He Huang

Dr. He Huang


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2019 in Materials
Verified
Journal Article
Open access
PDF file
TWTengjiao Wang
Tengjiao Wang
JXjinyu Xu
jinyu Xu
CZCongjin Zhu
Congjin Zhu
HHHe Huang
He Huang
This study carried out tensile tests at definite elongation, tensile and shear tests on 4 admixture-modified styrene-acrylic emulsion-based cement composites (SECCs), and measured the strength, deformation, and energy consumption indexes of test specimens, so as to investigate the influences of coalescing agent, plasticizer, silane coupling agent, and nanometer aluminium oxide on the bond, tensile, and shear mechanical properties of the test specimens. Additionally, the Field Emission Scanning Electron Microscope (FE-SEM) test and Mercury Intrusion Porosimetry (MIP) test were conducted on the composite material specimens, to analyze the microscopic mechanism of different admixtures in modifying the mechanical properties of the SECC. The results suggested that the addition of coalescing agent, plasticizer, silane coupling agent, and nanometer aluminium oxide improved the bond, tensile and shear properties of the SECC specimens to various degrees. Of them, the coalescing agent promoted the mutual cross-linking of organic polymers with inorganic products, and optimized the transition interface to enhance the comprehensive mechanical properties of the test specimens; by contrast, nanometer aluminium oxide developed secondary hydration reaction with the inorganic products, and refined the pore structure to modify the mechanical properties of test specimens. Therefore, both of them achieved significant modification effects. Typically, the optimal bond properties of FFAMC, PLMC, SCAMC, and NAMC test specimens were achieved at the coalescing agent, plasticizer, silane coupling agent, and nanometer aluminium oxide addition amounts of 4%, 1.5%, 3%, and 1%, respectively. Besides, the improving effects of different admixtures on the tensile property of SECC specimens followed the order of coalescing agent > nanometer aluminium oxide > plasticizer > silane coupling agent, with the optimal addition amounts of 4%, 1.5%, 1%, and 2%, respectively. In addition, the improving effects of different admixtures on the shear performance of SECC specimens followed the order of coalescing agent > nanometer aluminium oxide > silane coupling agent > plasticizer, with the optimal addition amounts of 4%, 1.5%, 1%, and 1%, respectively.

12 August 2020 in Materials
Verified
Journal Article
Open access
PDF file
HCHaowen Chen
Haowen Chen
JXJinyu Xu
Jinyu Xu
YWYunquan Wu
Yunquan Wu
JLJunliang Liu
Junliang Liu
HHHe Huang
He Huang
In the cold belt area, the icing phenomenon often appears on the airport pavement, which affects the safety of aircraft take-off and landing. Microwave deicing technology can effectively solve this practical problem and has many advantages. Taking microwave deicing technology as the research object and the surface temperature of pavement concrete as the index, an open microwave test system has been established in this paper. Based on this system, the temperature distribution, variation rule, and influencing factors of concrete have been studied systematically. The results show that the surface temperature of concrete increases linearly due to microwave action. In addition, during the microwave action, the temperature increase of the concrete surface is centered on the center point and shows a stepwise decreasing trend along the radius. At the same time, the increase of microwave source height leads to the increase of surface temperature distribution uniformity. The surface ice affects the rate of temperature increase of concrete in stages under microwave action, and the surface edge area remains frozen for a certain period of time. The temperature distribution of concrete surface is a decisive factor affecting the degree of ice removal, and the concrete surface will generate residual heat after the microwave action ends. This phenomenon can delay the regression of the temperature distribution of the concrete surface, thus effectively preventing the re-freezing of the ice layer.

1 May 2019 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
HHHe Huang
He Huang
JXJin-Yu Xu
Jin-Yu Xu
Magnetite aggregate is used as a absorbing material. In order to study the mechanical properties, absorbing heat and deicing efficiency and frost resistance of magnetite concrete, I prepared the magnetite aggregate concrete with 0, 20%, 40%, 60%, 80% and 100% magnetite content, which be used to measure the compressive strength, flexural strength and surface temperature rise curve of magnetite aggregate concrete under microwave irradiation. The results show that the addition of magnetite aggregate can effectively improve the mechanical properties and deicing efficiency of concrete. With the increase of magnetite aggregate, the compressive strength and flexural strength increase gradually, and is approximately linear with the content of magnetite aggregate. With the increase of magnetite aggregate, the absorption and heating efficiency of magnetite aggregate concrete increases gradually. When the content of magnetite aggregate reached 100%, the efficiency of absorbing heat and deicing increased by 71.3% and 69.7% respectively.

30 May 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HHHe Huang
He Huang
JXJinyu Xu
Jinyu Xu
AYao Yao
ao Yao
WXWei Xia
Wei Xia
EBErlei Bai
Erlei Bai
YNYIPENG NING
YIPENG NING
To explore the law of microwave deicing of carbon-fiber-modified concrete under the action of multiple factors and improve its application in pavement, in this study, we designed a test of the heat absorption and deicing effect of concrete under the action of multiple factors. We found that the law of heat absorption and deicing of CFRP is influenced by the coupling effect of fiber length and dosage, height (straight-line distance between the microwave receiving surface and bell component), initial temperature and ice cover. The temperature rises fastest when the fiber dosage is 0.2% and fiber length is 6 mm without ice. Further analysis of other factors shows that the deicing effect is optimal when the height is 40 mm, and the presence of ice on fiber-reinforced concrete weakens the microwave deicing efficiency, although the reduction is small. The test results of these two factors are in agreement with the simulation results and conform to expectations. The initial temperature has a considerable influence on the deicing efficiency. In practical applications, the deicing time should be adjusted according to the initial temperature in order to prevent the phenomenon of secondary icing when the heating time is too long. Based on heat generation and heat dissipation, the four stages of microwave deicing were analyzed, and the relationship with the temperature increase rate was deduced. It was proven that carbon fiber affected the deicing efficiency by changing the microwave absorption and reflection effect of concrete.

12 May 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AYao Yao
ao Yao
JXJinyu Xu
Jinyu Xu
WXWei Xia
Wei Xia
HHHe Huang
He Huang
YNYIPENG NING
YIPENG NING
In order to explore the impact compression performance of aluminum oxide fiber concrete, the impact compression test of aluminum oxide fiber concrete with different contents is carried out by using the split Hopkinson pressure bar (SHPB) comprehensive test system with a diameter of 100 mm. Our intent was to explore the influence law of different contents of aluminum oxide fiber on the impact compression performance of concrete matrixes, and to optimize and establish a constitutive model based on damage theory and stress residue. The results show that adding alumina short-cut fiber to concrete changes its mechanical properties of impact compression to a certain extent. When the volume content of fiber is 0.2%, the characteristics of strength, deformation, and energy are the best, and the excess aluminum oxide fiber reduces the original performance due to agglomeration and other factors; the strength characteristics, peak deformation characteristics, and energy characteristics of aluminum oxide fiber concrete are significantly affected by strain rate and impact velocity. Based on the Zhu-Wang-Tang non-linear viscoelastic model (ZWT model), the complexity coefficient is optimized and the residual stress term is added to construct the prediction model of aluminum oxide fiber concrete. The parameters in the model have a good prediction effect on the stress-strain curve under different strain rates.

29 December 2021 in Research Square
Verified
Preprint
Open access
PDF file
HHHe Huang
He Huang
JXJinyu Xu
Jinyu Xu
JLJunliang Liu
Junliang Liu
HCHaowen Chen
Haowen Chen
In this paper, the airport pavement concrete has been taken as the main research object, three kinds of absorbing materials, namely silicon carbide (SiC), iron oxide (Fe3O4) and graphite, have been respectively mixed into the concrete, and an open microwave testing system has been established. Based on this system, the basic mechanical properties, microwave heating characteristics, microwave deicing effect and its influencing factors of modified concrete are systematically studied. In addition, a comparative analysis of the influence mechanism of different absorbing materials on the strength and absorbing performance of pavement concrete is carried out. The results showed that the addition of SiC, Fe3O4, and graphite could effectively enhance the microwave effect of pavement concrete, and the more the addition, the more obvious the improvement. Furthermore, under the same mixing amount, the degree of improvement of microwave deicing performance of each absorbing material from large to small is graphite, Fe3O4, SiC. However, the addition of graphite will form several weak links in concrete, thereby reducing its overall mechanical properties. SiC can slightly improve the mechanical properties of pavement concrete, but it has no significant effect on the microwave absorption properties. With the addition of Fe3O4, the strength of concrete changes little, and the effect of microwave absorbing heating and microwave deicing is remarkable. In general, the comprehensive performance of microwave deicing of Fe3O4 modified concrete is optimal. This study has high scientific and practical significance, and can be widely applied to deicing projects on airports and high-grade highways.