial neural network (ANN) is employed for rapid prediction of gas concentrations in complex infrared absorption spectra composed of mixtures of CO and N2O. Experimental data is acquired with a mid-infrared dual frequency comb spectrometer. To circumvent the experimental collection of huge amounts of training data, the network is trained on synthetically generated spectra. The spectra are based on simulated absorption profiles making use of the HITRAN database. In addition, the spectrometer’s influence on the measured spectra is characterized and included in the synthetic training data generation. The ANN was tested on measured spectra and compared to a non-linear least squares fitting algorithm. An average evaluation time of 303 µs for a single measured spectrum was achieved. Coefficients of determination were 0.99997 for the predictions of N2O concentrations and 0.99987 for the predictions of CO concentrations, with uncertainties on the predicted concentrations between 0.04 and 0.18 ppm for 0 to 100 ppm N2O and between 0.05 and 0.18 ppm for 0 to 60 ppm CO.

26 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
GSGerrit Stiefvater
Gerrit Stiefvater
YHYvonne Hespos
Yvonne Hespos
DWDominic Wiedenmann
Dominic Wiedenmann
ALArmin Lambrecht
Armin Lambrecht
RBRaimund Brunner
Raimund Brunner
JWJürgen Wöllenstein
Jürgen Wöllenstein
Nitrous oxide (laughing gas, N2O) is a relevant greenhouse gas. Agriculture contributes significantly to its emissions. As nitrogen fertilization has been identified as one of the main sources of N2O, controlled application and reduction of the amount of fertilizer adapted to crop demand is essential to reduce N2O emissions. This requires detailed studies of the local distribution of the N2O emission fluxes on different croplands. Consequently, frequent spatially resolved field measurements of N2O concentrations are needed. A precision in the ppb range close to the ambient N2O level of 333 ppb is necessary. Tunable laser absorption spectroscopy using quantum-cascade lasers (QCL) as a light source is an established technique for the measurement of N2O traces. We present the development and validation of a compact portable setup for on-site measurement of N2O emissions from the soil. The setup differs from previous solutions by using an interband cascade laser (ICL), which has significantly lower power consumption compared to a QCL. The portable measurement setup allows N2O emission fluxes to be determined with a precision of 3.5% with a measuring duration of 10 min. The developed system enables the detection of increased N2O emissions because of the fertilization of fields. High N2O emission fluxes are indicators of the overfertilization of the field. Directly after fertilization, N2O fluxes between 2.9 and 5.3 µL m−2 min−1 depending on the gas acquisition site are measured during the field tests. Over time, the fluxes decrease. The obtained results compare well with data from more precise but also more complex and maintenance-intensive instruments for atmospheric research. With this system, the soil moisture as well as the air humidity and air temperature are recorded. Strong influences on N2O fluxes by soil moisture were observed. The presented measurement system is a contribution to the establishment of mobile N2O screening systems that are robust in the field and suitable for comprehensive and routine detection of N2O emissions from soil.

5 December 2017 in Sensors
Verified
Journal Article
Open access
PDF file
ALArmin Lambrecht
Armin Lambrecht
EMEric Maier
Eric Maier
HPHans-Fridtjof Pernau
Hans-Fridtjof Pernau
TSThomas Strahl
Thomas Strahl
JHJohannes Herbst
Johannes Herbst
Gas leak detection is an important issue in infrastructure monitoring and industrial production. In this context, infrared (IR) absorption spectroscopy is a major measurement method. It can be applied in an extractive or remote detection scheme. Tunable laser spectroscopy (TLS) instruments are able to detect CH4 leaks with column densities below 10 ppm·m from a distance of 30 m in less than a second. However, leak detection of non-IR absorbing gases such as N2 is not possible in this manner. Due to the fact that any leaking gas displaces or dilutes the surrounding background gas, an indirect detection is still possible. It is shown by sensitive TLS measurements of the ambient background concentration of O2 that N2 leaks can be localized with extractive and standoff methods for distances below 1 m. Minimum leak rates of 0.1 mbar·L/s were determined. Flow simulations confirm that the leakage gas typically effuses in a narrow jet. The sensitivity is mainly determined by ambient flow conditions. Compared to TLS detection of CH4 at 1651 nm, the indirect method using O2 at 761 nm is experimentally found to be less sensitive by a factor of 100. However, the well-established TLS of O2 may become a universal tool for rapid leakage screening of vessels that contain unknown or inexpensive gases, such as N2.

11 March 2016 in Chemie Ingenieur Technik
Verified
Journal Article
Closed access
PDF file
ALArmin Lambrecht
Armin Lambrecht
CBCarsten Bolwien
Carsten Bolwien
JHJohannes Herbst
Johannes Herbst
FKFrank Kühnemann
Frank Kühnemann
VSVincenz Sandfort
Vincenz Sandfort
SWSebastian Wolf
Sebastian Wolf