César Félix Cayo-Rojas

Prof. Dr. César Félix Cayo-Rojas

Universidad Privada San Juan Bautista, Lima, Peru
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2022 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
AGAndrea Gaviria-Martinez
Andrea Gaviria-Martinez
LCLeonor Castro-Ramirez
Leonor Castro-Ramirez
MCMARYSELA IRENE LADERA CASTAÑEDA
MARYSELA IRENE LADERA CASTAÑEDA
Luis Adolfo CervantesLuis Adolfo Cervantes
Luis Adolfo Cervantes
HCHernán Cachay-Criado
Hernán Cachay-Criado
César Félix Cayo-RojasCésar Félix Cayo-Rojas
César Félix Cayo-Rojas
Background: It has been demonstrated that dental restorations with rough surfaces can have several disadvantages such as pigment retention or plaque accumulation, which can facilitate caries formation, color variation, loss of brightness, degradation of restoration, among others. The present study aimed to assess surface roughness in bulk fill and conventional nanohybrid resins with and without polishing, controlling the oxygen inhibited layer. Methods: This in vitro and longitudinal experimental study consisted of 120 resin blocks of 6 mm diameter and 4 mm depth, divided into two groups: Bulk Fill (Tetric® N-Ceram Bulk-fill, Opus Bulk Fill APS, Filtek™ Bulk Fill) and conventional nanohybrid (Tetric® N-Ceram, Opallis EA2, Filtek™ Z250 XT). Each resin group was divided into two equal parts, placing glycerin only on one of them, in order to control the oxygen inhibited layer. Subsequently, the surface roughness was measured before and after the polishing procedure with Sof-Lex discs. The data were analyzed with the T-test for related measures, and for comparison between groups before and after polishing, the non-parametric Kruskal Wallis test with the Bonferroni post hoc was used, considering a significance level of p < 0.05. Results: Before polishing, the resin composites with the lowest surface roughness were Opus Bulk Fill APS (0.383 ± 0.186 µm) and Opallis EA2 (0.430 ± 0. 177 µm) with and without oxygen inhibited layer control, respectively; while after polishing, those with the lowest surface roughness were Opus Bulk Fill APS (0.213 ± 0.214 µm) and Tetric N-Ceram (0.097 ± 0.099 µm), with and without oxygen inhibited layer control, respectively. Furthermore, before and after polishing, all resins significantly decreased their surface roughness (p < 0.05) except Opus Bulk Fill APS resin with oxygen inhibited layer control (p = 0.125). However, when comparing this decrease among all groups, no significant differences were observed (p < 0.05). Conclusion: The Opus Bulk Fill APS resin with oxygen inhibited layer control presented lower surface roughness both before and after polishing, being these values similar at both times. However, after polishing the other bulk fill and conventional nanohybrid resins with and without oxygen inhibited layer control, the surface roughness decreased significantly in all groups, being this decrease similar in all of them.

28 July 2022 in Polymers
Verified
Journal Article
Open access
PDF file
ACAnn Carrillo-Marcos
Ann Carrillo-Marcos
GSGiuliany Salazar-Correa
Giuliany Salazar-Correa
LCLeonor Castro-Ramirez
Leonor Castro-Ramirez
MCMARYSELA IRENE LADERA CASTAÑEDA
MARYSELA IRENE LADERA CASTAÑEDA
CLCarlos López-Gurreonero
Carlos López-Gurreonero
César Félix Cayo-RojasCésar Félix Cayo-Rojas
César Félix Cayo-Rojas
The aim of this study was to assess the microhardness and surface roughness of bulk-fill resin composites treated with and without the application of an oxygen-inhibited layer (OIL) and a polishing system. This in vitro experimental study consisted of 72 resin composite blocks divided into three groups: Tetric N-Ceram Bulk Fill, Opus Bulk Fill APS, and Filtek Bulk Fill. Each resin composite group was further divided into two subgroups: with and without OIL control. Subsequently, surface roughness and microhardness were measured before and after polishing. A t-test was used to compare independent and related measures. For the intergroup comparison of variation before and after polishing, the Kruskal–Wallis test with Bonferroni post hoc was used considering a significance level of p < 0.05. When comparing surface roughness, significant differences were observed between Opus Bulk Fill resin composite with and without OIL control (p = 0.003) before polishing. The same occurred when comparing Tetric N-Ceram resin composite with and without OIL control (p = 0.039) after polishing. In addition, the surface roughness of Filtek Bulk Fill, Opus Bulk Fill, and Tetric N-Ceram Bulk Fill resin composites, with and without OIL control, decreased significantly after polishing (p < 0.001), while surface microhardness significantly increased (p < 0.05), with the exception of Opus Bulk Fill resin with OIL control (p = 0.413). In conclusion, OIL control and polishing significantly improved the surface roughness and surface microhardness of Filtek Bulk Fill and Tetric N-Ceram Bulk Fill resin composites. However, in the case of Opus Bulk Fill resin composite, only its surface roughness was significantly improved.

4 December 2021 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
César Félix Cayo-RojasCésar Félix Cayo-Rojas
César Félix Cayo-Rojas
KHKaren K. Hernández-Caba
Karen K. Hernández-Caba
AAAna S. Aliaga-Mariñas
Ana S. Aliaga-Mariñas
MCMARYSELA IRENE LADERA CASTAÑEDA
MARYSELA IRENE LADERA CASTAÑEDA
Luis Adolfo CervantesLuis Adolfo Cervantes
Luis Adolfo Cervantes
Background: The contraction presented by resin composites causes an increase in stress at the tooth-resin interface, causing micro-gaps that allow microleakage. This study aims to evaluate the degree of in vitro marginal microleakage in class II restorations with two bulk fill resin composites compared to a conventional nanohybrid resin composite. Methods: The present study was an in vitro experimental design. A total of 30 standardized class II cavities were prepared in 15 human molars (mesially and distally). These cavities were later distributed in 3 groups according to the type of resin. Groups A and B were restored with bulk fill resin composites (Filtek—3 M/ESPE and Tetric N-Ceram—Ivoclar/Vivadent respectively) in a single increment of 4 mm. Group C was restored with the Filtek Z350 XT – 3 M/ESPE resin composite and two increments of 2 mm. Later, the restorations were subjected to 10,000 thermocycles between 5 °C to 55 °C and immersed in a silver nitrate solution (1 M for 24 h). The crowns were then sectioned mesiodistally and observed under the stereomicroscope to determine the degree of marginal microleakage at the occlusal and cervical areas. The results were analyzed with the Kruskal–Wallis and the Mann–Whitney U statistical tests. Results: There were no statistically significant differences regarding the degree of microleakage between the three types of resin composites in the occlusal and cervical areas (p > 0.05). Similarly, there were no significant differences after comparing each resin type in its occlusal and cervical area (p > 0.05). Conclusion: Filtek Bulk Fill and Tetric N-Ceram Bulk Fill resin composites showed no statistically significant differences with the conventional nanohybrid resin composite Filtek Z350XT at both occlusal and cervical areas.

1 March 2021 in Journal of International Society of Preventive and Community Dentistry
Verified
Journal Article
Open access
GRGiovanna Gisella Ramírez-Vargas
Giovanna Gisella Ramírez-Vargas
JMJulia Elbia Medina Y Mendoza
Julia Elbia Medina Y Mendoza
AAAna Sixtina Aliaga-Mariñas
Ana Sixtina Aliaga-Mariñas
MLMarysela Irene Ladera-Castañeda
Marysela Irene Ladera-Castañeda
LCLuis Adolfo Cervantes-Ganoza
Luis Adolfo Cervantes-Ganoza
César Félix Cayo-RojasCésar Félix Cayo-Rojas
César Félix Cayo-Rojas
The use of bleaching agents, despite being a conservative treatment, can cause a decrease in the surface microhardness of dental resins, affecting their aesthetics and performance. The aim of this study was to evaluate the in vitro effect of polishing on the surface microhardness of nanohybrid composite resins that were subjected to bleaching with 35% hydrogen peroxide. This cross-sectional, in vitro experimental study consisted of 30 composite resin samples made according to ISO 4049-2019 and divided equally into two groups (A and B) which were subjected to 35% hydrogen peroxide bleaching. Group A was subjected to polishing procedure, whereas group B was the control group. The samples were stored in distilled water at 37°C for 24 h. The Vickers microhardness was determined with a load of 100 g-f for 10 s. The data were analyzed with Student’s t-test for independent samples at a confidence level of 95%. The surface microhardness of the group that was subjected to polishing (A) obtained a mean of 78.07 ± 7.96 HV, whereas for the group that was not subjected to polishing (B) the mean was 65.67 ± 5.22 HV. The difference between groups (A and B) was statistically significant (P < 0.001). Nanohybrid composite resins previously subjected to 35% hydrogen peroxide gel significantly increased their surface microhardness when subjected to polishing when compared with unpolished nanohybrid composite resins.

11 May 2024 in International Dental Journal
Verified
Journal Article
Open access
FSFlor Santander-Rengifo
Flor Santander-Rengifo
CCCarmen Martin Carreras-Presas
Carmen Martin Carreras-Presas
RARosa Aroste-Andía
Rosa Aroste-Andía
EHEmily Hernández-Huamaní
Emily Hernández-Huamaní
PGPercy Gavilán-Chávez
Percy Gavilán-Chávez
César Félix Cayo-RojasCésar Félix Cayo-Rojas
César Félix Cayo-Rojas
The aim of this study was to compare the microtensile bond strength (µTBS) and failure mode of 4 different universal adhesive systems (UAs) on human dentin. The study sectioned the occlusal thirds of 32 human third molars and divided them into 4 groups based on the adhesive system used. Group A: Palfique Universal Bond, Group B: Single Bond Universal, Group C: All-Bond Universal, and Group D: One Coat 7 Universal. The specimens underwent a 10,000-cycle thermocycling ageing process prior to testing (n = 32). Afterwards, 8 beams were obtained per group and subjected to µTBS testing using a digital universal testing machine at a speed of 1 mm/min. The microtensile bond strength values were analysed in Megapascals (MPa), and the failure mode was evaluated using a stereomicroscope. Welch's parametric ANOVA with robust variance and the Games-Howell post hoc test were used for µTBS comparisons, and Fisher's exact test was used to determine the association between adhesive type and failure mode. The significance level was set at P < .05. Group D showed a significantly higher µTBS than groups A (P < .001) and B (P < .001), but no significant difference was observed with group C (P= .075). Furthermore, groups B and C showed significantly higher µTBS than group A (P< .001 and P < .001, respectively), but there was no significant difference between groups B and C (P = .132). Additionally, group A exhibited a significant association with an adhesive failure mode (P < .05), whereas groups B, C, and D were significantly associated with a mixed failure mode (P < .05). The One Coat 7 Universal adhesive system showed higher microtensile bond strength values and higher chemical interaction with dentin compared to Palfique Universal Bond and Single Bond Universal. However, no significant differences were observed compared to All-Bond Universal.

22 December 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
JZJorge Zamudio-Santiago
Jorge Zamudio-Santiago
MCMARYSELA IRENE LADERA CASTAÑEDA
MARYSELA IRENE LADERA CASTAÑEDA
Flor Magaly SantanderFlor Magaly Santander
Flor Magaly Santander
CLCarlos López-Gurreonero
Carlos López-Gurreonero
ACAlberto Cornejo-Pinto
Alberto Cornejo-Pinto
César Félix Cayo-RojasCésar Félix Cayo-Rojas
César Félix Cayo-Rojas
Background: Activated charcoal is a nanocrystalline form of carbon with a large specific surface area and high porosity in the nanometer range, having consequently the capacity to absorb pigments, chromophores, and stains responsible for tooth color change, while carbamide peroxide is unstable and breaks down immediately upon contact with tissue and saliva, first dissociating into hydrogen peroxide and urea and subsequently into oxygen, water, and carbon dioxide. Therefore, the aim of the present study was to assess the effect of 16% carbamide peroxide and activated-charcoal-based whitening toothpaste on enamel surface roughness in bovine teeth. Materials and Methods: The present experimental in vitro, longitudinal, and prospective study consisted of 60 teeth randomly distributed in six groups: A: artificial saliva, B: conventional toothpaste (Colgate Maximum Protection), C: whitening toothpaste with activated charcoal (Oral-B 3D White Mineral Clear), D: 16% carbamide peroxide (Whiteness Perfect 16%), E: 16% carbamide peroxide plus conventional toothpaste (Whiteness Perfect 16% plus Colgate Maximum Protection), and F: 16% carbamide peroxide plus whitening toothpaste with activated charcoal (Whiteness Perfect 16% plus Oral-B 3D White Mineral Clear). Surface roughness was assessed with a digital roughness meter before and after each treatment. For the statistical analysis, Student’s t test for related samples was used, in addition to the ANOVA test for one intergroup factor, considering a significance level of p < 0.05. Results: The surface roughness variation of bovine tooth enamel, before and after application of bleaching agent, was higher in groups of whitening toothpaste with activated charcoal (0.200 µm, Confidence Interval (CI): 0.105; 0.296 µm) and 16% carbamide peroxide plus whitening toothpaste with activated charcoal (0.201 µm, (CI): 0.092; 0.309 µm). In addition, bovine teeth treated with conventional toothpaste (p = 0.041), whitening toothpaste with activated charcoal (p = 0.001), and 16% carbamide peroxide plus whitening toothpaste with activated charcoal (p = 0.002) significantly increased their surface roughness values. On the other hand, significant differences were observed when comparing the variation in surface roughness between the application of artificial saliva (control) and the whitening toothpaste with activated charcoal (p = 0.031), and the 16% carbamide peroxide plus whitening toothpaste with activated charcoal (p = 0.030). Conclusion: The use of whitening toothpaste with activated charcoal and in combination with 16% carbamide peroxide significantly increased enamel surface roughness in bovine teeth.