Colton Myers

Mr. Colton Myers

Restek Corporation

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2020 in Separations
Verified
Journal Article
Open access
PDF file
JHJason Herrington
Jason Herrington
GGGerman Gomez
German Gomez
CMColton Myers
Colton Myers
GSGary Stidsen
Gary Stidsen
DBDavid Bell
David Bell
Thirty years since the invention and public disclosure of solid phase microextraction (SPME), the technology continues evolving and inspiring several other green extraction technologies amenable for the collection of small molecules present in complex matrices. In this manuscript, we review the fundamental and operational aspects of a novel SPME geometry that can be used to “hunt” target molecules in complex matrices: the SPME Arrow. In addition, a series of applications in environmental, food, cannabis and forensic analysis are succinctly covered. Finally, special emphasis is placed on novel interfaces to analytical instrumentation, as well as recent developments in coating materials for the SPME Arrow.

1 April 2021 in Frontiers in Chemistry
Verified
Journal Article
Open access
PDF file
CMColton Myers
Colton Myers
JHJason S. Herrington
Jason S. Herrington
PHPaul Hamrah
Paul Hamrah
KAKelsey Anderson
Kelsey Anderson
The cannabis market is expanding exponentially in the United States. As state-wide legalization increases, so do demands for analytical testing methodologies. One of the main tests conducted on cannabis products is the analysis for terpenes. This research focused on implementation of accelerated solvent extraction (ASE), utilizing surrogate matrix matching, and evaluation of traditional vs. more modern sample introduction techniques for analyzing terpenes via gas chromatography–mass spectrometry (GC-MS). Introduction techniques included Headspace-Syringe (HS-Syringe), HS-Solid Phase Microextraction Arrow (HS-SPME Arrow), Direct Immersion-SPME Arrow (DI-SPME Arrow), and Liquid Injection-Syringe (LI-Syringe). The LI-Syringe approach was deemed the most straightforward and robust method with terpene working ranges of 0.04–5.12 μg/mL; r2 values of 0.988–0.996 (0.993 average); limit of quantitation values of 0.017–0.129 μg/mL (0.047 average); analytical precisions of 2.58–9.64% RSD (1.56 average); overall ASE-LI-Syringe-GC-MS method precisions of 1.73–14.6% RSD (4.97 average); and % recoveries of 84.6–98.9% (90.2 average) for the 23 terpenes of interest. Sample workflows and results are discussed, with an evaluation of the advantages/limitations of each approach and opportunities for future work.

23 November 2021 in Separations
Verified
Journal Article
Open access
PDF file
DPDhananjay I. Patel
Dhananjay I. Patel
TRTuhin Roychowdhury
Tuhin Roychowdhury
CJCollin Jacobsen
Collin Jacobsen
CMColton Myers
Colton Myers
JHJason Herrington
Jason Herrington
MLMatthew Linford
Matthew Linford
We report the first fabrication of sputtered carbon, solid-phase microextraction (SPME) fibers. These fibers have competitive extraction capabilities compared with the commercial carbon wide range (CWR) SPME fiber. This report also includes a demonstration of a newly developed SPME test mix that includes 15 different compounds with a wide range of functional groups and chemical properties. The fiber fabrication process involves sputtering carbon onto fused silica fibers, and the effects of throw distance on the morphology of the carbon coatings were studied. Four different carbon coating thicknesses were evaluated, with PDMS added as a stationary phase. These fibers were characterized with multiple analytical techniques, including scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), water contact angle (WCA) goniometry, as well as headspace (HS) and direct immersion (DI)–SPME–GC–MS. The best (11.5 µm) sputtered carbon SPME fibers, with and without PDMS, were evaluated using the new evaluation mix and compared with the commercial CWR fiber and a previously sputtered/developed silicon fiber. The new probe mix helped elucidate differences among the fibers, which would have been missed by current commercial test mixes. The sputtered carbon SPME fibers showed similar functional group selectivity as commercial CWR fibers. However, the sputtered carbon fibers showed higher responses per volume compared with the commercial CWR fiber, indicating the porous morphology of the sputtered carbon has the ability to overcome large phase thickness/volume discrepancies and increase the relative recovery for various compounds.